Vantron
| Embedded in your success, Embedded in your better life
World-leading provider of embedded/IoT products and solutions
DE20-BT Industrial DTU | User Manual
25
3.4
Exploring More Functions with the Vantron Dtool
The Vantron Dtool offers users an easy way to configure and monitor the device. All the
changes or settings will take effect upon device reboot.
3.4.1
Status
Under the Status menu, information available is as follows:
•
Connection Status;
•
Device Information (device model, serial number, firmware version, device running
time, and reboot information);
•
Physical Layer information (LTE module information, SIM card information, data
transmitted and received);
•
Network Layer information (network mode, data transmitted and received);
•
Application Layer information (application center status);
3.4.2
Configuration
Under the Configuration menu, users can configure or change the settings of the serial
communication port, the connection with Bluetooth sensors, and settings of the network,
DTU working mode, and data center.
•
Serial Port: variables are available from the drop-down lists;
Parameter
Description
Default value
Mode
Serial port mode
RS485
Speed
Baud rate (in bps)
115200
Character size
Data bit
8
Parity
None/Odd/Even
None
Stop bit
1/2
1
Flow control
None/Request to send (RTS)/Clear to
Send (CTS)
None
Every time before you change the serial mode of the device in the Vantron Dtool,
please remember to change the pin connection beforehand. Restart the device before
applying the settings.