Model 990 dCLD II Component Leak Detector
1-5
1.4 Cables
All cables necessary to power the control unit and to connect the control unit to the turbo
spec tube assembly have been provided. The cables have been customized to the length
you specified at the time of your order. Section 3, “Setup and Operations via the
Rear Panel” includes details about the connections. Part numbers are included in
Section 5.7 “Spare Parts List” on page 5-23.
❑
Power Cable
−
Connects to main power.
❑
37-pin Cal Leak Valve Block Cable
−
Connects to the cal leak valve block for
calibrated leak operation.
❑
Turbo Spec Tube Cable
−
Connects to the turbo spec tube assembly. It ends with the
spectrometer tube block connector (spec tube block connector), the turbo cooling
fan, and the connector for the turbo pump power input.
❑
Turbo Pump Cable
−
Connects from the spec tube block connector to the turbo
pump. It provides power to the turbo pump.
❑
14-pin Display I/O Cable
−
Connects to the optional front control panel when it is
remotely located. This cable is supplied with the optional front control panel.
1.5 Mating Connectors
A kit containing mating connectors and pins for building cables for connections J3, J4 and
J6 is supplied with your 990 dCLD II. Build the cables according to the tables included in
Appendix B “Customer Accessible Inputs and Outputs”.
1.6 Optional Front Control Panel
The Model 990 dCLD II Optional Front Control Panel provides indication of the leak rate
measurement and spectrometer pressure through bar graph displays, and control of the leak
detector via control buttons and a touch screen panel. The optional front control panel can
be mounted remotely from the control unit or directly onto its front face.
Once the 990 dCLD II is set up, calibrated and put into production, control is turned over
to the PLC or host computer when PARALLEL ENABLE is asserted. Control remains with
the PLC or host computer until that control is specifically released by de-asserting PARAL-
LEL ENABLE. However, during operation you can use the optional front control panel to
monitor leak rate, pressure and operating parameters.
Section 4, “Setup and Monitor Operations via the Optional Front Control Panel”, of this
manual provides a detailed description of the optional front control panel, a discussion of
the bar graph and pressure displays, and details of the touch screen display and how to use
the menus provided to set up and monitor the 990 dCLD II.
Содержание 990 dCLD II
Страница 4: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank D R A F T 4 2 0 0 7 ...
Страница 12: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank ...
Страница 50: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank ...
Страница 128: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank ...
Страница 146: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank ...
Страница 160: ...Model 990 dCLD II Component Leak Detector This page intentionally left blank ...
Страница 161: ......