Vantron TMC Series Скачать руководство пользователя страница 1

Vantron 

| Embedded in your success, Embedded in your better life

 

World-leading provider of embedded/IoT products and solutions 

TMC Series | User Manual      

 

   

 

 

 

   

           

www.vantrontech.com

 

 

 
 
 

TMC Series Medical-grade Touch Monitors 

 
 
 
 
 
 
 
 
 
 

User Manual 

 

Version: 1.0 

 

 
 

 

 

 

 

 

 

© Chengdu Vantron Technology Co., Ltd. All rights reserved.

Содержание TMC Series

Страница 1: ... in your better life World leading provider of embedded IoT products and solutions TMC Series User Manual www vantrontech com TMC Series Medical grade Touch Monitors User Manual Version 1 0 Chengdu Vantron Technology Co Ltd All rights reserved ...

Страница 2: ...our success Embedded in your better life World leading provider of embedded IoT products and solutions TMC Series User Manual www vantrontech com Revision History No Version Description Date 1 V1 0 First release Nov 9 2022 ...

Страница 3: ...CHAPTER 1 INTRODUCTION 5 1 1 Product Overview 6 1 2 Packaging List 7 1 3 Specifications 8 1 4 Product Layout 9 1 5 Installation Connection 10 CHAPTER 2 GETTING STARTED 12 2 1 Operation 13 2 1 1 Power 13 2 1 2 Touch 13 2 1 3 Video 13 2 1 4 On screen Display OSD 14 2 2 Troubleshooting 14 CHAPTER 3 DISPOSAL AND WARRANTY 15 3 1 Disposal 16 3 2 Warranty 17 Appendix Regulatory Compliance Statements 18 ...

Страница 4: ... product features and specifications contained herein at any time without prior notice An up to date version of this manual is available at www vantrontech com The trademarks in this manual registered or not are properties of their respective owners Under no circumstances shall any part of this user manual be copied reproduced translated or sold This manual is not intended to be altered or used fo...

Страница 5: ...logy Inc Address 48434 Milmont Drive Fremont CA 94538 Tel 650 422 3128 Email sales vantrontech com China Office Chengdu Vantron Technology Co Ltd Address 6th Floor 1st Building No 9 3rd WuKe East Street WuHou District Chengdu P R China 610045 Tel 86 28 8512 3930 3931 8515 7572 6320 Email sales vantrontech com cn Regulatory Information The Product is designed to comply with China Compulsory Certifi...

Страница 6: ...ll for future reference Do not disassemble or otherwise modify the Product Such action may cause heat generation ignition electronic shock or other damages including human injury and may void your warranty Keep away from heat source such as heater heat dissipater or engine casing Do not insert foreign materials into the openings of the Product as it may cause the Product to malfunction or burn out...

Страница 7: ... electronic components unless with a dust collector Power off and contact Vantron technical support engineer in case of the following faults The Product is damaged The temperature is excessively high Fault is still not solved after troubleshooting according to this manual Do not use in combustible and explosive environment Keep away from combustible and explosive environment Keep away from all ene...

Страница 8: ...Vantron Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions TMC Series User Manual 5 www vantrontech com CHAPTER 1 INTRODUCTION ...

Страница 9: ...ements of application in different scenarios in particular in the medical health area The TMC series features quick response time large active area and viewing angle to optimize the display performance The screen is designed to be anti fingerprint and users have the option to equip the touch screen with anti glare and anti reflection coatings that offer excellent visual experience and improve huma...

Страница 10: ...should you find anything damaged or missing please contact your sales representative in due time Accessories Touch monitor Power adapter power cable USB cable HDMI cable VGA cable DP cable DP cable applicable only to TMC215 and TMC270 Actual accessories might vary slightly from the list above as the customer order might differ from the standard configuration options The plastic film will protect t...

Страница 11: ...d glass Optional Anti glare Anti reflection Light transmittance ratio 85 Touch communication interface USB 2 0 Video Video interface 1 x HDMI 1 x VGA 1 x DP Exclusive for TMC215 TMC270 Audio Audio interface 1 x Line out Optional Mechanical Dimensions Please refer to the datasheet of the specific model Weight Please refer to the datasheet of the specific model Installation VESA mount 100mm x 100mm ...

Страница 12: ...w vantrontech com 1 4 Product Layout Drawings for illustration only the diagonal sizes and I Os vary with device models 75mm x 75mm VESA pattern applies only to TMC156 while the other three models are provided with 100mm x 100mm VESA pattern DC in USB 2 0 OSD controls see below VESA 75mm x75mm 100mm x 100mm HDMI Power Select Menu Up Down Line out VGA ...

Страница 13: ...TMC 190 TMC 215 TMC270 Such touch monitors are designed to be mounted onto a variety of stands arms walls or medical charts with the VESA patterns on the back which comprise 75mm x 75mm and 100mm x 100mm 2 Connect the video input interface of the touch monitor and the video source with the HDMI VGA DP cable s DP port is exclusive for TMC215 TMC270 The display cable shall vary with the interface to...

Страница 14: ... to enable the touch control 4 Plug in the audio cable if needed The audio interface is provided as per requirement of the customer 5 Connect a 12V DC power supply to the power jack of the touch monitor and the LED indicator will turn solid red to get into the sleep mode 6 Wait about 2 3 seconds and the LED indicator will turn solid green if the PC master device connected to functions properly 7 P...

Страница 15: ...Vantron Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions TMC Series User Manual 12 www vantrontech com CHAPTER 2 GETTING STARTED ...

Страница 16: ...ter device connected to functions properly To turn off the touch monitor users just need to press the power button once The relationship between the power indicator and the touch monitor is as follows Indicator status Touch monitor status OFF OFF Solid red SLEEP Solid green WORKING 2 1 2 Touch The touch monitor is factory calibrated and does not require manual calibration 2 1 3 Video Generally the...

Страница 17: ... touch monitor If the problem is not covered here or the problem persists after troubleshooting please contact your sales representative as indicated in Technical Support and Assistance in the Foreword 1 The touchscreen display does NOT respond when turning on the system Check if the DC power adaptor is properly connected and functions well 2 The touch monitor is dim Use the OSD control keys to ad...

Страница 18: ...Vantron Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions TMC Series User Manual 15 www vantrontech com CHAPTER 3 DISPOSAL AND WARRANTY ...

Страница 19: ...sposal in conformity with local regulations Please ensure that the abandoned batteries are disposed of according to local regulations on waste disposal Do not throw batteries into fire or put in common waste canister as they are explosive Products or product packages labeled with the sign of explosive should not be disposed of like household waste but delivered to specialized electrical electronic...

Страница 20: ...e CUSTOMER for non warranty repair VANTRON will provide this service as long as the components are available in the market and the CUSTOMER is requested to place a purchase order up front Parts repaired will have an extended warranty of 3 months Returned Products Any Product found to be defective and covered under warranty pursuant to Clause above shall be returned to VANTRON only upon the CUSTOME...

Страница 21: ...t does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to...

Страница 22: ...tropically radiated power e i r p is not more than that necessary for successful communication Le présent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 Le dispositif ne doit pas produire de brouillage préjudiciable et 2 Ce dispositif doit accepter tout brouillage reçu y compris un brouillage susc...

Страница 23: ... s label which means that the equipment has been tested to the following Directives and Standards This equipment has been tested to the requirements for the CE Marking as required by EMC Directive 2014 30 EU and the Low Voltage Directive 2014 35 EU Notice to Users in the European Union Use only the provided power cords and interconnecting cabling provided with the equipment Substitution of provide...

Страница 24: ...components or ESDS circuitries While touching ESDS components or circuits personnel should be properly grounded There is no plastic foam or vinyl allowed in static protected workstations Heat Related Concerns The Product may become very warm during normal use It complies with the user accessible surface temperature limits defined by the International Standards for Safety Still sustained contact wi...