background image

© 

Baxi Heating U.K. Limited 2010.

5133756/03

INSTALLER: Please leave this guide with the 

owner

Model 541

ROOM SEALED RADIANT / CONVECTOR
GAS FIRE

Fitted with one of the following fascia.

Camden, Seattle, Sonnet

or

Ultimate.

(GC No. 32-032-64)

We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our

Valor Fires Technical Helpline

will

be pleased to help.
Telephone 

0844 8711 565 

(National

call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone

0044 844 8711 565.

INSTALLER AND OWNER GUIDE

Содержание 541

Страница 1: ...r Ultimate GC No 32 032 64 We trust that this guide gives sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor...

Страница 2: ...wing address The Company Secretary Baxi Heating UK Limited Brooks House Coventry Road Warwick CV34 4LL Warning Any person who does any unauthorised act in relation to a copyright work may be liable to...

Страница 3: ...ty system accepted by the British Standards Institute The Highest Standards Valor Fires is a member of SBGI and HHIC Heating and Hot water Industry Council that work to ensure high standards of safety...

Страница 4: ...INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 40 TO 51 INSTALLER GUIDE Page 4 Baxi Heating U K Limited 2010...

Страница 5: ...ation 13 5 6 The surround 13 5 7 Hearth plinth requirements 14 5 8 Fireplace clearances 15 5 9 Installation options 16 5 10 Terminal guard and terminal clearances 16 6 UNPACKING AND PRELIMINARY CHECKS...

Страница 6: ...Check control operation 33 14 3 Checking inlet pressure 34 15 FASCIA FITTING 35 16 FINAL REVIEW 36 17 SERVICING PARTS REPLACEMENT 37 17 1 To remove fascia 37 17 2 To remove window unit 38 17 3 To remo...

Страница 7: ...with the palm of the hand Do not use the tips of fingers for support Always keep the fire as close to the body as possible This will minimise the cantilever action Use gloves to provide additional gr...

Страница 8: ...seen by removing the lower front casting fire front Before continuing with the installation of this appliance please complete the information on the last pages of the owner guide Page 8 Baxi Heating...

Страница 9: ...87 The efficiency value may be used in the UK Government s Standard Assessment Procedure SAP for energy rating of dwellings The conversion of net efficiency to gross was achieved by multiplying the ne...

Страница 10: ...may differ from that shown Key Description Model Ultimate Sonnet Camden Seattle A Appliance height mm 607 607 B Appliance width mm 487 487 C Appliance depth into room mm 140 172 D Minimum mandatory c...

Страница 11: ...Figure 2 Recess and flue hole dimensions INSTALLER GUIDE Page 11 Baxi Heating U K Limited 2010 Figure 1 Continued...

Страница 12: ...tandards Scotland Regulations issued by the Scottish Executive In Northern Ireland the current edition of the Building regulations Northern Ireland issued by the Department of the Environment for Nort...

Страница 13: ...ve the top surface of the hearth or finished floor 5 5 Fireplace preparation 5 5 1 The front face of the fireplace should be reasonably flat over the area covered by the convection box top and side fl...

Страница 14: ...lled on any hard surface This surface should be level and sufficiently flat to enable the bottom of the fascia fire front castings to be aligned horizontally Any unevenness Uneven tiles Cotswold stone...

Страница 15: ...tible projections for all normal installations Installation into an unusually tightly restricted recess however could cause the temperature of the appliance surfaces to become unacceptably high 5 8 2...

Страница 16: ...g If in doubt seek expert building advice Lintel construction details are given in section 8 of this guide This appliance must not be recessed into a combustible wall 5 9 2 A concealed gas supply conn...

Страница 17: ...aves 300mm F Below balconies or car port roof 600mm G From a vertical drain pipe or soil pipe 300mm H From an internal or external corner 600mm I Above ground roof or balcony level 300mm J From a surf...

Страница 18: ...for the purpose of accommodating a built in element such as a window frame or door frame See figure 5 The reference to external corners does not apply to building protrusions not exceeding 450mm such...

Страница 19: ...top to clear the slots in the convection box hood and then lift clear Place the fascia in a safe place away from your immediate work area Window and ceramic fuel effect removal Unscrew and remove the...

Страница 20: ...rial Flexible pipe must not be used Concealed supply pipe connecting from rear of the appliance Before the appliance is installed it will be necessary to extend the supply line so that it will project...

Страница 21: ...wall for the appliance should be within the sizes shown in figure 2 The bottom of the recess should be at the same level as the finished floor in front of the appliance A lintel may be required above...

Страница 22: ...re 11 An alternative to rockwool above the opening is to seal across the top of the cavity with Superlux board or equivalent The board should slope downward to the back so that any moisture will be ch...

Страница 23: ...hole to ensure that it is in the brickwork and not in mortar If it is in mortar it is advisable to reposition the hole approximately 25mm away Make sure that the minimum side clearances and height ar...

Страница 24: ...y 10mm undersize so that the sleeve will be forced through the layer A recommended technique for cutting the inner leaf is shown in figure 12 Fit the non combustible sleeve to the inner leaf The sleev...

Страница 25: ...he two eyebolts 9 FLUE AND TERMINAL INSTALLATION 9 1 Cutting flue to size For outset appliances with surround or spacer Measure the total wall thickness from the outside surface of the wall to the ins...

Страница 26: ...INSTALLER GUIDE Page 26 Baxi Heating U K Limited 2010 Figure 15 Flue unit installation Timber framed building Figure 14 Flue unit installation Brick etc building...

Страница 27: ...ty See figure 15 The drip collar can be made by wrapping a non corrosive wire round the flue or moulding a bead of mastic round the flue Case fixing to wall Offer the fire complete with flue unit thro...

Страница 28: ...plete the supply pipe connection For concealed rear connection the pipe run should have been extended as in section 7 of this guide Connect the inlet T connector to the appliance inlet pipe For Side C...

Страница 29: ...mic coal should locate on the horizontal faces but behind the vertical faces of the two location brackets positioned at the front of the burner module See figure 18 The coals should be positioned so t...

Страница 30: ...nting to the top Locate coal C as shown in figure 21 5 Hold coal D upright with the arrow pointing to the top Locate coal D as shown in figure 22 6 Hold coal E upright with the arrow pointing to the t...

Страница 31: ...pebble base should locate on the horizontal faces but behind the vertical faces of the two location brackets positioned at the front of the burner module See figure 24 The pebbles should be positione...

Страница 32: ...ing to the top Locate pebble C as shown in figure 27 5 Hold pebble D upright with the arrow pointing to the top Locate pebble D as shown in figure 28 6 Hold pebble E upright with the arrow pointing to...

Страница 33: ...hand control knob fully clockwise Push in the right control knob and while keeping it depressed turn anticlockwise through the ignition position marked and up to the pilot position marked The spark s...

Страница 34: ...mbar 8in w g inlet pressure and no further adjustment is necessary The burner pressure should be checked at the pressure test point located on the inlet T connector See figure 31 The pressure check sh...

Страница 35: ...Locate the two screw heads at the rear top corners of the casting through the keyhole slots at the inner sides of the fascia If the screw heads do not project enough or project too far the screws can...

Страница 36: ...ront cover as a reminder to the customer 7 Advise the customer that the pilot flame can be viewed to ensure that it is alight Show the user where to view the pilot and point out the illustration in th...

Страница 37: ...hene bag clearly labelled as RCF waste RCF waste is classed as a stable non reactive hazardous waste and may be disposed at a landfill licensed to accept such waste Protective clothing is not required...

Страница 38: ...See section 17 1 Remove the window unit See section 17 2 Lift out the ceramic fuel effect and rear wall See section 17 3 Isolate the gas supply using the inlet T connector on the appliance Unscrew th...

Страница 39: ...ossibility of damaging the lead connection Unscrew the nut connecting the pilot to the pilot pipe Unscrew the thermocouple at the rear of the gas valve Unscrew the two screws securing the pilot to the...

Страница 40: ...OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 47 TO 51 Page 40 Baxi Heating U K Limited 2010...

Страница 41: ...MAINTENANCE 47 WARRANTY AND SERVICE 47 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble free service This guide...

Страница 42: ...a shelf deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See figure 1 Do provide a minimum clearance of 51mm each side of the fire for servicing access Do provide...

Страница 43: ...the flue terminal on the outside wall free from all obstructions and blockages Don t hang clothing towels or any other fabrics over the fire Don t use the fire without the glass window panel in posit...

Страница 44: ...tion Model Ultimate Sonnet Camden Seattle A Appliance height mm 607 607 B Appliance width mm 487 487 C Appliance depth into room mm 140 172 D Minimum mandatory clearance to combustible surfaces projec...

Страница 45: ...ill shut off the gas supply if for any reason the pilot goes out This device incorporates a fixed probe which senses the heat from the pilot flame If the probe is cool the device will prevent any gas...

Страница 46: ...s for burner flame adjustment Turning it anticlockwise should gradually increase the flame height and heat output Turning clockwise reduces the flame height and heat output The burner flame control do...

Страница 47: ...ation card or calling our free telephone registration line on 0800 032 72 44 It is also a requirement of the warranty that the fire has an annual service every 12 months in accordance with the install...

Страница 48: ...nd to be of faulty manufacture Free of charge replacement of the complete unit providing the failure is related to a manufacturing fault that cannot be repaired or is uneconomic to repair What this wa...

Страница 49: ...OWNER GUIDE Page 49 Baxi Heating U K Limited 2010...

Страница 50: ...er Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number To be completed by Installer Page 50 Ba...

Страница 51: ...number Can be found on the information label See figure 5 Fascia name Block Capitals 5 4 1 OWNER GUIDE A LABEL CONTAINING THE SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX A LABEL CONTAINING THE...

Страница 52: ...Baxi Heating U K Limited 2010...

Отзывы: