WARNING 

INSTRUCTIONS FOR SELF-REGULATING HEATING CABLE  

(W01-1572, W01-1573, W01-1574) 

 

Do not use damaged heating cables, power cord or plug.  Remove and

 

replace immediately to prevent a fire, shock or arcing hazard. 

 

These heating cables provide plumbing systems protection from damage due to freezing.  It can be used 

in residential and commercial applications.  The cables can automatically adjust heat output according 

to  the ambient temperature conditions.  Under cooler conditions, the heat output increases, and as the 

temperature rises, the output decreases to save on energy.  The cables operate on 120V and are 

available in various pre-assembled lengths. 

 

Features 

 

- Pre-assembled cable includes a 6 foot power cord and plug 

- Suitable for plastic or metal pipes 

- Easy installation, as the cable can be overlapped without the risk of becoming overheated or burnt. 

 

General Safety Information 

 

Read and understand all instructions in this manual and the following installation instructions and safety 

warnings.  Electrical cables, if not installed correctly or are damaged, can present a fire, shock and arcing 

hazard.  

 

1.

 

Installation must be in compliance with National Electrical Codes (NEC). 

2.

 

Use 30-mA ground fault protection on each heating cable branch circuit for maximum protection. 

3.

 

Use only fire-resistant insulation, such as fiberglass or preformed foam.  Do not embed heating 
cable in the insulation. 

4.

 

Use 1/2" to 1" fiberglass tape or plastic cable ties when attaching cable to pipe.  Do not use wire or 
metal clamps. 

5.

 

Before installing or servicing, ensure that all power to circuits is OFF. 

6.

 

Do not twist cable during installation. 

7.

 

Do not expose cable to temperatures above 185° F, as this will damage the cable. 

8.

 

Do not use extension cords. 

9.

 

Save all instructions for future reference. 

 

Specifications 

 

Part No. 

Reference 

Voltage 

Length 

Power Output on 

Pipe @ 40

°F (5

°

C)

 

Power Output on 

Pipe @ 50

°F (10

°

C)

 

Power Output on 

Pipe @ 32

°F (0

°

C)

 

Max. Exposure 

Temperature 

W01-1572 

110-120VAC 

15' 

90 

75 

150 

185°F (85°C) 

W01-1573 

110-120VAC 

25' 

150 

125 

250 

185°F (85°C) 

W01-1574 

110-120VAC 

50' 

300 

250 

500 

185°F (85°C) 

 

 