background image

14

m³/h

(l/s)

dm³/s

0

50

100

150

200

250

300

350

0

10

20

30

40

50

60

70

80

90

100

0

36

72

108

144

180

216

252

288

324

360

10 %

20 %

30 %

40 %

50 %

60 %

70 %

80 % 90 %

100 %

SFP 1,8 

SFP 1,5 

SFP 1,0 

TECHNIC

AL SPECIFIC

ATIONS

FAN INPUT POWER

Input power (total) (W)

Air flow (max) (dm

3

/s)

SFP =

SFP rate (Specific Fan Power)

recommended value <1.8 (kW m

3

/s)

Volume flow rate

Power (W)

SUPPLY/EXTRACT AIR VOLUMES

Volume flow rate (dm

3

/s)

Pressure loss in ducts. Total pressure (Pa)

extract air

supply air

30 %

10 %

60 %

70 %

0

36

72

108

144

180

216

252

288

324 360 m³/h

(l/s)

dm³/s

0

20

40

60

80

100

120

140

160

180

200

0

10

20

30

40

50

60

70

80

90

100

20 %

40 %

50 %

80 %

90 %

100 %

Sound power level in the supply air duct (one duct)  

by octave band L

w

, dB

Sound power level in the extract air duct (one duct)  

by octave band L

w

, dB

Adjustment position

Adjustment position

Adjustment position (%) 10

20

30

40

50

60

70

80

90

100

10

20

30

40

50

60

70

80

90

100

Medium

frequency

of the

octave 

band

Hz

63

62

62

65

66

70

71

73

74

77

79

53

52

56

62

65

69

71

71

73

74

125

52

55

57

59

62

63

65

66

68

68

43

46

49

52

55

59

62

65

66

67

250

52

58

61

64

68

66

67

68

69

70

35

41

54

47

50

52

54

56

57

58

500

47

52

56

60

63

79

72

81

76

75

24

30

35

39

43

48

50

52

57

53

1000

39

45

50

54

58

61

63

64

66

67

20

26

31

35

38

41

44

46

48

49

2000

27

36

43

48

52

55

57

59

62

62

13

15

20

24

27

31

33

36

38

38

4000

19

26

35

41

45

50

52

54

56

57

17

17

17

18

20

23

26

28

30

31

8000

21

21

23

28

33

39

43

46

48

49

21

21

21

21

21

21

22

22

23

24

L

W

,dB 

L

WA

, dB(A)

63

64

67

70

73

80

77

82

80

81

53

53

59

62

66

69

72

72

74

76

48

53

57

61

64

76

71

78

75

74

33

36

46

43

47

50

52

55

57

57

Sound pressure level coming through the envelope of the unit in the room in which it is installed (10m² sound absorption)

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

90

100

L

pA

, dB (A)

22

25

28

32

34

36

38

43

41

41

SOUND VALUES

TECHNICAL SPECIFICATIONS

Product title

Vallox 99 MV R

Vallox 99 MV L

Product number

4114844 

4114845

Air volumes

 

Supply air

 

Extract air

92 dm

3

/s, 100 Pa

99 dm

3

/s, 100 Pa

Fans

 

Supply air

 

Extract air

0.085 kW, 0.75 A EC

0.085 kW, 0.75 A EC

Post-heating

Electrical resistor, 900 W

Electrical connection

230 V, 50 Hz, 8.6 A power plug

Pre-heating

Enclosure protection class

IP 34

Additional heating

Electrical resistor, 900 W

Heat recovery bypass

Automatic

Filters

 

Supply air

 

Extract air

ISO Coarse > 75 % + ISO ePM₁

ISO Coarse > 75 % 

Specific energy consumption (SEC)

 

in a cold climate 

 

in a temperate climate

A+

A

Operating efficiencies*

 

 

Annual efficiency

 

Supply air efficiency

 

Specific Fan Power (SFP)

76 %

81 %

1.12 kW/m

3

/h (64 dm

3

/s)

Dimensions

 (w x h x d) 

598 x 442 x 625 mm

Weight

59 kg

*Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2012.

You can calculate the sound values for each operating point with the Vallox MySelecta software.

Содержание 99 MV

Страница 1: ...Manual Model Vallox 99 MV Type 3755 Document D10813 Valid from 01 01 2022 Updated 19 06 2023 Ventilation unit MANUAL...

Страница 2: ...he Vallox Silent Klick siphon 9 Space required by the alternative Vallox Silent Klick siphon installation method elbow 9 Measuring and adjusting the air flows of the ventilation unit 9 Dimensions and...

Страница 3: ...ctrical installations and connections must be carried out only by an electrician and in compliance with local regulations WARRANTY The guarantee and liability exclude damage resulting from Inappropria...

Страница 4: ...sult in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor or...

Страница 5: ...ed automatically by using the optional carbon dioxide humidity or VOC air quality sensor When these are used ventilation remains optimal even when the dwelling is unoccupied Each user can use the week...

Страница 6: ...supply air fan 8 R model in the figure MAIN PARTS Additional heating resistor 9 Safety switch 10 Internal carbon dioxide and humidity sensor 11 Ceiling bushing for electric wires 12 Control panel 13 C...

Страница 7: ...The top edge of the white covering strip of the ceiling mounting plate can be installed against the ceiling Alternatively a concealed mounting method can be used in which case the ceiling can be 30 m...

Страница 8: ...x can be accessed The distance between the service door and the ceiling mounting plate must be around 500 mm Alternatively the cables can be fed to the rear wall between the ceiling mounting plate and...

Страница 9: ...ing tubes These can be inserted in the ducts to allow for easier ventilation adjustment NOTE The Vallox Silent Klick siphon package is delivered with the unit Installation instructions for the siphon...

Страница 10: ...re mirrored 8 Post heating resistor in front of the supply air fan 9 Additional heating resistor 10 Safety switch 11 Internal humidity and carbon dioxide sensor 12 Ceiling bushing for electric wires D...

Страница 11: ...oncentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To replace the filters 1 Disconnect the ventilation unit from the mains electricity...

Страница 12: ...e HR cell in place 13 Turn the upper support against the cell Ensure that the upper support is properly nestled against the cell remains upright 14 Install the extract air filter C and the supply air...

Страница 13: ...r feedthrough K L through the intermediate floor and to the bottom part of the unit 7 Remove the plastic screws used to fasten the fans I 2 per fan Remove the wing screws J 2 pcs of the post heating r...

Страница 14: ...7 31 33 36 38 38 4000 19 26 35 41 45 50 52 54 56 57 17 17 17 18 20 23 26 28 30 31 8000 21 21 23 28 33 39 43 46 48 49 21 21 21 21 21 21 22 22 23 24 LW dB LWA dB A 63 64 67 70 73 80 77 82 80 81 53 53 59...

Страница 15: ...r connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output T Supply air fan P Extract air fan M Damper mot...

Страница 16: ...NTC 4K7 Digital input 1 8 different functions Digital input 2 8 different functions Ethernet connection on top of the unit RJ45 female 0 3W 1 2W 1 W 1 W MyVallox VOC sensor 2W MB_A External Modbus A s...

Страница 17: ...rd MLV control External temperature sensor NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A s...

Страница 18: ...ature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Manual In summer the duct radiator will turn on when the outdoor temperature rises ab...

Страница 19: ...alve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 K Condensing water tube Not included in the delivery...

Страница 20: ...ly 4115315 22 Connection box 3526700 5 Coarse and fine filter for supply air 4114075 14 Additional heating resistor 4115412 23 MyVallox Control panel MyVallox Touch panel 949033 949090 6 Damper motor...

Страница 21: ...CONFORMITY CERTIFICATES...

Страница 22: ...22...

Страница 23: ...23 Vallox Oy All rights reserved...

Страница 24: ...D10813 19 06 2023FIN 19 06 2023ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Отзывы: