Configure -> LED Modes -> LED Correction (Must be turned ON) -> Field Adj
Step 3. Using UP and DOWN arrow keys, select parameter to adjust.
Step 4. Using LEFT and RIGHT arrow keys, adjust parameter.
Step 5. Repeats Steps 3 and 4 as desired for each parameter until preferred color is achieved.
IMPORTANT!
Pressing ESC (escape) while in this menu will automatically store the adjusted
values with the LED correction. When LED Correction is turned
ON
, any adjustments you’ve made
will be reflected. To return back to the factory calibration, simply adjust the R, G, B, and D back to the
values of 65535.
Manual Color Adjustment Through a Control Console
The other way to manipulate the color adjustment is via the control console. After making sure color
calibration is ON and all RED, Green, Blue and Intensity channels are set to 100%, set control channel
(23 in Mode 1, 41 in Mode 2) to a DMX value of 121-122, hold value for at least 3 seconds, then give
a DMX value of 0. This will set the fixture into a color calibration "adjustment mode".
While in Adjustment Mode, modify Red, Green, Blue and/or Dimmer channels to desired color/
intensity. Once color is determined, set control channel to a DMX value of 124-125, hold for at least 3
seconds, then give a DMX value of 0. This will store the values into the color calibration.
IMPORTANT NOTES:
•
After the value of "0" is given during control console adjustment, the color or output of the fixture
- as the user has adjusted it - will suddenly change. If the user returns Red, Green, Blue, and/or
Dimmer values for the luminaire back to full from the desk, the fixture will then match the color
(s) and/or intensity values that they have adjusted.
•
Any adjustments to the calibration that have been made through the menu system or via the control
channel may be viewed via the adjustment window on the luminaire itself as values of less than
65535 on the display bars for each of the four parameters. Values of less than 100% on any of
these parameters indicate that a manual adjustment has been performed on the fixture and stored.
•
To return back to the factory calibration, simply adjust the R, G, B, and D back to the values of
65535.
Содержание VLX3
Страница 1: ......
Страница 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Страница 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Страница 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Страница 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Страница 97: ......