Vanguard VMH26PRA Скачать руководство пользователя страница 1

Save this manual for future reference.

OWNER’S OPERATION AND INSTALLATION MANUAL

VENT-FREE PROPANE/LP GAS

COMPACT CLASSIC HEARTH

®

 FIREPLACE

®

Shown with Optional

Cabinet Mantel/Hearth

Base Accessory

VMH26PRA

15,000 to 26,000 Btu/Hr

Remote Control Ready

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed

by a qualified installer, service agency, or the
gas supplier.

WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to 

Air for Combustion and

Ventilation section on page 5 of
this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is
not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Содержание VMH26PRA

Страница 1: ...nt Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury or...

Страница 2: ...lothing or other flammable material on or near the appliance Never place any objects on the heater Fireplace front and screen be comes very hot when running fireplace Keep children and adults away fro...

Страница 3: ...et could cause pilot outage 17 Do not operate fireplace if any log is broken Do not operate fireplace if a log is chipped dime sized or larger 18 To prevent performance problems do not use propane LP...

Страница 4: ...to the slots under the log Do not allow log to con tact flame If flame contacts log soot will be created 5 Reattach screen by placing the notches in the screen frame over the shoulder screws and pushi...

Страница 5: ...on and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings expose...

Страница 6: ...__ Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space...

Страница 7: ...tilated Crawl Space To Crawl Space To Attic AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When...

Страница 8: ...ting fireplace where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent freefireplacesaddmois ture to the a...

Страница 9: ...l plywood etc may be butted up next to the sides and top edge of the firebox Combus tible materials should never overlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile...

Страница 10: ...ss trim kit and mantel Be careful not to damage wall or mantel 9 Place wood base next to wall at instal lation location 10 Attach wood base to floor with two 1 3 4 black screws provided see Figure 13...

Страница 11: ...ed to the terminals on the blower bracket assembly Figure 16 Installing Blower Bracket Assembly Valve Cover Shield Snap Bushing Upper Louver Assembly Branch Support CAUTION Label all wires prior to di...

Страница 12: ...ldbe routed through the bushing in the hole on the outer casing of heater Blower Bracket Assembly Screw Wire Harness Power Cord Plastic Wire Strap Wire Harness Switch Switch Clamp Connector not includ...

Страница 13: ...d or is installed wrong fireplace may not run properly Propane LP Supply Tank Vent Pointing Down External Regulator Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or ma...

Страница 14: ...to allow accessibility from the fireplace The flexible gas supply line con nection to the equipment shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connec...

Страница 15: ...eruseanopen flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once TestPressuresEqualToorLessThan 1 2 PSIG 3 5 kPa 1 Clo...

Страница 16: ...a quali fied installer familiar with low voltage wiring procedures Figure 30 Installing Remote Receiver Wire harness provided in the fireplace hardware pack Installing 9 Volt Battery in Hand Held Rem...

Страница 17: ...t one terminal of 25 ft wire to bottom contact of switch see Figure33 2 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the positions on yo...

Страница 18: ...ith the fireplace screen in place Make sure fire place screen is installed before running fireplace 1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Set...

Страница 19: ...tructions on page 16 of this manual NOTICE You must light the pilot before using the hand held re mote control unit See Lighting Instructions on page 18 1 After lighting let pilot flame burn for about...

Страница 20: ...ctions on page 17 of this manual OPERATING BLOWER Auto Off On Switch This blower has three settings ON OFF andAUTO IntheONposition theblower will operate constantly In the OFF posi tion the blower wil...

Страница 21: ...cluding the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 45 3 Blow air through the ports...

Страница 22: ...aged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set...

Страница 23: ...requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe min...

Страница 24: ...SERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in O...

Страница 25: ...Pressure in of water Maximum 14 Minimum 11 Dimensions Inches H x W x D Fireplace including hood and screws 25 7 8 x 26 13 16 x 9 3 8 Carton 32 5 8 x 27 3 16 x 11 5 8 Weight pounds Fireplace 44 1 2 lbs...

Страница 26: ...ACE VMH26PRA For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN VMH26PRA 39 37 38 22 40 28 30 12 7 35 25 10 4 9 7 23 1 2 8 4 4 14 6 24 27 33 34 31 31 13 17 5 21 11 26 18 20 15 32...

Страница 27: ...1006 02 Pilot Bracket 1 21 098249 01 Nut M5 2 22 103781 02 Gas Valve 1 23 102639 01 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control Shield 1 26 103295 03CJ Screen Assembly 1 27 107153...

Страница 28: ...Included with all mantels CABINET MANTEL WITH BUILT IN HEARTH BASE AND ROUNDED LEG STYLING Unfinished GM921U Walnut Finished GM920F Cherry Finished GM924F Appearance May Differ by Model For use with f...

Страница 29: ...heater to be turned on and off by using a hand held remote control WALL MOUNTED THERMOSTAT KIT GWMT1 Not Shown Forallmodels Allowseasywallaccesstothe operation of your gas log heater This will allow...

Страница 30: ...cts caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO T...

Отзывы: