Vanguard VMH26NRA Скачать руководство пользователя страница 1

Save this manual for future reference.

OWNER’S OPERATION AND INSTALLATION MANUAL

VENT-FREE NATURAL GAS

COMPACT CLASSIC HEARTH

®

 FIREPLACE

®

Shown with Optional

Cabinet Mantel/Hearth

Base Accessory

15,000 to 26,000 Btu/Hr

Remote Control Ready

VMH26NRA

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to 

Air for Combustion and

Ventilation section on page 5
of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Содержание VMH26NRA

Страница 1: ...tment Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause inj...

Страница 2: ...urns or clothing ignition Fireplace will remain hot for a time after shutdown Allow sur faces to cool before touching Carefully supervise young chil dren when they are in same room with fireplace When...

Страница 3: ...ATURES AU TO ON OF F CO OL ER WA RM ER TE MP ON OFF REMOTE Figure 2 Removing Fireplace Hood IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE...

Страница 4: ...og locator tabs fit into the slots under the log Do not allow log to contact flame If flame contacts log soot will be created 5 Reattach screen by placing the notches in the screen frame over the shou...

Страница 5: ...tion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings expo...

Страница 6: ...um Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ____________ Btu Hr Gas water heater ____________ Btu Hr Gas furnace ____________ Btu H...

Страница 7: ...ated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 5 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From I...

Страница 8: ...reyouboughtfireplaceforproper type fireplace INSTALLATION ITEMS Before installing fireplace make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equip...

Страница 9: ...aterials should never overlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any neces sary openings like louver...

Страница 10: ...to damage wall or mantel 9 Place wood base next to wall at instal lation location 10 Attach wood base to floor with two 1 3 4 black screws provided see Figure 13 Ifthefloorisconcreteuseanchormethod s...

Страница 11: ...hen ser vicing controls Wiring errors can cause improper and dan gerous operation CAUTION Verify proper op eration after servicing 3 Note the wire locations on back of AUTO OFF ON switch The terminals...

Страница 12: ...Wiring Diagram For Blower Accessory Built In Installation 4 Plug power cord to the outlet receptacle not provided as shown in Figure 20 Wind the extra cable in power cord and and tie it up with the pl...

Страница 13: ...too small un due loss of pressure will occur CAUTION Usepipejointseal ant that is resistant to liquid pe troleum LP gas Attaching Wood Base to Solid Floor For attaching base to solid floors concrete...

Страница 14: ...TICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure23 The flexible gas supply line con nection to the eq...

Страница 15: ...pliance with its appliance maingasvalve controlvalve andequip ment shutoff valve from gas supply pip ingsystem Pressuresinexcessof1 2psig will damage heater regulator 2 Cap off open end of gas pipe wh...

Страница 16: ...uali fied installer familiar with low voltage wiring procedures INSTALLATION Continued OPTIONAL WIRELESS HAND HELD REMOTE CONTROL ACCESSORIES GHRC Series GHRCTA Series Installing Receiver 1 Remove scr...

Страница 17: ...ary 1 Connect one terminal of 25 ft wire to bottom contact of switch see Figure32 2 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the pos...

Страница 18: ...to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation column 1 If you don t smell gas go...

Страница 19: ...utomatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output of the central heating system etc For...

Страница 20: ...llation instructions on page 17 of this manual OPERATING BLOWER Auto Off On Switch This blower has three settings ON OFF andAUTO IntheONposition theblower will operate constantly In the OFF posi tion...

Страница 21: ...ugh the ports slots and holes in the burner CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabi...

Страница 22: ...damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log...

Страница 23: ...n requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minim...

Страница 24: ...es a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during...

Страница 25: ...UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5190 for referral informa...

Страница 26: ...ACE VMH26NRA For more information visit www desatech com 39 37 38 4 22 40 32 11 28 30 12 7 35 25 10 9 7 23 1 2 20 20 8 14 6 24 33 19 34 31 31 13 41 21 5 26 18 15 27 20 3 20 29 16 18 3 17 42 36 4 4 20...

Страница 27: ...02445 01 Piezo 1 17 099918 02 Regulator Pilot 1 18 098271 07 Ignitor Cable 1 19 107186 02 Injector 1 20 M11084 26 Screw Hex Head 10 x 3 8 25 21 098249 01 Nut M5 6 22 103781 01 Gas Valve 1 23 102639 01...

Страница 28: ...ailable in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE AND T...

Страница 29: ...TO ON OFF COOLE R WAR MER TE MP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES For all models Allows the gas log heater to be operated in a manually or thermostati cally controlled...

Страница 30: ...aused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE FU...

Отзывы: