Valor 700MNGK Скачать руководство пользователя страница 1

WARNING

This conversion kit shall be installed by 

a quali

fi

 ed service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a 

fi

 re, explosion 

or production of carbon monoxide 

may result causing property damage, 

personal injury or loss of life. The 

quali

fi

 ed service agency is responsible 

for the proper installation of this kit. The 

installation is not proper and complete 

until the operation of the converted 

appliance is checked as speci

fi

 ed in the 

manufacturer’s instructions supplied with 

the kit.
Use this manual in conjunction with the 

installation manual supplied with the 

appliance.

700MNGK / 700MPGK Gas Conversion Kit

Use with Valor G3.5 700M Heater Models ONLY

INSTALLATION MANUAL

G3.5 Series

4008354-03

©2021, Miles Industries Ltd.

Kit Contents

• 1 Pilot injector
• 1 Main burner injector elbow
• 1 Air shutter
• 1 Pilot shield
• 1 Minimum rate bypass screw
• 1 Set of conversion labels

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module
•  Small (jewelers size) 

fl

 at blade screwdriver, to set 

pressure

• Small 

fl

 at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove bypass screw
•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

•  Manometer, to set pressure

Speci

fi

 cations

*

b

This appliance is certi

fi

 ed for use from 0–4500 feet. For 

altitudes above 4500 feet, see local codes.

Model 

700MN

700MP

Gas

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

26,000

26,000

Input Minimum (Btu/h)

13,000

11,000

Manifold Pressure (in w.c.)

3.5”

10”

Minimum Supply Pressure (in w.c.)

5”

11”

Maximum Supply Pressure (in w.c.)

10”

14”

Main Burner Injector Marking

750

260

Pilot Injector Marking

51

30

Min. Rate By-Pass Screw

175

105

Содержание 700MNGK

Страница 1: ...els ONLY INSTALLATION MANUAL G3 5 Series 4008354 03 2021 Miles Industries Ltd Kit Contents 1 Pilot injector 1 Main burner injector elbow 1 Air shutter 1 Pilot shield 1 Minimum rate bypass screw 1 Set of conversion labels Tools Required Wrenches to disconnect gas line Phillips screwdriver to remove burner module Small jewelers size flat blade screwdriver to set pressure Small flat blade screwdriver...

Страница 2: ...lled trims fronts and doors 3 Remove the window 4 If the fireplace is already installed a Remove the fuel bed Be careful with fuel bed as components are fragile b Remove liner panels c Disconnect the exhaust slide screws 2 screws at top front of unit d Pull the unit out while disconnecting the exhaust slide Leave the vents and slider hanging in the chimney 5 Remove left shroud 2 screws 6 Remove th...

Страница 3: ...2 Unscrew the nut at the end of the burner fuel supply line and lift the burner and supports out of the fireplace complete with injector elbow at tached 3 Unscrew and disengage the injector elbow Be aware that four pieces sit between the elbow and the burner do not drop them 4 Exchange injector elbow from kit verifying the new injector before you install see Specifications table on page 1 The inje...

Страница 4: ...uld not be removed 3 Unscrew the pilot injector using an Allen key Dis card the old pilot injector 4 Replace with the appropriate pilot injector see Specifications table on page 1 the pilot injector number is stamped on the barrel Screw in the new injector Pilot hood U clip 5 Refit the pilot hood by pushing down on it mat ing its notch and key at the base Ensure that it snaps into position 6 Insta...

Страница 5: ...nnection joints that were taken apart and reassembled Bubbles forming indicate a gas leak Bypass screw Valve WARNING NEVER use an open flame to check for leaks Correct any leak detected immediately Set the Manifold Pressure 1 Fit a manometer to the manifold pressure test tap on the valve see figure below 2 Light the appliance and turn the control to full input 3 Adjust the pressure adjustment scre...

Страница 6: ...he firebox 1 Locate the aeration adjustment lever 2 Adjust the aeration lever as required Depending on fuel bed used altitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed liners and window installed and evaluating the flame picture after a 15 minute warm up Airshut...

Страница 7: ...N Série G3 5 Contenu du kit 1 Injecteur de veilleuse 1 Injecteur coude du brûleur 1 Obturateur d air 1 Écran de veilleuse 1 Vis d indice minimum 1 Ensemble d étiquettes de conversion Outils requis Clés à tuyaux pour débrancher la conduite de gaz Tournevis Phillips pour enlever le module du brûleur Petit tournevis à lame de bijoutier pour régler la pression Petit tournevis à lame pour libérer la pr...

Страница 8: ...oyer est déjà installé a Enlevez le lit de combustion Faites attention car les pièces sont fragiles b Enlevez les panneaux intérieurs c Détachez l appareil de sa plaque d évent 2 vis au dessus de la caisse de l appareil d Tirez l appareil hors de la cavité en enlevant la plaque d évent Elle demeure raccordée aux conduits dans la cheminée 5 Enlevez le support de devanture bordure gauche 2 vis 6 Enl...

Страница 9: ... vis 2 En soutenant l injecteur coude dévissez l écrou retenant la conduite de gaz pour la débrancher Sortez le rail du brûleur de la boîte de foyer avec l injecteur coude toujours en place 3 Dévissez et enlevez l injecteur coude du brûleur en faisant attention de ne pas échapper les qua tre petites pièces situées entre l injecteur et le brûleur 4 Remplacez l injecteur par celui fourni avec la tro...

Страница 10: ...lleuse pour l enlever 3 Enlevez l injecteur de la veilleuse avec une clé Allen et jetez le 4 Remplacez le avec l injecteur approprié voir le tableau Spécifications à la page 7 Installez le nouvel injecteur et serrez le Capuchon Attache en U 5 Réinstallez le capuchon de la veilleuse alignant la fente du capuchon à la clé dans sa base et en pous sant dessus Assurez vous qu il s enclenche correcte me...

Страница 11: ...JAMAIS UTILISER une flamme vive pour vérifier s il y a des fuites Corrigez immédiatement toute fuite détectée Réglez et vérifiez la pression d admission 1 Fixez un manomètre à la connexion de vérification de pression d admission sur la soupape voir l image ci dessous 2 Allumez l appareil et tournez le contrôle pour apport maximal 3 Réglez la vis d ajustement de pression sur la soup ape à l aide d ...

Страница 12: ...aération La nécessité de changer l aération devrait être détermi née seulement après avoir fait fonctionner l appareil avec le lit d alimentation les panneaux et la fenêtre installés et après avoir évalué les flammes suivant un réchauffement de 15 minutes Obturateur ouvert Obturateur fermé Conçue et fabriquée par pour Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC CANADA V7H 3B1...

Отзывы: