VLC5501 Vapormatic Immobiliser Installation Manual                                                    

8 of 21

 

   

Immobiliser blocker module wiring diagram without relays: 

(Up to 12 

Amp continuous current draw)

 

Both immobiliser blockers must be installed.

  

The keypad sends a signal to both immobiliser blockers, if one is not installed the other will not work.  When only one circuit is 
being blocked, the spare secondary blocker wires marked (7), should be taped up and insulated out of harms way. 

If power to the immobiliser blockers decays below 8 Volts power to the blockers will be lost, resulting in the vehicle not 
starting. 

 

 

Earth wire (-):

 Must be firmly secured to the vehicle’s chasses.  

 

Power wire (+):

 Must be connected to an ignition live via a 3 Amp fuse supplied. Example: when the ignition is 

switched off the blocker feed wire marked (+) must be at 0 voltage. With the ignition in the ‘ON’ position the blocker 
feed wire marked (+) must receive between 8 to 16 Volts D.C.  

NOTE:  Please read “Start Position” below. 

 

 

Blocking wires (7):

 Two wires are marked with (7), these are used as a continuity break (blocking circuit). 

 

Ignition off:

       

No  power  to  the  two  immobiliser  blockers  or  keypad.    The  contacts  inside  the  immobiliser  blockers  are  

normally closed (N/C), therefore when the ignition is switched off the blocker allows continuity through 
the two wires marked (7).   

Ignition 

on:  

When the ignition is switched on the immobiliser blockers become live and instantly open the contacts 
breaking the continuity through wires marked (7), thus breaking the circuit. 

Authorisation: 

When the immobiliser blockers receive a confirmation signal from the Keypad or Keypad Override Disc, 
the immobiliser blockers switch off, therefore restoring the power supply and allowing the vehicle to start. 

Start position: 

With the ignition in the start position the voltage supply to the blocker feed wire marked (+) must not 
decay below 8 volts when the engine is cranking.   

Some ignition circuits are not live when the ignition 

key is in the start position, if the voltage decays below 8 Volts, the blockers will drop out causing the 
vehicle not to start.

 

Fuse Holders: 

 The Fuse holders supplied are of a special automotive anti-vibration type, therefore each fuse is held tighter than 

normal. 

Important!!!  Please read all of this section carefully:

 

NOTE: Maximum 12 Amp current draw on blocking circuit. If the 
current draw exceeds 12A you must use 30 Amp relays supplied. 

NOTE: For installations where only one circuit is being blocked, 
tape up wires marked (7) for ‘blocking circuit 2’.  Secondary 
immobiliser blocker must be wired in for the system to work 
correctly. 

*******

An ignition (switchable) live feed & a chassis earth are 

required. Both the earth (-) & positive (+) wires to the blockers 
must have a secure joint. This will limit any continuity issues 
for the units use. If either wire has a loose or high resistance 
joint, the unit may be re-energized which could cause the 
blocked  circuit  to  fail  &  the  vehicle  to  become 

immobilized.

******

 

Содержание VLC5501

Страница 1: ...LC5501 Immobiliser installation manual Installation manual Version 2 4 ____________________________________ Attention Installation of this security product is additional protection for your vehicle bu...

Страница 2: ...VLC5501 Vapormatic Immobiliser Installation Manual 2 of 21...

Страница 3: ...s 7 Immobiliser blocker module wiring diagram without relays Upto 12 Amp continuous current draw 8 Immobiliser blocker module wiring diagram with relays 9 Keypad installation 10 Mounting of the Keypad...

Страница 4: ...lified Agricultural Technician If you have any concerns with fitting this immobiliser you should seek professional advice by taking it to your local authorised vehicle dealer The vehicles battery shou...

Страница 5: ...ing plate 3 Mounting plate screws x 4 4 Immobiliser blockers x 2 5 Keypad Override Disc 6 Keypad Override Disc battery 7 30 Amp relays 8 30 Amp relay wiring looms 9 In line fuse holders x 3 10 3 Amp f...

Страница 6: ...feeds from this position Breaking these two lines are normally sufficient to knock out dash ignition and all CAN devices including the ECU engine controller Ensuring that engine starting is impossibl...

Страница 7: ...ower consumption of the electrical circuit being re routed through the Vapormatic blockers the continuous current draw must not exceed 12 Amps Also the length of the wires and their cross sectional ar...

Страница 8: ...ckers become live and instantly open the contacts breaking the continuity through wires marked 7 thus breaking the circuit Authorisation When the immobiliser blockers receive a confirmation signal fro...

Страница 9: ...ive anti vibration type therefore each fuse is held tighter than normal Example Ignition off No power to the two blockers or keypad The contacts inside the immobiliser blockers are normally closed N C...

Страница 10: ...important it should be placed in an easy to see and use position with no obstructions The desired location must have sufficient room behind to accommodate the four screws and keypad wiring Using the...

Страница 11: ...ne of the three in line fuse holders supplied Attention For convenience the keypad power can be run off of the ignition Auxiliary line as long as it is 0 voltage with the ignition turned off When the...

Страница 12: ...herefore be kept on your person at all times Note This disc device operates within a 5 metre range it transmits a signal every 20 seconds Therefore once the ignition is switched on it may take up to 2...

Страница 13: ...ard power strip 6 Turn the ignition ON 7 Wait until you hear a double beep emitted from the keypad and the green LED switches ON This can take up to 20 seconds 8 Try to start the engine If the engine...

Страница 14: ...obiliser blockers sticker on outer casing and the Keypad Override Disc Sticker on PCB board 2 Red keypad LED not lighting up with ignition switched on Check keypad in line fuse Check 8 to 16V supply c...

Страница 15: ...n person Check all wiring for good connections Check chassis earth Test blockers normally closed with no power open with power 6 Immobiliser not working 30 amp relays in circuit engine starts with out...

Страница 16: ...r name Value Operating frequency 2 4GHz Operating range 5 metres Operating voltage 8 16V Current consumption 100mA Maximal load to blocking circuit 15A 12 Amp continuous Operating temperature 40 85 C...

Страница 17: ...onditions of Sale 2 Prices and Payment i All prices UK and Export are subject to adjustment without notice The contract price shall be the price current at the date of despatch of the goods ii In the...

Страница 18: ...ise agreed risk of loss or damage to the goods shall pass to the Buyer when the goods are handed to the carrier for delivery to the Buyer Subject thereto where goods are to be carried at the cost of t...

Страница 19: ...d as a result of any breach of the contract by the Buyer c Until the Company has received full payment of all the sums due to the Company from the Buyer provided always that the Buyer continues to tra...

Страница 20: ...e stated in the Company s current catalogue ii Whilst specifications are considered to be correct at the date of printing the Company reserves the right to change specifications of the goods and their...

Страница 21: ...ms of these Conditions of Sale are in lieu of all warranties conditions terms undertakings and obligations implied by statute common law custom trade usage course or dealing or otherwise all of which...

Отзывы: