![Valor Legend G3.5 Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/valor/legend-g3-5-series/legend-g3-5-series_installation-instructions-manual_3333030001.webp)
Legend G3.5
Model
700JN
700JP
Gas
Natural Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
26,000
26,000
Input Minimum (Btu/h)
10,000
10,000
Manifold Pressure (in w.c.)
3.5
10.0
Minimum Supply Pressure
(in w.c.)
5.0
11.0
Maximum Supply Pressure
(in w.c.)
10.0
14.0
Main Burner Injector Marking
750
260
Pilot Injector Marking
51
30
Min. Rate By-Pass Screw
150
105
Natural Gas Burner:
Has two interlaced rows of slots
Propane Gas Burner: marked “LPG”
Has single row of slots and two rows
of small holes
Burner identifi cation
4006429-02
©2017, Miles Industries Ltd.
Gas Conversion Kit
700JNGK & 700JPGK
Installation Instructions
This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
1 By-pass screw
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Nut driver 8 mm or 5/16”, to remove burner nuts
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
• Manometer, to set pressure
Specifi cations
Use with with
Valor Models 700J Heaters ONLY
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.