Varilight V-PRO SMART SUPLA Скачать руководство пользователя страница 1

INSTRUCTIONS FOR VARILIGHT  
V

-

PRO SMART SUPLA DIMMER SWITCHES 

 

OVERVIEW  

Thank you for choosing a VARILIGHT V

-

Pro Smart intelligent 

programmable rotary/Wi

-

Fi control dimmer switch.  

IMPORTANT:

 Read ALL sections below before installing this dimmer 

switch. 
The V

-

Pro Smart dimmer is suitable for 1

-

way circuits. For 2 or 3

-

Way 

circuits, use a V

-

Pro Smart dimmer with one or more companion 

controllers. V

-

Pro Smart rotary/Wi

-

Fi dimmers cannot be used in 

conjunction with conventional switches in a 2

-

way circuit. Use only on 

an electricity supply of 230V~. 
This product complies with 

European Safety Regulations

 (IEC 669

-

2

-

or BSEN60669

-

2

-

1) when used in lighting circuits containing MCBs 

(miniature circuit breakers). These can be rated at 6A, 10A or 16A 
(preferably 6A for lighting circuits). Your guarantee is not affected if you 
have an older lighting circuit protected by fuse wire links. 

Doyle & Tratt Products Ltd

, Carylls Lea, Faygate, Horsham, 

West Sussex, RH12 4SJ, UK. +44 (0)1293 223333

 

Varilight Europe Kft

, 2600 Vác, Althann Mihály Frigyes utca 2, 

Hungary.

 

 

LOADING 

Maximum loads for V

-

Pro Smart Supla dimmer switches (please see 

www.varilight.co.uk for latest loading advice); 

Always observe the recommended maximum load. 

Dimmer 

Series 

Lighting  
Load 

V

-

Pro Smart Supla 

Max. Load Per Gang 

Dimmable Mains 
& Low Voltage 
LEDs  

1 to 10 Dimmable LEDs (max. 100W) 

Check your LED lamps are suitable for use with 

dimmers that have a standby mode. A load 

regulator may be required, e.g. Varilight Glowfix

 

 

THIS SWITCH IS SUITABLE FOR 

 

Most dimmable LEDs

 

 

THIS SWITCH IS NOT SUITABLE FOR: 

 Non

-

dimmable fluorescent bulbs and tubes; 

 Wire

-

wound or toroidal transformers;  

 Electric 

motors 

 

OVERLOAD PROTECTION: 

This dimmer switch is protected against overload. If an overload occurs 
it will automatically turn off until the overload is removed and the dimmer 
switch is switched off and then switched back on again. However, if the 
dimmer switch receives a total short

-

circuit it may be damaged beyond 

repair. 
 

TRANSFORMERS

  

Use only with quality dimmable 

electronic

 transformers. For optimum 

performance choose VARILIGHT transformers*.  
To calculate load, add the VA ratings of the 

transformers 

(

not 

the

 

wattage of the bulbs).  Choose transformers with a maximum rating 
close to their lamp load (eg. Use a 50VA, 60VA or 70VA transformer to 
control a 50W low voltage bulb).N.B. Certain transformers 

may not 

behave according to their power rating when used with a dimmer

An overload will result in the dimmer turning itself off. If this happens, 
change your transformer(s) (VARILIGHT transformer(s) 
recommended); or remove one (or some) transformer(s) from the 
circuit; or choose a higher rated dimmer instead.

 

If a transformer 

specifies Triac dimming, use a dimmer from the V

-

Com series. 

If a transformer appears as a highly inductive load, e.g. Wire

-

wound 

or toroidal transformers, the dimmer will not work. To protect itself it will 
turn off within 1 second.  

ADVICE ON CHANGING LIGHT BULBS 

Always turn off the mains power when light bulbs controlled by your 
V

-

Pro Smart dimmers are replaced. If you change the type of light bulb 

then restore factory settings as described under “Programming”. 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

FREQUENTLY ASKED QUESTIONS 

For FAQs, please visit: www.varilight.co.uk/faqs

  

 

GUARANTEE 

In case of any defect, return the dimmer to our service department. 
Varilight undertakes to repair or replace, at its discretion, goods which 
have become defective within one year of purchase, solely as a result 
of faulty materials and workmanship, provided that:

-

  

a) The unit has been correctly fitted according to the instructions and 
has not been used with an incompatible load, fluorescent tubes, or 
overloaded beyond its rating, and has only been used on a 200

-

250V 

a.c. power supply.  
b) The dimmer module has not been tampered with or taken apart.  
c) The unit is securely packed and safely returned to either address 
listed in the overview section above, together with a letter stating the 
guarantee registration number below, the date and place of purchase, 
your contact details and return address, the type and wattage of the 
lighting or other load being controlled and the details of the fault. This 
guarantee states Varilight’s entire liability, which does not extend to 
cover consequential loss or damage or installation costs arising from a 
defective product.  The guarantee does not apply to problems arising 
from any incompatibility between your lamps and the dimmer switch. 
This guarantee does not in any way affect the statutory rights of the 
purchaser and is offered so that you may have the benefit of our 
technical facilities. 
In many cases products don’t need replacing, so for further information 
and help with troubleshooting, see our FAQ page at 

www.varilight.co.uk/faqs

, or contact our Customer Services by calling 

+44 (0)1293 223333 or create a support ticket at 

www.varilight.co.uk/help

.    

GUARANTEE REGISTRATION NUMBER SM005 
 

FITTING YOUR DIMMER SWITCH 

Read the instructions below carefully. Incorrect installation may damage 
the dimmer beyond repair. In case of any doubt or difficulty consult a 
qualified electrician. 
1. Switch off at the mains, then remove the existing switch and 
disconnect the wiring from the switch terminals at the rear, taking note 
of the present wiring of the switch and the marking on the terminals. 
Where there are two or more wires together in the old switch, they must 
be kept together in the dimmer switch.  
2. Ensure that any wall box is free of plaster lumps or projecting screw 
heads. Dimmer switches on single

-

sized plates can be fitted to wall 

boxes having 60.3mm screw fixing centres and those with double

-

sized 

plates to wall boxes with 120.6mm fixing centres. Dimmers can be fitted 
into a box with a minimum depth of 25mm for Classic plated products, 
or 35mm for Ultraflat and Screwless. A box having 4 fixing lugs cannot 
be used without modifying it. The top and bottom lugs must be broken 
off or bent flat.  
3. To connect the wiring for 1

-

way or 2

-

way circuits refer to the wiring 

diagrams, or the text under the heading "1

-

Way, 2

-

Way and 3

-

Way 

Circuits" on the other side of this leaflet. Take care that no bare wires 
project out of the terminals. Keep wires together in a terminal if they were 
together in your old switch.  
4. Dimmer switches having a metal plate must be earthed by means of 
the earthing point on the faceplate.  
5. After connecting the wires screw the dimmer switch gently into the 
wall box so that the front plate is not distorted or cracked. Do not trap 
the wiring between the rear of the dimmer and the back of the wall box.  
6. Once installation is complete. Switch on the mains supply and switch 
on the dimmer.  

Important:

 Disconnect the dimmer before carrying out insulation 

resistance testing. Failing to do so could damage a dimmer and make 
the guarantee invalid.  

 

www.varilight.co.uk 

J_SM

 

Please 

record the batch number

 printed on 

the side of the plastic moulding on the rear of 
the product. This will assist us in providing any 
technical support you may require. 

Reg. SM005 

BATCH NO: 

INSTALLERS

 – Please leave these instructions with your customer 

for future reference. 

WARNING

: Do not apply products with metal faceplates directly to 

freshly plastered or damp surfaces as product may tarnish. If in 
doubt, use polythene as a temporary gasket to protect the product. 
Do not use masking tape on metal faceplates.  

Отзывы: