![Varec 2500 Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/varec/2500/2500_installation-and-operation-manual_3495994109.webp)
Varec, Inc.
99
Chapter 9
Troubleshooting
Friction is a common problem that affects gauge accuracy. Some liquids produce corrosion in
the mechanism. Periodic inspection and maintenance provided by a Varec service contract can
prevent problems from occurring. Periodic cleaning, lubrication, and replacement of worn
parts stops trouble before it starts.
Dials Do Not Respond When Gauge Check Knob is
Rotated
Caution
Broken negator spring may cause injury. Stand clear of gauge head when remov-
ing back cover.
Possible Cause
Action
1
Tape broken?
Yes -
• Replace tape.
• Check attachment of negator motor to storage sheave.
• Check for damaged gauge parts.
No -
• Go to 2.
2
Negator motor broken?
Yes -
• Replace negator.
• Do not redrill or repair.
• Wear gloves.
• Check tape condition.
• Check for damaged gauge parts.
No -
• Go to 3.
3
Tape rewound?
Yes -
• Tape detached from float.
• Replace tape and re-attach.
• Check for damaged gauge parts.
No -
• Go to 4.
Содержание 2500
Страница 2: ......
Страница 6: ...vi Installation and Operations Manual...
Страница 10: ...2500 Automatic Tank Gauge 10 Installation and Operation Manual...
Страница 16: ...2500 Automatic Tank Gauge 6 Installation and Operations Manual...
Страница 66: ...2500 Automatic Tank Gauge 56 Installation and Operations Manual...
Страница 68: ...2500 Automatic Tank Gauge 58 Installation and Operations Manual...
Страница 108: ...2500 Automatic Tank Gauge 98 Installation and Operations Manual...
Страница 112: ...2500 Automatic Tank Gauge 102 Installation and Operations Manual...
Страница 118: ...2500 Automatic Tank Gauge 108 Installation and Operations Manual...
Страница 123: ......