WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service

agency, or the gas supplier.

®

INFRARED VENT-FREE NATURAL GAS HEATER

This appliance may be installed in an aftermarket* manufactured (mobile)

home, where not prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

OWNER’S OPERATION AND INSTALLATION MANUAL

Содержание VN1800D

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas...

Страница 2: ...sea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than others These include pregnant women...

Страница 3: ...eater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Fresh Air for Combustion and Ventilation pages 5 through 8 7 K...

Страница 4: ...ent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteries or other sourc...

Страница 5: ...The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unus...

Страница 6: ...d gas heater ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 B...

Страница 7: ...s fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of th...

Страница 8: ...the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openings f...

Страница 9: ...ou can locate heater on floor away from a wall An optional floor mounting stand is needed Purchasethefloormountingstandfromyourdealer See Accessories page31 WARNING ICON G 001 WARNING Never install th...

Страница 10: ...een placed inside the heater for protection during shipping Locating Thermostat Sensing Bulb 1 Remove front panel of heater see Figure 7 page 11 2 Locate thermostat sensing bulb just under the burner...

Страница 11: ...w walls wall areas between studs or to solid walls concrete or masonry Decide which method better suits your needs Either method will provide a secure hold for the mounting bracket INSTALLING HEATER T...

Страница 12: ...ge is provided with heater Attaching to wall stud method For attaching mounting bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up...

Страница 13: ...e near bottom on back panel of heater see Figure 14 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screws into hollow or solid wall install wall a...

Страница 14: ...where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong he...

Страница 15: ...In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off open end of gas...

Страница 16: ...ff valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve...

Страница 17: ...AS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruc...

Страница 18: ...rol knob for 30 seconds This will allow air to bleed from the gas system If thermostat control knob does not pop up when released contact a qualified service person or gas supplier for repairs 6 Keep...

Страница 19: ...en the burners light a whoosh noise will be heard Figure 17 Pilot TO SELECT HEATING LEVEL WARNING ICON G 001 WARNING When running heater set control knob at the 1 2 3 or 4 locked positions Never set c...

Страница 20: ...d VN2550ITA Only Since the thermostat measures the temperature of air near the heater cabinet this may not always agree with room temperature depending on housing construction installation location ro...

Страница 21: ...build ing Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push...

Страница 22: ...d release ignitor button This will light pilot The pilot is attached to the front of burner If needed keep pressing ignitor button until pilot lights If pilot does not light turn control knob clockwis...

Страница 23: ...ERATING HEATER Models VN1800D and VN3000D Continued WARNING ICON G 001 WARNING When running heater set control knob at LOW MEDIUM or HIGH locked positions Never set control knob between locked positio...

Страница 24: ...performed Shutting Off Burner Only pilot stays lit 1 Turn control knob clockwise Clockwise to the PILOT position MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions pages...

Страница 25: ...hown in Figure 25 turn heater off see To Turn Off Gas to Appliance page 20 models VN1800ITA and VN2550ITA or page 24 models VN1800D and VN3000D see Troubleshooting pages 26 through 29 INSPECTING BURNE...

Страница 26: ...or button is pressed in there is no spark at ODS pilot POSSIBLE CAUSE 1 Ignitor electrode posi tioned wrong 2 Ignitor electrode broken 3 Ignitor electrode not connected to ignitor cable 4 Ignitor cabl...

Страница 27: ...lot see Cleaning and Mainte nance page 26 or replace ODS pilot assembly 6 Replace thermocouple 7 Replace control valve 8 Wait one minute for safety interlock system to reset Repeat ignition operation...

Страница 28: ...Maintenance page 26 or replace burner orifice s 2 Replace burner 3 Replace gas regulator 1 Replace burner 2 Contact local natural gas company 3 Turn control knob until it locks at desired setting 1 Pr...

Страница 29: ...n air OBSERVED PROBLEM Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Ventilate room Stop us...

Страница 30: ...iezo Piezo Pressure Regulator Setting 6 W C 6 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 Minimum 7 7 Dimensions Inches H x W x D Heater 23 5 x 18 5 x 8 23 5 x 25 9 x 8 Carton 25 8 x 21 3 x 1...

Страница 31: ...malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the defective part to the factory Parts Not Under Warranty Contact authorized dealers of this...

Страница 32: ...4 14 17 16 21 18 22 20 19 15 13 ILLUSTRATED PARTS BREAKDOWN Model VN1800ITA HEATER EXPLODED VIEW 23 19 23 18 ODS PILOT ASSEMBLY A B C 23 1 23 2 23 3 23 4 23 5 23 7 23 6 23 8 23 12 23 16 23 11 23 15 23...

Страница 33: ...nitor Cable 1 20 100614 01 SIT Tube 1 21 100610 01 Inlet Tube 1 22 099211 01 Hex Head Screw 2 23 See Detail Burner Assembly 1 23 1 099218 01 Burner 1 23 2 098508 01 Valve Retainer Nut 1 23 3 099056 03...

Страница 34: ...4 8 5 6 7 12 23 9 10 24 14 17 16 21 18 22 20 19 15 13 ILLUSTRATED PARTS BREAKDOWN Model VN2550ITA D C 23 1 23 2 23 3 23 8 23 16 23 17 23 11 B A 23 12 23 5 23 6 23 4 23 9 23 7 23 13 23 20 23 10 23 14 2...

Страница 35: ...01 SIT Tubing 1 21 100610 01 Inlet Tubing 1 22 099211 01 Hex Head Screw 2 23 See Detail Burner Assembly 1 23 1 099218 03 Burner 1 23 2 098508 01 Valve Retainer Nut 1 23 3 099056 06 Injector 4 23 4 100...

Страница 36: ...5 6 7 12 13 9 10 14 16 15 17 18 HEATER EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model VN1800D BURNER ASSEMBLY A B C 13 1 13 2 13 3 13 10 13 4 13 5 13 6 13 7 13 18 13 8 13 9 13 14 13 13 13 12 13 11 13...

Страница 37: ...8 01 Valve Retainer Nut 1 13 3 099056 03 Injector 3 13 4 099048 01 Tubing Valve to Plaque A 1 13 5 099049 01 Tubing Valve to Plaque B 1 13 6 099050 01 Tubing Valve to Plaque C 1 13 7 099057 01 Pressur...

Страница 38: ...IEW ILLUSTRATED PARTS BREAKDOWN Model VN3000D 13 17 13 16 ODS PILOT BURNER ASSEMBLY E D C 13 1 13 2 13 3 13 9 13 4 13 5 13 7 13 6 13 18 13 8 13 10 13 14 13 13 13 12 13 15 13 11 B A 1 2 3 11 6 13 4 8 5...

Страница 39: ...01 Valve Retainer Nut 1 13 3 099056 02 Injector 5 13 4 099052 01 Tubing Valve to Plaque B D 1 13 5 099053 01 Tubing Valve to Plaque C 1 13 6 099057 01 Pressure Tap Fitting 1 13 7 099054 01 Tubing Val...

Страница 40: ...uctions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse acci...