background image

 

 

 

VLC5501 Vapormatic Immobiliser Installation Manual                                                    

16 of 21

 

 

Technical parameters: 

Keypad module: 

Parameter name 

Value 

Operating frequency 

2,4GHz 

Operating range 

5 metres 

Operating voltage 

8-16V 

Current consumption 

120mA 

Operating temperature 

-40.....+85 C 

Dimensions 

72x52x13mm 

 

Blocking modules: 

Parameter name 

Value 

Operating frequency 

2,4GHz 

Operating range 

5 metres 

Operating voltage 

8-16V 

Current consumption 

100mA 

Maximal load to blocking circuit 

15A (12 Amp continuous) 

Operating temperature 

-40.....+85 C 

Dimensions 

69x29x9mm 

 

Keypad Override Disc: 

Parameter name 

Value 

Operating frequency 

2,4GHz 

Operating range 

5 metres 

Battery type 

CR2430 

Battery life 

12 months 

Operating temperature 

-30.....+85 C 

Dimensions 

49x41x6 mm 

 

 

Additional relays: 

Parameter name 

Value 

Operating voltage 

12V 

Maximal current draw 

30A 

 

 

Содержание VLC5501

Страница 1: ...LC5501 Immobiliser installation manual Installation manual Version 2 4 ____________________________________ Attention Installation of this security product is additional protection for your vehicle bu...

Страница 2: ...VLC5501 Vapormatic Immobiliser Installation Manual 2 of 21...

Страница 3: ...s 7 Immobiliser blocker module wiring diagram without relays Upto 12 Amp continuous current draw 8 Immobiliser blocker module wiring diagram with relays 9 Keypad installation 10 Mounting of the Keypad...

Страница 4: ...lified Agricultural Technician If you have any concerns with fitting this immobiliser you should seek professional advice by taking it to your local authorised vehicle dealer The vehicles battery shou...

Страница 5: ...ing plate 3 Mounting plate screws x 4 4 Immobiliser blockers x 2 5 Keypad Override Disc 6 Keypad Override Disc battery 7 30 Amp relays 8 30 Amp relay wiring looms 9 In line fuse holders x 3 10 3 Amp f...

Страница 6: ...feeds from this position Breaking these two lines are normally sufficient to knock out dash ignition and all CAN devices including the ECU engine controller Ensuring that engine starting is impossibl...

Страница 7: ...ower consumption of the electrical circuit being re routed through the Vapormatic blockers the continuous current draw must not exceed 12 Amps Also the length of the wires and their cross sectional ar...

Страница 8: ...ckers become live and instantly open the contacts breaking the continuity through wires marked 7 thus breaking the circuit Authorisation When the immobiliser blockers receive a confirmation signal fro...

Страница 9: ...ive anti vibration type therefore each fuse is held tighter than normal Example Ignition off No power to the two blockers or keypad The contacts inside the immobiliser blockers are normally closed N C...

Страница 10: ...important it should be placed in an easy to see and use position with no obstructions The desired location must have sufficient room behind to accommodate the four screws and keypad wiring Using the...

Страница 11: ...ne of the three in line fuse holders supplied Attention For convenience the keypad power can be run off of the ignition Auxiliary line as long as it is 0 voltage with the ignition turned off When the...

Страница 12: ...herefore be kept on your person at all times Note This disc device operates within a 5 metre range it transmits a signal every 20 seconds Therefore once the ignition is switched on it may take up to 2...

Страница 13: ...ard power strip 6 Turn the ignition ON 7 Wait until you hear a double beep emitted from the keypad and the green LED switches ON This can take up to 20 seconds 8 Try to start the engine If the engine...

Страница 14: ...obiliser blockers sticker on outer casing and the Keypad Override Disc Sticker on PCB board 2 Red keypad LED not lighting up with ignition switched on Check keypad in line fuse Check 8 to 16V supply c...

Страница 15: ...n person Check all wiring for good connections Check chassis earth Test blockers normally closed with no power open with power 6 Immobiliser not working 30 amp relays in circuit engine starts with out...

Страница 16: ...r name Value Operating frequency 2 4GHz Operating range 5 metres Operating voltage 8 16V Current consumption 100mA Maximal load to blocking circuit 15A 12 Amp continuous Operating temperature 40 85 C...

Страница 17: ...onditions of Sale 2 Prices and Payment i All prices UK and Export are subject to adjustment without notice The contract price shall be the price current at the date of despatch of the goods ii In the...

Страница 18: ...ise agreed risk of loss or damage to the goods shall pass to the Buyer when the goods are handed to the carrier for delivery to the Buyer Subject thereto where goods are to be carried at the cost of t...

Страница 19: ...d as a result of any breach of the contract by the Buyer c Until the Company has received full payment of all the sums due to the Company from the Buyer provided always that the Buyer continues to tra...

Страница 20: ...e stated in the Company s current catalogue ii Whilst specifications are considered to be correct at the date of printing the Company reserves the right to change specifications of the goods and their...

Страница 21: ...ms of these Conditions of Sale are in lieu of all warranties conditions terms undertakings and obligations implied by statute common law custom trade usage course or dealing or otherwise all of which...

Отзывы: