TECHNIC

AL SPECIFIC

ATIONS

FAN INPUT POWER

Input power (total) (W)

Air flow (max) (dm3/s)

SFP =

SFP rate (Specific Fan Power)

recommended value <1.8 (kW m

3

/s)

Volume flow rate

Power (W)

SUPPLY/EXTRACT AIR VOLUMES

Volume flow rate 

(dm

3

/s)

Pressure loss in ducts. Total pressure (Pa)

extract air

supply air

0

50

100

150

200

250

300

0

10

20

30

40

50

60

70

80

90

100

80 %

70 %

60 %

50 %

40 %

30 %

20 %

10 %

100 %

L

SFP 1,0  

SFP 1,5 

SFP 1,2 

0

36

72

108

144

180

216

252

m³/h

(l/s)

dm³/s

288

324

360

30 %

50 %

10 %

20 %

40 %

60 %

70 %

80 %

100 %

90 %

0

20

40

60

80

100

120

140

160

180

200

0

10

20

30

40

50

60

70

80

90

100

0

36

72

108

144

180

216

252

288

324 360 m³/h

(l/s)

dm³/s

Sound power level in the supply air duct (one duct)  

by octave band L

w

, dB

Sound power level in the extract air duct (one duct)  

by octave band L

w

, dB

Adjustment position

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

90

100

10

20

30

40

50

60

70

80

90

100

Medium

frequency

of the

octave 

band

Hz

63

54

64

69

74

76

80

84

87

87

86

51

56

63

66

70

73

76

78

79

79

125

50

56

62

66

70

73

77

80

82

81

43

46

52

55

60

63

66

68

71

71

250

46

54

59

63

66

69

72

75

77

77

33

38

44

47

51

55

58

61

63

63

500

40

48

54

57

61

63

66

68

70

71

29

38

44

47

51

54

57

59

61

61

1000

34

44

51

55

60

62

64

66

68

68

24

32

38

42

46

49

52

55

57

57

2000

21

35

44

49

54

57

61

63

66

66

13

17

24

29

33

36

39

42

44

44

4000

17

23

34

41

47

51

55

58

61

61

17

17

18

20

23

26

29

32

34

34

8000

21

21

26

34

42

47

52

56

59

59

21

21

21

21

21

22

23

25

27

27

L

W

,dB 

L

WA

, dB(A)

56

65

70

75

78

81

85

88

89

88

52

56

64

66

71

74

76

79

80

80

42

50

57

61

64

67

70

73

75

75

33

39

45

48

52

55

58

61

63

63

Sound pressure level coming through the envelope of the unit in the room in which it is installed (10m² sound absorption)

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

90

100

L

pA

, dB (A)

24

28

34

33

37

41

44

46

48

48

SOUND VALUES

TECHNICAL SPECIFICATIONS

Product title

Vallox 096 MV R

Vallox 096 MV L

Product number

3474450

3474550

Air volumes

 

Supply air

 

Extract air

84 dm

3

/s, 100 Pa

88 dm

3

/s, 100 Pa

Fans

 

Supply air

 

Extract air

0.119 kW 0.9 A EC

0.119 kW 0.9 A EC

Post-heating

Electrical resistor, 900 W

Electrical connection

230 V, 50 Hz,  5.1 A power plug

Pre-heating

Enclosure protection class

IP34

Additional heating

Heat recovery bypass

Automatic

Filters

 

Supply air

 

Extract air

ISO Coarse > 75 % + ISO ePM₁

ISO Coarse > 75 % 

Specific energy consumption (SEC)

 

in a cold climate 

 

in a temperate climate

A+

A

Operating efficiencies*

 

 

Annual efficiency

 

Supply air efficiency

 

Specific Fan Power (SFP)

77 %

86 %

1.33 kW/m3/h (59 dm3/s)

Dimensions

 (w x h x d) 

600 x 545 x 428 mm

Weight

53 kg

*Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2012.

You can calculate the sound values for each operating point with the Vallox MySelecta software.

Содержание A3712-1

Страница 1: ...Manual Model Vallox 096 MV Vallox 110 MV Vallox 145 MV Type A3722 A3702 A3712 1 Document D5326 Valid from 15 10 2021 Updated 15 05 2023 Ventilation units MANUAL...

Страница 2: ...tallation of the Vallox Silent Klick siphon 10 Space required by the alternative Vallox Silent Klick siphon installation method elbow 10 Vallox 096 MV Vallox 110 MV and Vallox 145 MV 10 Dimensions and...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...s be installed on the floor by using a floor rack NOTE The standard equipment and available accessories vary from country to country DANGER Indicates a hazard that will result in death or serious inju...

Страница 5: ...trol panel The ventilation unit setup can also be completed without a MyVallox control panel For instructions please go to https vallox techmanuals info ValloxMV ENG help webhelp See instructions prov...

Страница 6: ...behind the extract air duct 8 R model in the figure MAIN PARTS Vallox 096 MV Vallox 110 MV and Vallox 145 MV Safety switch 9 Internal humidity sensor 10 Internal carbon dioxide sensor 10 Control pane...

Страница 7: ...in which case the ceiling can be 20 mm below the top of the white covering strip Insulate the ducts against condensation also between the unit and the ceiling mounting plate Mounting the ceiling moun...

Страница 8: ...unting plate on top of the ceiling NOTE Remember to make a service door in the ceiling so that the cables and the connection box can be accessed The distance between the service door and the ceiling m...

Страница 9: ...he base fit in the holes at the bottom of the unit Mount the ventilation unit on the wall with a mounting plate as shown in the adjacent figure Make sure that the unit is horizontally level after moun...

Страница 10: ...is used the ring seal and the locking part must be moved to the pipe connection part that is mounted on the wall INSTALLATION Dimensioning figure and space required for installation of the Vallox Sil...

Страница 11: ...s are mirrored 5 Bypass damper of the HR cell 6 Coarse filter for supply air 7 Coarse filter for extract air 8 Post heating resistor behind the extract air duct 9 Safety switch Air flow measurement po...

Страница 12: ...ing resistor behind the extract air duct 9 Safety switch 10 Additional heating resistor behind the extract air duct Air flow measurement points A Supply air B Extract air Measurement points after the...

Страница 13: ...ed 6 Coarse filter for supply air 7 Coarse filter for extract air 8 Post heating resistor behind the extract air duct 9 Safety switch 10 Additional heating resistor behind the extract air duct Duct ou...

Страница 14: ...or at the very least once a year To replace the filters 1 Disconnect the ventilation unit from the mains electricity supply 2 Lift the latch to open the door of the Vallox ventilation unit 3 Lift the...

Страница 15: ...er spray Do not use a high pressure cleaner 9 When all the water has drained from between the layers reassemble the ventilation unit in the reverse order 10 When reassembling Vallox 096 MV check that...

Страница 16: ...ee chapters Replacing the filters and Cleaning the heat recovery cell 5 Pull out the temperature sensor figure 1 located at the top of the extract air duct G Remove the stopper screw I at the bottom o...

Страница 17: ...gure 9 c Pry the plastic lock to the right of the fan with a screwdriver for example figure 10 d The fan falls downwards e Pull the fan out of the unit figure 11 f Disconnect the fan wire quick connec...

Страница 18: ...5 Open the four screws figure 1 on the extract air fan cover and remove the cover figure 2 The fan can now be cleaned in place 6 To remove the fan for cleaning a Push the fan gently upward figure 3 b...

Страница 19: ...61 63 66 66 13 17 24 29 33 36 39 42 44 44 4000 17 23 34 41 47 51 55 58 61 61 17 17 18 20 23 26 29 32 34 34 8000 21 21 26 34 42 47 52 56 59 59 21 21 21 21 21 22 23 25 27 27 LW dB LWA dB A 56 65 70 75...

Страница 20: ...5 62 69 73 76 80 83 85 86 86 55 57 62 66 70 72 75 78 79 79 41 49 56 60 63 67 69 72 73 73 33 38 43 46 50 53 56 59 60 60 Sound pressure level coming through the envelope of the unit in the room in which...

Страница 21: ...44 48 50 52 53 53 2000 23 34 43 48 53 58 62 64 66 66 15 22 30 34 38 42 45 48 49 49 4000 18 23 36 44 50 55 59 62 63 63 17 17 19 23 27 31 35 38 39 39 8000 21 22 28 39 47 54 58 62 63 63 21 21 21 22 24 28...

Страница 22: ..._B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O...

Страница 23: ...r fan tacho WT 5 GND GN 6 Supply air fan PWM YE C 1 Extract air 2 Outdoor air 3 Supply air 4 Exhaust air 5 Supply air from the HR cell D LAN MB_A External Modbus A signal MB_B External Modbus B signal...

Страница 24: ...Vallox CO2 sensor External temperature sensor NTC 4K7 Digital input 1 8 different functions Digital input 2 8 different functions Ethernet connection on top of the unit RJ45 female 0 3W 1 2W 1W 1W MyV...

Страница 25: ...r NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal...

Страница 26: ...winter limit value set at the factory 5 C Cooling The supply air setpoint value for the active mode for example At home controls the pump start up The pump starts when the supply air setting is below...

Страница 27: ...alve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 K Condensing water tube Not included in the delivery...

Страница 28: ...arse filter for supply air 978044 13 Extract air outlet 985026 23 Glass tube fuse 63mA slow 5x20mm 952490 6 Fine filter for supply air 978220 14 Internal humidity and carbon dioxide sensor 4107982 24...

Страница 29: ...5 Internal humidity and carbon dioxide sensor 4107982 24 NTC sensor kit 3457900 7 Lower support for HR cell 3450100 16 Motherboard 949032 1 25 Glass tube fuse 63mA slow 5x20mm 952490 8 HR cell alumini...

Страница 30: ...wer support for HR cell 3469000 16 Motherboard 949032 1 25 Glass tube fuse 63mA slow 5x20mm 952490 8 HR cell aluminium HR cell enthalpy 933270 933154 17 Safety switch 948377 26 MyVallox Control panel...

Страница 31: ...CONFORMITY CERTIFICATES...

Страница 32: ...D5326 10 05 2023FIN 15 05 2023ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Отзывы: