Vantage Hearth RadioLink INTERPOINT-RTSS Скачать руководство пользователя страница 1

©Vantage, 8/18/2016 / IS-0616-B 

RadioLink® InterPoint RTS — MODEL: INTERPOINT-RTSS 

page 1 of 3 

I N S T A L L A T I O N 

 

V A N T A G E C O N T R O L S . C O M  

V A N T A G E   I N S T A L L   G U I D E S

 

2168 West Grove Parkway, Suite 300, Pleasant Grove, UT.  84062   USA 
Telephone:  801 229-2800 

 Fax:  801 224-0355 

RadioLink

®

 InterPoint RTS — MODEL: INTERPOINT-RTSS

 

 

Overview 
Vantage’s RadioLink™ InterPoint RTS Station provides an 
interface between InFusion™ Design Center™ systems and 
Somfy® RTS motors. Each RTSS supports up to 255 unique 
addresses, effectively controlling 255 blinds or groups of 
blinds. RTS motors are available for control of a variety of 
window coverings. InterPoint technology allows window 
coverings to be opened/closed and stopped at the press of a 
button with no direct wiring needed. The RTSS plugs into any 
120VAC outlet. Initial commissioning of the blinds, setup of 
Open/Close range limits, is conveniently programmed using 
the Somfy RF remote. Once the RTS motor has learned the 
range (open/close limits) it can then be placed in Learn mode 
and learned to blind controls from InFusion Design Center. 
 
Station/System Specifications 

Description 

Specification

Dimensions, HWD 

3.375” x 2.19” x 0.9”

Weight 2.1oz 
Power Supply 

120VAC 60Hz

Somfy™ RTS Motor Control 

RTS 

RadioLink Range RFE1000 to 
InterPoint RTS 

100 feet radius 

Radio Range InterPoint to RTS Motor 

30 feet radius

Station Equivalent 

1 RadioLink Station

Number of Addresses possible in each 
InterPoint RTS Station 

255 

Number of Addresses possible in each 
Somfy RTS Motor 

10 

LED Indicators 

Vantage Status LED symbol 

on front 

Ambient Operating Temperature 

0-40°C / 32-104°F

Ambient Operating Humidity 

5-95% non-condensing

FCC and IC Approved 

yes 

 
System Requirements 
This station is compatible with InFusion Design Center 
software, version 1.2 or higher. 
 
Installation 
Installation of Vantage products should be performed or 
supervised by a 

Certified Vantage Installer. 

InterPoint may be 

plugged into any properly located 120VAC outlet inside a 
weather proof environment. Proper operation is indicated by 
an LED indicator on the front of the device 
 
Station Set Up in Software 

InFusion: 

First select the room, then click on 

Vantage Objects 

in the 

Object Explorer

 and expand 

Stations, RadioLink

. From 

the list of stations double click on the 

InterPoint RTS Station

 to 

place it in the room. In the 

Object Editor,

 name the station and 

make sure it is on the correct RadioLink bus port. 
 
Configuration 
RadioLink stations need to be configured to associate which 
physical station goes with the station in software.  
 
When the station is initially powered-up, the Status LED will 
blink three times followed by a pause - this means the station 
is powered correctly but not yet on the network. 

Before

 

uploading the file to the Vantage system, do the following: 
From Design  
Center, click in the 

Serial Number

 section in the 

Object Editor

  

and type in the serial number. The serial number of each 
station is located on a permanent sticker on the back of the 
station. The Main Controller will add to its network and 
configure all the RadioLink stations that it has serial numbers 
for. This may take from a few seconds to several minutes 
depending on the number of RadioLink stations on the 
network. The Status LED stays on when the station has been 
added to the network and configured. 

NOTE: The status LED also blinks randomly when transmitting 
code to the RTS blind motor. 
 
Setup InterPoint RTS Station  
Commission the blinds first, following the steps in the Somfy 
RTS manual shipped with the blinds. Commissioning (setting 
open and close limits) of blinds will occur using Somfy’s RF 
remote. Once the blinds have been commissioned they need to 
be learned to the Vantage InFusion System. Please carefully 
follow the steps below to integrate InterPoint RTS to the 
Somfy RTS motors. 
 

The following instructions are for TEACHING purposes.

 The 

instruction is based on multiple RTS blinds in a single room. In 
this example we want control of each of four individual blinds, 
simply named Blind 1, Blind 2, Blind 3 and Blind 4. Next we 
want to control groups of blinds simultaneously in the same 
room. Finally we want to control all the blinds simultaneously 
in the same room. To accomplish this, please carefully follow 
the steps below. 

Learning

 the concepts in this example will 

“open the door” to multiple programming configurations of the 
InterPoint RTS station. Please also see graphical hierarchy 
example drawing (last page). 
 

CAUTION:

 If you need to start any of the following steps over, 

please see 

Un-Learn Steps

 below before proceeding. 

 
Individual Learn Steps, Blinds 1 – 4  

1.

 

Disconnect power to all blinds accept the one being 
learned. 

2.

 

Press and hold the program button on the back of the 
Somfy RF remote for about 3 seconds. 

3.

 

The powered blind will jog slightly both directions 
indicating that it is in 

Learn

 mode. 

4.

 

Connect Design Center software to the InFusion 
System Controller via IP or USB and make sure the 
InterPoint RTS station is selected in the 

Grid

 section. 

5.

 

 In the 

Object Editor

 add a blind by clicking on 

the 

Add Blind

 icon. 

6.

 

 Highlight the newly added blind in the 

Object 

Editor

 and then click on the 

Program Blind

 icon. 

7.

 

The powered blind will jog slightly both directions 
indicating that it received the command. 

8.

 

 Test the Blind action – UP, DOWN and 

STOP operations to verify it is correctly learned. 

9.

 

Repeat these steps for the remaining blinds. 

 
Group Learn Steps (continue from steps above) 

1.

 

All the blinds should be powered. 

2.

 

In this example: 

a.

 

Group 1 = Blind 1 and Blind 2. 

b.

 

Group 2 = Blind 3 and Blind 4. 

3.

 

 In the 

Object Editor

 add a blind by clicking on 

the 

Add Blind

 icon. Design Center will name this 

Blind 

5

 by default after having completed all the steps to 

this point. 

4.

 

In the 

Object Editor

 rename 

Blind 5

 to 

Group 1

5.

 

 Highlight 

Blind 1

 and click on the icon, 

Put Blind 

in learn Mode

6.

 

Blind 1

 will jog slightly both directions indicating that 

it received the command. 

7.

 

 Highlight 

Group 1

 and click on the icon, 

Program 

Blind