Valor L1 1600KN Скачать руководство пользователя страница 1

©2021, Miles Industries Ltd.

4008055-07

Hot glass 

will cause burns.
Do not touch glass 

until cooled.
Never allow children 

to touch glass.

A barrier designed to reduce 

the risk of burns from the hot 

viewing glass is provided with this 

appliance and must be installed for 

the protection of children and 

other at-risk individuals.

DANGER

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings 

exactly could result in serious 

injury, death, or property damage.

Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do 

not use any phone in your building.

Leave the building immediately.

Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions.

If you cannot reach your gas supplier, 

call the 

fi

 re department.

Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Direct Vent Zero Clearance

Gas Fireplace

natural gas    1600KN

propane gas   1600KP

Installation Manual

L1

SEE-THRU

Installer: Leave this manual with the appliance.

Consumer: Retain this manual for future reference.

Installer: Place model/serial number here.

Содержание L1 1600KN

Страница 1: ...in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the buildin...

Страница 2: ...s reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appli...

Страница 3: ...of Co linear Conversion Accessories 25 Installation 26 Appliance Preparation 26 Unpack Appliance 26 Fit Standoffs 26 Convert from Top to Rear Outlet if required 26 Fit Appliance into Framing 27 Remov...

Страница 4: ...perature of projection surfaces will be reduced when barrier screens are installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by...

Страница 5: ...to a chimney serving a separate solid fuel burning ap pliance Each gas appliance must use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass...

Страница 6: ...ted on the left hand side of the firebox A shut o valve not supplied is required on the supply line to isolate the unit during service See Gas Supply Installation section for details Conversion Kits T...

Страница 7: ...Barrier Screen 1530CIK Clean Install Kit Fine Mesh REQUIRES HeatShift 4007929 1550LSBv2 Linear 3 1 2 Surround Black 4004215 1575LFB Linear 1 Finishing Trim Black 4005564 Gas Conversion Kits 1500KNGK C...

Страница 8: ...from side to top outlet Center of vent Heat shield required for side vent outlet applications Valve access side 18 1 2 470 mm 2 7 8 73 mm 9 1 4 235 mm 18 1 2 470 mm 2 3 4 70 mm 5 1 2 140 mm 33 1 8 841...

Страница 9: ...Con tent sheet Also check that you have Fuel bed packed separately Liner panels packed separately Remote Battery and Wall Switch Kit HeatShift System components if used Gas conversion kit if necessar...

Страница 10: ...protected environments as defined in the GV60CKO Outdoor Conversion Kit instruction manual Surrou d nd l Plate i with h Barr rier Screen required Narro ow 1 Trim 1575LFB and wider 3 1 2 steel Trim 155...

Страница 11: ...36 Min to Ceiling 44 42 40 38 33 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Same dimensions and restrictions apply to both sides of the appliance Combustible Mantel Left Side View...

Страница 12: ...12 39 11 16 Fireplace Opening Wall Min 4 to wall or combustible mantel leg Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Installation Planning Mantel Clearances...

Страница 13: ...ard required above on each side and below engine opening NOT supplied see page 36 NOTE Height of cavity may be affected by vent configuration with clearance see page 26 NOTE This unit requires a solid...

Страница 14: ...ting are based on us ing Dura Vent elbows Elbow curve radius dimensions will vary when using other brands and in general are slightly bigger Minimum 12 inches vertical pipe section required right at u...

Страница 15: ...ard to be used as a wall surface immediately surrounding the unit s opening see diagram for minimum coverage Extending the cement board well beyond the minimum shown will help avoid cracking due to di...

Страница 16: ...ave it finished clean with no tile etc Be aware that a trim is always required on the front and rear of the unit Finish should not cover the trims 1575 and 1550 Trims Only the 1575 and 1550 style trim...

Страница 17: ...ture Installation Planning Wall Finish Always pre drill screw holes through cement board and use screws with self milling head Always use mesh tape over joints Always stagger joints in wall board Behi...

Страница 18: ...wall assembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Combusti...

Страница 19: ...ERMINATION 2 PIECE WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION PIPE LENGTH...

Страница 20: ...degrees take o elbow shipped with the appliance 6 Each 90 degrees elbow installed on the horizon tal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from allowable...

Страница 21: ...venting with no vertical rise The level of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restrict...

Страница 22: ...regulator assembly located within 15 feet 4 6bm below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combus...

Страница 23: ...Vertical wall Min 24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Vertical Vent Termination Roof Pitch Minimum H feet Flat to 7 12 1 Over 7 12 to 8 12 1 5 O...

Страница 24: ...tion of vent system may only be installed within a solid fuel burning fireplace and chimney Installation Into Existing Adjacent Chimney The appliance can be adapted to co linear applications using an...

Страница 25: ...DVA CLAA Examples of Co linear Terminal Configurations Examples of Co axial to Co linear Appliance Adapters 10 10 3 Inlet Exhaust Collars 7 5 8 dia collar Flashing Kit Co Linear Terminal typical Co ax...

Страница 26: ...d them as shown and fix the loose end to the top of the firebox 2 The four side stand o s are supplied flat Bend them and fix them to the sides of the firebox as indicated with the screws supplied 2 s...

Страница 27: ...Make sure that the unit is at the right height with consideration to the height of the hearth or combustible flooring 3 Fold out the 6 mounting tabs 3 front 3 rear and recess the appliance in the fra...

Страница 28: ...e the window locate the levers on each side of the window towards the top Using your fin ger pull the lever towards you and unhook it from the window frame bracket 2 Gently pull the top of the window...

Страница 29: ...by 3 screws located right behind the upper edge of the fireplace opening Recycle this panel as it is no longer needed Repeat this procedure on the reverse side of the appliance Install HeatShift Take...

Страница 30: ...ug to plug into a grounded recepta cle installed within the fireplace enclosure by a qualified electrician The receptacle housing and strain relief are supplied and installed as part of the fireplace...

Страница 31: ...te grounded receptacle using wire nuts not included Place the connected receptacle back in the fireplace and pull excess cable back through the strain relief 6 Place the inner cover and receptacle in...

Страница 32: ...used must be resistant to the action of all gas constituents including LP gas Sealant should be applied lightly to male threads to ensure excess sealant does not enter gas lines Left side view Install...

Страница 33: ...ual shut o valve Test for leaks by applying a liquid detergent or soap solution to all joints Bubbles forming indicate a gas leak The pressure test tapping locations are shown in the figure at right A...

Страница 34: ...e Top panel orientation Overhanging part sits on top of side panel at each end 3 Let the top panel protruding part rest on the cut out of the upper part of the side panel 4 Repeat with the other side...

Страница 35: ...mber stamped on the bottom Some logs have pegs to help you place them on other logs Install the logs as follows 1 Install the steel platform around the burner as indicated The openings in the platform...

Страница 36: ...log slightly 6 Place log L6 from the rear groove on the top of L31 to the rear of the media platform L12 L30 L2 L31 Embers Groove L31 L6 7 Place log L1 from the front groove on the top of L31 and onto...

Страница 37: ...ers as these could be ingested by small children Vacuum area after installation L30 L2 L12 L31 L6 L1 L32 L4 Birch Log Kit 1505BLKV2 installed IMPORTANT Approved for use only with the ceramic embers pr...

Страница 38: ...fully unpack the kit as the logs are fragile 2 Install the steel platform around the burner as indicated The openings in the platform should be underneath 3 Place log 2965 as shown with the two pins i...

Страница 39: ...pread the vermiculite on the burner and the surrounding platform Do not pour too much to avoid blocking the burner ports NOTE Ensure the area within the pilot shield is clear of vermiculite 9 Place th...

Страница 40: ...f burner patting it gently with your hand to form a single layer to the approximate level of the top edge of the flange around the burner Do not place too much to avoid blocking the burner ports 4 Som...

Страница 41: ...indicated The openings in the platform should be underneath 1 2 3 x 29 Installed platform Installation Fuel Beds 3 Place the rocks around the burner on the media platform 4 Place the first twig 2 as...

Страница 42: ...ireplace area is clear of shale pieces as these could be ingested by small children Vacuum area after installation 6 Place twig 3 as shown Do not place it directly on the burner 7 Place the second twi...

Страница 43: ...log 1 as shown with the pin in the hole 4 Place log 2 from on top of log 1 across the burner to the front platform Installed platform 1 2 1 Split Wood Kit 1500SWK Material required Black steel platfor...

Страница 44: ...as shown from on top of log 4 to the platform 3 2 1 1 2 3 4 3 1 2 4 7 8 Place log 9 with the pin in the front platform as shown 9 Place log 8 on top of log 9 The left hand end of log 8 has a pin to in...

Страница 45: ...n Fuel Beds WARNING Choking Hazard Ensure that the fireplace area is clear of embers splinters as these could be ingested by small children Vacuum area after installation 11 Place log 11 on top of log...

Страница 46: ...m the front lower corner of the window re install it by sliding it between the glass and the frame as indicated WARNING The window unit must be correctly installed fastened and sealed after servicing...

Страница 47: ...3 Connect switch to auxillary 5 pin junction and power connection to jack 4 Run harness assembly to mounted position of junc tion box securing harness to framing using insu lated staples not included...

Страница 48: ...the snap connection load 4 AA alkaline bat teries into holder included with fireplace then feed back into junction box assembly Note Do not put batteries in the receiver only in the battery holder by...

Страница 49: ...he handset during the pairing sequence You will hear two short beeps confirming the pairing is done If you hear one long beep the pairing sequence has failed or the wiring is incorrect This is a one t...

Страница 50: ...crews with the included caps to finish the mounting Once mounted the holder is magnetic simply place the remote gently into the holder IMPORTANT The location of the remote control handset is important...

Страница 51: ...ed used altitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed pan...

Страница 52: ...Clean Installation Kit If you are installing the 1530CIK Clean Installation Kit you need to do it BEFORE the cement board 1 Break o tabs from each corner of the fireplace s front opening 8 tabs 2 at e...

Страница 53: ...Power POWER Battery Holder Battery Holder Connector RBWSK Battery Power RESET Button PANEL red yellow Receiver red Interruptor Block IGNITOR Combination Control Valve Antenna Main Valve Knob MAN Knob...

Страница 54: ...m Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmasters or others 2280 Series AF3 35L AF4 35L TM ALK33 TM A...

Страница 55: ...F 4F SV4F 949606001 Masonry Flashing TF 4MF 559FSK New Siding Flashing 658NSFK Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 94960608 Decorative...

Страница 56: ...t at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery opera...

Страница 57: ...flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appl...

Страница 58: ...WWRQ RQ KDQGVHW DLW YH PLQXWHV WR FOHDU RXW DQ JDV WKHQ VPHOO IRU JDV LQFOXGLQJ QHDU WKH RRU If you VPHOO JDV 6723 ROORZ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO gas go to the nex...

Страница 59: ...nly CAUTION Always check the re and pilot visu ally to ensure they are o AM ON OFF PM AM Thermostatic Mode Signal Indicator Child Proof Light Fan if included Program Mode Temperature Time Auxiliary Fe...

Страница 60: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 61: ...nly works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light turn...

Страница 62: ...WiFi the handset will display APP Manual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset t...

Страница 63: ...To con rm press ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes...

Страница 64: ...a short circuit Low Battery Receiver With low battery power in the battery holder the system shuts o the re completely This will not happen if the power is completely interrupted Seven Day Shut Off Th...

Страница 65: ...no pilot ame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery s...

Страница 66: ...gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can turn the pilot on or o and you can i...

Страница 67: ...manual Planning Installation Linear with HeatShift Instructions for use with the following Valor Heater Models 1500 1600 1700 and 1800 J or K Incompatible with earlier models 1500I 1600I and 1700I WAR...

Страница 68: ...n Plates 2 for wall valance discharge ONLY LDK9 30 Plenum 7 3 4 197 mm LDK1 48 x 2 LDK4 38 x 2 LDK3 2 14 x 6 2 14 x 6 grilles included white 4 take off collars included 4 take off collars included 4 t...

Страница 69: ...um 2 ply Flex Kit 2 x 10 0 lengths may be cut to required length LDK10 30 Finishing Frame to use with LDK9 3 5 8 92 mm 3 5 8 92 mm LDK6 2 10 x 5 aluminum ex LDK5 supplied separately 38 frame white LDK...

Страница 70: ...he termination duct plates are approved for vertical upward discharge ONLY DO NOT install plenum or termination plates in oor or ceiling DO NOT COVER OR PLACE objects in front of or on top of air outl...

Страница 71: ...le or rigid 5 diameter UL 181 Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 clearance to ceiling Min 30 Max 12 0 See table for offsets Linear 32 3 8 LX2 33 1 4 Linear 8 1 2 LX2 5 1 4 Linear...

Страница 72: ...Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 opening required at ceiling Min 30 Max 12 0 6HH WDEOH IRU R VHWV Min 14 32 3 8 8 1 2 14 1 2 9 3 8 Ceiling Min 1 clearance to combustibles aroun...

Страница 73: ...2 0 Maximum allowable Horizontal Offset X offset for take off that s furthest away Ceiling LDK 1 LDK 3 or LDK 4 Min bend radius Top of fireplace Min 1 clearance to combustibles around pipes Support ho...

Страница 74: ...g bracket and 1 1 2 standoff mounting bracket and 1 2 standoff 3 1 2 standoff 3 5 8 7 7 8 11 1 2 Top View Front View Right Side View LDK 4 38 LDK 4 5 dia collars 4 C L 8 14 8 4 4 3 3 5 8 7 7 8 11 1 2...

Страница 75: ...ounting bracket and 1 2 standoff 8 11 1 2 1 2 wallboard 1 2 standoffs Front View Right Side View 1 2 standoff LDK 9 30 LDK 9 5 dia collars 4 C L 7 1 16 7 1 16 7 1 16 4 3 8 4 3 8 3 9 1 2 Front View Top...

Страница 76: ...ensions 5 dia collars 4 C L 7 4 1 2 9 3 4 9 3 4 4 1 2 19 1 2 2 1 2 13 1 2 16 19 1 2 9 3 4 9 3 4 Stand offs fold down for shipping Warning Label Stand offs Front View Top View Right Side View Perimeter...

Страница 77: ...ngs LDK9 Minimum 31 4 Min 1 below QLVKHG FHLOLQJ LDK 1 49 LDK 4 39 LDK 1 LDK 4 LDK 3 LDK 3 15 4 5 LDK 1 13 LDK 4 11 UDPLQJ RQ HGJH Top of plenum VXSSRUW UDPLQJ RQ HGJH Min 1 below QLVKHG FHLOLQJ 8 C L...

Страница 78: ...ible cavity dimensions Note Min cavity dimensions may be dictated by LDK plenum when installing across corners Min 1 2 clearance to combustibles at ends See detail LDK 1 49 LDK 4 39 LDK 3 15 LDK 9 31...

Страница 79: ...s all around pipes Plenum support wood Maintain 1 clearance to pipes Framing on edge 1 1 2 min clearance to combustibles top Ceiling Min 2 1 2 clearance to ceiling 1 2 1 2 min clearance to combustible...

Страница 80: ...around pipes 2 x 4 on edge to support plates as necessary maintain 1 clearance to pipes DOO QLVK UHTXLUHG to form plenum above duct termination plates LDK 7 Duct Termination Plates 2 for horizontal in...

Страница 81: ...2 19 1 2 16 13 1 2 4 4 Stand off Non combustible zone above plates Perimeter of plates may be trimmed to suit installation Combustible framing allowed below plates 5 dia pipes maintain 1 clearance to...

Страница 82: ...HU WKDQ SOHQXP SRVLWLRQ GLD SLSLQJ LDK1 or LDK4 plenum LDK9 cannot be installed with1270RBK See HeatShift System manual in Appendix of fireplace installation manual Universal take off supplied with 12...

Страница 83: ...kept behind this line 23 3 4 29 3 4 33 3 4 45 NOTE These Mantel Clearances apply ONLY when HeatShift System is installed Mantel Height from Bottom of Unit COMBUSTIBLE Mantel Clearances Linear applian...

Страница 84: ...ase be removed to allow the hot air ow to convect upwards into ducts installed on the replace Remove the convection ba e from the appliance It is held in place by screws located right behind the upper...

Страница 85: ...O U R 4 t a k e o f f s M U S T B E C O N N E C T E D T O P L E N U M S Install HeatShift collars 1 Remove the four cover plates on top of the appli ance case 6 screws each 1500 1700 1800 J or K 1500...

Страница 86: ...UL 181 Class 1 approved air duct to each of the collars and secure it with gear clamps provided DO NOT SPLICE DUCTS 5 Attach the top of the pipe sections to the plenum securing them with the gear clam...

Страница 87: ...es posi tions Support horizontal sections every 24 inches 6 Continue with the replace installation 2 stand offs per plate Description Part no LDK1 48 Quad Hot Air Plenum Kit 48 x 2 quad plenum 4005476...

Страница 88: ...07 37 Burner mounting bracket 4006918 38 Burner mount 4007223 39 Air shutter stopper 4008004 40 Orifice aeration block 4007702 Description Part No 40 Gas orifice 36 natural gas 4007000 36 Gas orifice...

Страница 89: ...les 2 4003087 83 Grade 1A vermiculite bagged 5 5 cups 4002940 84 Rocks Shale Set 1514RSS 85 LH twig 4001827 86 LH twig short 2 4001827S 87 RH twig 2 4001828 88 Grey Rock S4 A 6 4002338 89 Dark Grey Ro...

Страница 90: ...62a 62b 62c 62d 62e 62f 62g 62h 62i 52 51 59 58 57 55 54 56 105 1 2 3 5 5 4 5 5 9 9 6 6 6 6 8 8 7 10 10 20 22 23 21 60 61 14 15 16 13 12 12 13 17 11 19 19 18 11 24 25 26 32 33 34 36 35 38 37 46 47 48...

Страница 91: ...86 87 89 90 91 92 93 94 97 96 95 6 6 4 2 2 4 2 2 1514RSS 1500DGM 2 100 101 1500SWK 104 1 2 3 4 7 8 9 10 11 1615FBL 1625RGL 63 71 99 103 102 65 66 67 84 2965 3720 2939 2967 2966 2100DWK 83 72 73 76 77...