Safety and Warning Information

Children and adults should be 

ALERTED

 to the hazards 

of high surface temperature and should 

STAY AWAY

 to 

avoid burns or clothing ignition.

YOUNG CHILDREN

 should be 

CAREFULLY

 

SUPERVISED

 when they are in the same room as 

the appliance. Toddlers, young children and others 

may be susceptible to 

ACCIDENTAL CONTACT 

BURNS

. A physical barrier is recommended if there 

are at risk individuals in the house. To restrict access 

to a fireplace or stove, 

INSTALL AN ADjUSTABLE 

SAFETY GATE

 to keep toddlers, young children and 

other at risk individuals out of the room and away from 

hot surfaces.

DO NOT 

place furniture or any other combustible 

household objects within 36” of the fireplace front.

READ

 and 

UNDERSTAND

 all instructions carefully 

before starting the installation. 

FAILURE TO FOLLOW

 

these installation instructions may result in possible fire 

hazard and will void the warranty.
Prior to the first firing of the fireplace, 

READ

 the 

Owner’s Information section of this manual.

DO NOT USE 

this appliance if any part has been under 

water. Immediately, 

CALL

 a qualified service technician 

to inspect the unit and to replace any part of the control 

system and any gas control that has been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED

 by a 

qualified service person. The appliance and venting 

system should be 

INSPECTED

 before initial use and at 

least annually by a professional service person. More 

frequent cleaning may be required due to excessive 

lint from carpeting, bedding, etc. It is 

IMPERATIVE

 that 

the unit’s control compartment, burner, and circulating 

air passageways 

BE KEPT CLEAN 

to provide for 

adequate combustion and ventilation air.
Always 

KEEP

 the appliance clear and free from 

combustible materials, gasoline, and other flammable 

vapors and liquids.

NEVER OBSTRUCT 

the flow of combustion and 

ventilation air. Keep the front of the appliance 

CLEAR

 

of all obstacles and materials for servicing and proper 

operation.
Due to the high temperature, the appliance should be 

LOCATED

 out of traffic areas and away from furniture 

and draperies. Clothing or flammable material 

SHOULD 

NOT BE PLACED 

on or near the appliance.

This unit MUST be used with a vent system as 

described in this installation manual. 

NO

 

OTHER

 vent 

system or components 

MAY BE USED

.

This gas fireplace and vent assembly 

MUST

 be vented 

directly to the outside and 

MUST

 

NEVER

 be attached 

to a chimney serving a separate solid fuel burning 

appliance. Each gas appliance 

MUST USE 

a separate 

vent system. Common vent systems are 

PROHIBITED

.

INSPECT

 the external vent cap on a regular basis to 

make sure that no debris, plants, trees, shrubs are 

interfering with the air flow.
The glass door assembly 

MUST

 be in place and sealed 

before the unit can be placed into safe operation.

DO NOT OPERATE

 this appliance with the glass door 

removed, cracked, or broken. Replacement of the glass 

door should be performed by a licensed or qualified 

service person. 

DO NOT

 strike or slam the glass door.

The glass door assembly 

SHALL ONLY 

be replaced 

as a complete unit, as supplied by the fireplace 

manufacturer. 

NO SUBSTITUTE

 material may be used.

DO NOT USE 

abrasive cleaners on the glass door 

assembly. 

DO NOT ATTEMPT

 to clean the glass door 

when it is hot.

TURN OFF

 the gas before servicing this appliance. 

It is recommended that a qualified service technician 

perform an appliance check-up at the beginning of each 

heating season.
Any safety screen or guard removed for servicing 

MUST BE REPLACED 

before operating this appliance.

BE CAREFUL

 not to put any decorating objects 

sensitive to heat to close above or around the fireplace 

as it gets very hot when operating.

DO NOT 

use this heater as a temporary source of heat 

during construction.
This appliance is a 

DOMESTIC ROOM-HEATING AP-

PLIANCE

. It must not be used for any other purposes 

such as drying clothes, etc.

State of California. Proposition 65 Warning. 

Fuels 

used in gas, wood-burning or oil fired appliances, 

and the products of combustion of such fuels, contain 

chemicals known to the State of California to cause 

cancer, birth defects and other reproductive harm. 

California Health & Safety Code Sec. 25249.6.

4

Содержание Legend 739ILN

Страница 1: ...ble for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Do not store or use gasoline or other flammable vapors and li...

Страница 2: ...l your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time o...

Страница 3: ...tion 14 Ceramic Bricks Installation 15 Ceramic Logs Installation 15 Window Refitting 17 Remote Control Initial Set up 17 Operation Check Aeration Settings Adjustment 18 Remote Control Handset Wall Hol...

Страница 4: ...ration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the applian...

Страница 5: ...h the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For installations a...

Страница 6: ...nstall into combustible construction This appliance is NOT APPROVED for installation with a zero clearance kit 739IL fireplace Chimney Terminal Cap Flashing 2 x 3 approved flex chimney liners running...

Страница 7: ...tion Electrical inlet Optional Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see...

Страница 8: ...red or un plastered Non combustible materials Material such as steel iron brick tile concrete or materials that bear the UL mark for zero 0 fire rating Sidewall Clearances Minimum distance from side o...

Страница 9: ...for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal...

Страница 10: ...ce cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are bolted or screwed on such as dampers or baff...

Страница 11: ...ill an access hole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been install...

Страница 12: ...place to avoid damage electrical outlet fan cavity Fan installation If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the bac...

Страница 13: ...the back of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 t...

Страница 14: ...ting of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing...

Страница 15: ...pack the ceramic logs very carefully to avoid damaging the fragile material Install the logs as shown below Please note that the position of the Logs is critical to insure proper performance of the ap...

Страница 16: ...end on the pin located on the rear log Rest its wider end on the the crook in the front left log at an angle of approximately 30 degrees from the center line of the fireplace to allow for the flame t...

Страница 17: ...in the window seal Remote Control Initial Set up The receiver and the handset of the remote control sys tem must be initially synchronized before the first use 1 Insert alkaline batteries in the remot...

Страница 18: ...ect the temperature sensor located in the remote handset Operation Check Aeration Settings Adjustment Operation Check Turn the fireplace flame up and down using the remote control to confirm that the...

Страница 19: ...ion of the surface has the immediate effect of compromising the strength of the glass An emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry p...

Страница 20: ...e appliance uses four 1 5 V AA alkaline batteries for its remote control receiver and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending on usage Removing the...

Страница 21: ...batteries you can turn off the appliance with the manual switch located on the right hand side of the valve If the 1265WSK Wall switch is installed and the remote control will not be used remove the b...

Страница 22: ...rns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and large...

Страница 23: ...sing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in the...

Страница 24: ...you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go to be...

Страница 25: ...kaline batteries NOTE With very low battery the valve shuts off the fire completely This does not happen when the power supply is interrupted CAUTION DO NOT USE a screwdriver or other metallic object...

Страница 26: ...the oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION g 1 Locate the pilot g 3 inside of rebox at Left H...

Страница 27: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram 27...

Страница 28: ...r 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner approved to CAN...

Страница 29: ...or air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cove...

Страница 30: ...t Mount 4000138 28 Pilot Gasket B 4000140 29 Burner Tray 4001676 30 Pipe Valve to Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gaske...

Страница 31: ...NG LPG 18 20 25 21 22 23 24 19 49a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 44 43 45 62 63 64 65 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 14a NG...

Страница 32: ......

Страница 33: ...39IL NG natural gas LPG propane Serial No Front Trim code description e g 743FVI Double Door FenderFire Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email...

Страница 34: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: