background image

 

 

 

 

 

 

POE-8M

 

 

 

Quick Guide

 

 

 

User’s Manual

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание POE-8M

Страница 1: ...1 POE 8M Quick Guide User s Manual ...

Страница 2: ...f diagnostic test It takes about 10 seconds to complete the process Step4 Set your PC IP address to 192 168 2 100 same subnet 192 168 2 x as the web management Step5 Enter 192 168 2 1 default IP address of Web management from PC web browser The web management will display the following login page Enter admin for user ID system for password and click the OK button to login to the Web management Not...

Страница 3: ...o power on the connected PoE AP device for Port 1 You may also click PoE Scheduling to select time schedule for Power on off scheduling control Step8 Refer to Chapter 4 for further networking configurations Note Problems in setting up the web smart PoE switch Please refer to the last chapter for troubleshooting ...

Страница 4: ...lation 12 3 5 Cabling Requirements 12 3 6 Power Connection 13 3 7 Installation Steps 13 3 8 Reset to Default 15 4 Web Management 16 4 1 Setup your computer for Web management 16 4 2 Web management 19 4 3 Administrator 20 4 3 1 Authentication Configuration 20 4 3 2 System IP Configuration 21 4 3 3 System Status 21 4 3 4 Load Default Setting 22 4 3 5 Firmware Update 22 4 4 PoE 24 4 4 1 PoE Setting 2...

Страница 5: ... 40 4 8 QoS Setting 41 4 8 1 Priority Mode 41 4 8 2 Class of Service Configuration 42 4 9 Security 44 4 9 1 MAC Address Binding 44 4 9 2 MAC Address Scan 45 4 9 3 TCP UDP Filter 45 4 9 4 Web Management Filter 46 4 10 Spanning Tree 47 4 10 1 STP Bridge Settings 47 4 10 2 STP Port Settings 47 4 10 3 Loopback Detection Settings 48 4 11 Trunk Setting 49 4 12 DHCP Relay Agent 50 4 13 NTP Setting 50 4 1...

Страница 6: ...6 4 16 Logout 52 Appendix A Product Specifications 53 Appendix B Troubleshooting 55 B 1 Can NOT Access Web Page 55 B 2 Forget IP Address User ID and Password 55 ...

Страница 7: ... the Ethernet ports are all turned off initially and can be turned on per port basis through the web management to power on the corresponding remote PoE device The powered PoE device can be any equipment of Passive 24V DC PoE device such as WiFi AP IP camera IP Phone etc Each port can deliver up to 15 Watt Max to the corresponding remote PoE device Request of more power from remote PoE device may ...

Страница 8: ...ts PWR for system power Built in push button for default reset AC power on off switch OVP OCP OTP protections 2 1 Power on Switch The PoE Switch is equipped with an internal power supply to operate with 100 240 VAC 50 60 Hz The AC power cord connector is at the rear panel next to the power on off switch Turning on the power switch it will first perform self diagnostic test and take about 10 second...

Страница 9: ... web management switch After unpacking and taking out the entire package contents please check whether you have got the following items PoE Switch Unit One AC Power Cord One CD ROM for Quick Guide User s Manual If any of these above items is missing or damaged please contact your local dealer for replacement 3 2 Hardware Overview Front Panel The 8 ports of RJ 45 connector are on the front panel of...

Страница 10: ...network All the 8 ports support network speeds of either 10Mbps or 100Mbps and can operate in half and full duplex transfer modes These ports also support the automatic MDI MDIX crossover detection function to provide plug and play capability Reset Button The Reset button is used to reset all the setting back to the factory default values Make sure that all the settings of the switch are taken dow...

Страница 11: ...urces As a reference the strength of the electromagnetic field on site should not exceed the RFC standards for IEC 801 3 Level 2 3V M field strength The air temperature in the location should be within a range of 0 to 60 C The relative humidity in the location should not exceed 90 non condensing humidity The distance between the RJ 45 port and the standard network interface should not exceed 100 m...

Страница 12: ... 45 station ports require standard Cat 5 twisted pair UTP STP cable for connection When configuring within the 10 100 BASE T cabling architecture the cable distance should be within 100m The cable requirement for 10 100BASE TX connection is listed in table as follows 10BASE T 100 ohm Category 3 4 5 UTP STP cable 100BASE TX 100 ohm Category 5 UTP STP cable Auto MDI MDI X function The PoE Switch is ...

Страница 13: ...ed in the power you can then turn on the Power Switch to activate the switch 3 7 Installation Steps This section describes the step by step procedures for PoE setup Step1 Connect the PoE AP device to LAN port 1 and your PC to LAN port 8 of the PoE Switch as the above connection Step2 Set your PC IP address to 192 168 2 100 This PC IP address must be in the same subnet 192 168 2 x as the web manage...

Страница 14: ...ord Step5 Go to PoE and then select PoE Setting Step6 Click on Port No 1 and Update to power on the connected PoE AP device for Port 1 Step7 Install the rack mount kit on the 19 rack if needed Step8 Refer to Chapter 4 for further networking configurations ...

Страница 15: ...n the web smart switch Step2 Press and hold the reset button continuously for 10 seconds and release the reset button Step3 The switch will reboot for 5 seconds and the configuration of switch will reset back to the default setting Step4 Set your PC IP address to 192 168 2 100 Step5 Enter 192 168 2 1 from PC web browser to connect to web management Step6 Enter admin for username and system for pas...

Страница 16: ...net and subnet mask as the switch in order to configure the switch through PC web browser To find out the IP address information for your computer please run Command Line window in WinNT 2000 XP and enter ipconfig or enter winipcfg in Win9x For example if one IP address is 192 168 2 1 and the other IP address must be 192 168 2 x x can be any number between 2 and 254 for same Class C subnet For the...

Страница 17: ... connection status icon on the task bar This should bring up a window showing the status of the current network connection If there is no network status icon on the task bar please go to the Start Settings Network Local Area Connection of the Window task bar s Start menu Step 2 Click on the property icon Step 3 Double click on the Internet Protocol TCP IP icon ...

Страница 18: ...ring the IP Note1 An alternative configuration is to change the switch IP address into the same subnet as the computer This can be done in the Section 4 3 Admistrator for setting new switch IP address Note2 The PoE Switch has DHCP client ability This allows DHCP server or router to assign IP automatically However we do not recommend turning on the DHCP client because the DHCP server assign the IP ...

Страница 19: ...K button to login to the web management page as follows Menu Bar The Menu bar is on the left side of the screen where you may click to configure management functions Most configurations for administration services are under the Administrator menu Port Connection Status The on off status on the top of the screen gives the quick overview of the port connection status When a port is plugged in the sw...

Страница 20: ... the following Authentication Configuration System IP Configuration System Status Load Default Setting Firmware Update Reboot Device 4 3 1 Authentication Configuration This page shows the information for authentication configuration User can set new Username and Password in this page ...

Страница 21: ...lt is 255 255 255 0 Gateway Assign the network gateway for the web smart switch If you change the IP address of this switch and then press Update It will show update successfully then press Reboot button It will enter user login screen automatically 4 3 3 System Status This page shows the status of switch including MAC address and software version The comment field allows the network administrator...

Страница 22: ... user ID password and IP configurations It only restore all default settings related to switch behavior 4 3 5 Firmware Update User need to enter the password twice and press Update button to update the firmware The smart switch will erase the flash memory There is a self protection mechanism in the boot loader so the boot loader will keep intact The boot loader will restore the code to firmware up...

Страница 23: ...23 After pressing Update button the old web code will be erased Then you can select the new image file and press Update button to update the firmware you need ...

Страница 24: ... Click Confirm button to reboot the device Note The reboot is for software base instead of hardware base 4 4 PoE This PoE section describes the PoE functions and display the power on off status of each port 4 4 1 PoE Setting ...

Страница 25: ...25 4 4 2 PoE Power Delay This PoE power on off will be delayed in accord with the delay mode ...

Страница 26: ...26 4 4 3 PoE Scheduling The PoE on off control will be scheduling in accord with the schedule mode ...

Страница 27: ... items manually Speed When the Auto Negotiation column is set as Disable users have to set the connection speed to the ports ticked Duplex When the Auto Negotiation column is set as Disable users have to set the connection mode in Half Full to the ports ticked Pause Flow Control for connection at speed of 10 100Mbps in Full duplex mode Backpressure Flow Control for connection at speed of 10 100Mbp...

Страница 28: ...nction is accomplished by setting the following items Destination port The port mirroring function will lower the network throughput and it s recommended to set only one destination port in a network Monitored packets 1 Disable means this function is disabled 2 RX means copy the incoming packets of the selected source port to the selected destination port 3 TX means copy the outgoing packets of th...

Отзывы: