background image

1

Note: 

This kit must be installed or serviced by a qualifi ed installer, service agency or the gas 

supplier. These instructions are to be used in conjunction with the main installation instructions for 

the above listed models.

WARNING: If the information in these instructions is not followed exactly, a fi re or explosion 

may result causing property damage, personal injury or loss of life.

GROUNDING:

 This power supply must be installed and grounded in accordance with local codes, 

or in the absence of local codes, with the current Canadian Electrical Code CSA C.1. or in the 

USA the National Electrical Code ANSI/NFPA0 latest edition.

DESCRIPTION OF SYSTEM

The models listed above have been designed to accommodate the installation of an air circulation 

fan. Operated by a variable speed control and a thermally actuated switch, the fan is designed to 

boost the natural convection through the heater; this may be a desirable feature dependent on the 

fi replace location and room layout. The circulating fan may be installed before the heater installation 

or as a retrofi t at a later date.

OPERATION

The fan is designed for automatic operation using a thermal switch. It will take approximately 10-15 

minutes for the appliance to warm up and allow the switch to activate the fan. To operate the fan, 

rotate the speed control knob clockwise from OFF to HIGH. Further rotation will control the fan speed, 

once the automatic thermal switch has been activated. If the fi re is turned off, the fan will continue 

to operate until the thermal switch cools, unless the speed control is manually turned to the OFF 

position.

Should electrical power fail, the heater operation will remain unaffected. 

ELECTRICAL REQUIREMENTS

The fan kit requires a power supply of 

120 Volts, 1 phase, 60 Hz. Full load current is less than 1 

amp

.

4000510-04

555CFK CIRCULATING FAN KIT

INSTALLATION and OPERATING INSTRUCTIONS

CSA approved for use only with:

Valor models 530 I, RetroFire RF24 and Madrona MF28

Содержание 555CFK

Страница 1: ...rough the heater this may be a desirable feature dependent on the fireplace location and room layout The circulating fan may be installed before the heater installation or as a retrofit at a later date OPERATION The fan is designed for automatic operation using a thermal switch It will take approximately 10 15 minutes for the appliance to warm up and allow the switch to activate the fan To operate...

Страница 2: ...able Retainer Thermal Switch and Lead 6 0 Grounded Plug Fan Kit Components FAN KIT COMPONENTS The complete 555CFK kit contains the following Fan motor unit assembled to fan mounting bracket c w wiring harness speed control junction box thermal sensor switch and 6 cord set Control box mounting screw and cable retainer Unit mounting screws 2 ...

Страница 3: ...l base of the fireplace enclosure is supported If the metal base can flex up and down it may be a source of vibration noise when the fan unit is installed Now is the time to correct this Install the fan according to the guidelines of the next pages TESTING THE FAN UNIT AFTER INSTALLATION Although the fan and controls are factory tested to ensure proper operation a check should be performed after t...

Страница 4: ...x with the wires running behind and secure to the rear wall using the two screws provided Secure the thermally actuated switch to the side of the firebox using 2 screws Use the U shaped self adhesive cable retainer to hold the thermal switch wiring to the bottom of the appliance and away from the fan inlet 5 6 Raise this tab Fasten blower control to engine tab using one screw Run Power Cord out le...

Страница 5: ...the fan mounting bracket and reinstall in reverse position to the fan assembly The mounting bracket is originally supplied set up for heater model 530 application With the burner module removed install the fan unit into the rear convection channel on heater 1 Unscrew 3 screws and remove fan mounting plate Flip bracket over and reinstall using screws through 3 lower holes Tabs facing forward Slip F...

Страница 6: ...upport leg if desired Fasten the thermal switch to underside of burner module using 2 screws Test the fan operation as indicated on page 3 of this manual Finish the assembly of the fireplace as indicated in the installation manuals provided with the fireplace s engine front and trim 5 6 Fasten Fan Control Box to lower RH Support Leg using 1 screw Fasten Thermal Switch to underside of burner module...

Страница 7: ...to the base of the stove from underneath 1 5 Fasten Thermal Switch to underside of burner module using 2 existing screws Fan control box position Fan control box bracket Unscrew 3 screws and remove fan mounting plate Fix the thermoswitch to the underside of the burner plate behind the pilot area with 2 screws taken from the burner plate Test the fan operation as indicated on page 3 of this manual ...

Страница 8: ...fied gas appliance service person Over time it may be useful to clean the fan blades themselves for dust accumulation To do this it is necessary to remove the burner assembly This must be done by a qualified gas appliance service person WIRING DIAGRAM Warning Electrical Grounding Instructions This appliance is equipped with a three prong grounded plug for your protection against shock hazard and m...

Страница 9: ...OR IMPLIED INCLUDING THE WARRANTY OF MERCHANTABILITY OF FITNESS FOR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES MILES INDUSTRIES LTD DOES NOT ASSUME NOR HAS IT AUTHORIZED ANY PERSON INCLUDING ITS SALES REPRESENTATIVES TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OR USE OF THE MODEL 555CFK CIRCULATING FAN KIT A qualified installer in accordance with the ins...

Страница 10: ...menter la convection na turelle du foyer cette option peut être désirable selon l emplacement du foyer Le ventilateur peut être installé au moment de l installation du foyer ou à une date ultérieure FONCTIONNEMENT Ce ventilateur est conçu pour fonctionner automatiquement avec un interrupteur thermique Il faudra approximativement 10 à 15 minutes pour réchauffer l appareil et permettre à l interrupt...

Страница 11: ...itesses l interrupteur thermique et le cordon d alimentation de 6 pieds Serre fil et vis à métal Vis de montage du ventilateur 2 Boîte de contrôle de vitesses Bornes Ventilateur et plaque de montage Bornes Vis à métal 2 Vis auto taraudeuse 1 Serre fil adhésif Interrupteur thermique et fil Cordon d alimentation de 6 pi avec fiche de mise à la terre Éléments ...

Страница 12: ...bilité peut devenir une source de vibration ou de bruit lors du fonctionnement du ventilateur Faites les corrections qui s imposent à ce moment ci Installez le ventilateur selon les directives des pages suivantes VÉRIFICATION DU FONCTIONNEMENT DU VENTILATEUR APRÈS INSTALLATION Le ventilateur a été testé lors de sa fabrication Cependant il est recommandé de vérifier son bon fonctionnement au moment...

Страница 13: ...d une vis Faites passer le cordon d alimentation au coin arrière gauche Ramenez les fils derrière le ventilateur Fil de l interrupteur thermique Placez le ventilateur à l arrière de la boîte de foyer devant ses fils et fixez le à la paroi arrière avec les deux vis fournies Fixez l interrupteur thermique au côté gauche de la boîte de foyer avec deux vis Utilisez le serre fil adhésif pour maintenir ...

Страница 14: ...c le foyer Valor 530 1 Dévissez et enlevez la plaque de montage du ventilateur Inversez la plaque et revissez la dans les trous du bas Languettes orientées vers l avant Glissez la plaque de montage dans la canalisation de convection et alignez la aux trous de fixation de la paroi intérieure Plaque de montage fixée dans la canalisation de convection Glissez la plaque de montage fixée au ventilateur...

Страница 15: ...se Fixez l interrupteur thermique sous le module du brûleur à l aide de 2 vis tirées du module 5 Vérifiez le bon fonctionnement du ventilateur selon la procédure indiquée à la page 12 Terminez l assemblage du foyer selon les directives des guides d installation fournis avec les foyer devanture et bordure 6 INSTALLATION MODÈLE RETROFIRE RF24 Fixez la boîte de contrôle du ventilateur à la patte droi...

Страница 16: ...eil 1 5 Position de la boîte de contrôle du ventilateur Support pour la boîte de contrôle Fixez l interrupteur thermique au dessous de la plaque du brûleur à l aide de deux vis tirées de la plaque Arrière de la boîte du foyer Ventilateur Dévissez et enlevez la plaque de montage du ventilateur À l aide de 2 vis tirées de la plaque du brûleur fixez l interrupteur thermique en dessous de la plaque du...

Страница 17: ...ppareils au gaz Avec le temps l accumulation de la poussière peut rendre nécessaire le nettoyage des lames du ventilateur Pour faire ce nettoyage le module du brûleur devra être enlevé Cette opération ne peut être effectuée que par un technicien qualifié spécialisé dans l entretien d appareils à gaz SCHÉMA DES CONNEXIONS Mise en garde Directives de mise à la terre Pour votre protection contre les ...

Страница 18: ...ISATION DE L APPAREIL À DES FINS PARTICULIÈRESAINSI QUE TOUTESAUTRES OBLIGATIONS OU RESPONSABILITÉS MILES INDUSTRIES LITD N ASSUME NI N AUTORISE AUCUNE PERSONNE INCLUANT SES REPRÉSENTANTSAUX VENTES OU DÉTAILLANTS MARCHANDS AUTORISÉS D ÉTENDRE OU D ASSUMER EN SON NOM AUCUNE AUTRE OBLIGATION OU RESPONSABILITÉ EN RELATION À LA VENTE OU L UTILISATION DU VENTILATEUR DE CIRCULATION D AIR 555CFK Un insta...