58
Troubleshooting
E24
Valve Duty Cycles
Re-Synced Due to High
Pressure
When the water pressure exceeds
the VRI Resync Pressure.
No
The machine water pres-
sure is equal to the valve
resync water pressure
setting. The valve duty cycle
is automatically resyncron-
ized.
E25
GPS Coordinates Out of
Range
• The Satellite Count
is logged with the
error.
When GPS coordinates are out of
range.
Yes, if Shut
Down System
is selected.
Verify that Distance to GPS,
or Radius -, values
are correct.
Verify that pivot point
coordinates are correct.
Crosstalk from another GPS
device on the same channel.
Change GPS PLC to
different channel to avoid
crosstalk.
E28
VDC Error Report
Message Received
When a Communication board error
report message is received.
No
An error report was gener-
ated in response to a
command.
View the Error Report in
System, Diagnostics and
Error Codes
Figure 58-1
Viewing System Error Codes
ICON1, ICON5, ICON10 and ICONX
Control Panels
To view the System Error Codes (see Figures 58-2
and 58-3) do the following:
1. Push
Menu
,
System
,
Diagnostics
,
Error
Codes
, and
System
.
2. Push
View All Errors
or
View Active Errors
to
display the Error Codes screen.
For this example, push
View Active Errors
to
view only the active errors.
Viewing an error code will clear it from the num-
ber of errors shown next to the Error icon in the
status area of the Main Screen.
3. To access the desired error code do one of the
following:
• Push the
Next
button to search forward through
the error codes.
• Push the
Previous
button to search backward
through the error codes.
Resetting Error Count
To set the Error Count to 0 (zero), push
Reset
Count
. See Figures 58-2 and 58-3.
The error count is reset to zero, and the first and
last error occurrences are set to the current time
and date.
System Error Codes (Continued)
1
Figure 58-2 ICON5 and ICONX Active Errors
1. Reset Count
1
Figure 58-3 ICON1 and ICON10 Active Errors
1. Reset Count
Содержание VRI-iS
Страница 2: ...2 This page was left blank intentionally...
Страница 44: ...This page was left blank intentionally 44 Setup...
Страница 50: ...50 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Field Install pn 9312421...
Страница 51: ...51 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Wiring Schematic pn 0999334...
Страница 52: ...52 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Field Install pn 9312419...
Страница 53: ...53 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Wiring Schematic pn 0999346...
Страница 82: ...82 Troubleshooting This page was left blank intentionally...