17
Engineer programming via the browser
Configuring Communications
288
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
You can view a list of all event exceptions for an event profile under Event
Exceptions on the Event Profiles screen.
NOTICE
You cannot delete the Default Event Profile, the Default Portal Event Profile or an
event profile that is assigned to an ATS. If you try to delete an event profile that is
in use, you will get an error.
Event Exception Definition
Event exceptions allow you to change the following settings for a range of
addresses within an event:
Report Event
SIA Code
CID Code
Event Address (e.g. Zone IDs, Area IDs, User IDs)
For example, in the Filter Group Intruder Alarms you could define an event
exception for a range of Zone IDs in the Burglary Alarm (BA) event as follows:
Do not report BA events for Zone ID 1 - 9
Remap the SIA Code from BA to YZ
Remap the CID from 130 / 1 to 230 / 1
Remap the Zone ID 1 - 9 to Zone ID 101 - 109
1. To configure an Event Exception Definition, complete the fields described in the
table below.
2. Click Save.
17.10.2.5.1
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...