9” (229 mm)
A
B
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance
Combustible Mantel Clearances
*Measure taken from the underside of the mantel to finished hearth
or surface that the unit is sitting on.
Finishing Materials
Combustible materials:
Material such as wood,
compressed paper, plant fibers, plastics or any material
capable of igniting and burning, whether flame-proofed or
not, plastered or un-plastered.
Non-combustible materials:
Material such as steel, iron
brick, tile, concrete or materials that bear the UL mark for
zero (0) fire rating.
Sidewall Clearances
Minimum
distance from side of appliance (liner box) to
combustible wall: 9” (229 mm).
Mantel
Projection A
1”
(25 mm)
4”
(101 mm)
8”
(203 mm)
14”
(355 mm)
Mantel
Height B*
28”
(711 mm)
32”
(813 mm)
35”
(889 mm)
38”
(965 mm)
sidewall
WARNING
Some materials or items, altough safe, may discolor, warp, crack, peel, and
so on because of the heat produced by the fireplace. Avoid placing candles,
paintings, photos, and other items sensitive to heat around the fireplace.
8