Engineer programming via the browser
17
Configuration
237
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Idle Language determines the language which is displayed on the keypads
when the panel is in its idle state. If ‘Last Used’ is selected, the language
displayed is the language that is associated with the last user login.
The language used in the keypads and browser depends on the language
selection made for each user. For example, if the system language is set to
French, but the individual user’s language is set to English, English is the
language used in both keypads and browser for that user, regardless of the
specified system language.
See also
17.9.5
Configuring zones, doors and areas
17.9.5.1
Editing a zone
Engineer and User actions include Log, Isolate/Deisolate and Soak/Desoak for
each zone as allowable by the Security Grade EN 50131 Grade 2 and EN 50131
Grade 3.
1. Select Configuration > Inputs > All Zones.
The following window will be displayed.
You can select Configuration > Inputs > X-Bus Zones to configure wired zones
only or Configuration > Inputs > Wireless Zones to configure wireless zones only.
2. Configure the fields as described in the table below.
Zone
The number is presented for reference and can not be programmed.
Description
Enter a text (max. 16 characters) that serves to uniquely identify the zone.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...