Valley Industries EVERFLO EFHP1011-QA Скачать руководство пользователя страница 1

    

 

 

 

Owner’s Manual 

Instructions for Assembly, Testing, Operation, Servicing, and Storage 

 

12V Diaphragm Pump

: For use with non-potable liquids such as water-based 

agricultural pesticides and other liquids** 

 

WARNING 

 

READ and UNDERSTAND the Owner’s Manual completely before using this pump

.  

Assemble, test, and use only in accordance with the Owner’s Manual instructions. 

 

READ and FOLLOW chemical safety instructions.

  Pesticides are hazardous chemicals.  

 

KNOW emergency procedures BEFORE handling chemicals.

  Pump leaks, bodily chemical 

contact, poisoning, and spills require immediate response.  

 

AVOID inhaling, ingesting, or coming into contact with any chemicals.

  

 

WEAR personal protective gear when operating, cleaning, and servicing the pump. 

 

 

KEEP pump and spray materials away from children and pets.

  Pesticides are especially 

toxic to them.  

 

DO NOT TURN ON POWER to pump until ready to spray

 in order to avoid unintentional 

spray release.  

ALWAYS

 keep a fire extinguisher rated “ABC” nearby. 

 

Improper use of the pump or handling of chemicals could result in serious injury or 
illness to the operator or nearby persons/animals, or could cause damage to the 
environment.

 

 

 

**

 This pump is recommended for use in spraying non-flammable liquids such as pesticides, water 

for plants/trees or dust control, or water-based non-flammable sealants or stains for outdoor wood 
surfaces.  This pump should not be used to transfer any product intended for human consumption. 
However, WE RECOMMEND THAT THE PUMP NOT BE USED FOR OTHER PURPOSES 
ONCE IT HAS BEEN USED FOR SPRAYING PESTICIDES.  Any chemical will leave some 
residual in the pump, even after the pump has been properly cleaned.  These residual chemicals can 
have unexpected effects on future uses.  For example, spraying water or other liquids that are 
contaminated with residual pesticide may result in unforeseen hazards to plant or animal life. 

This 

pump should not be used by people with reduced physical, sensory or mental capabilities or 
lack of experience and knowledge.

 

 
 
 

Any Questions, Comments, Problems, or Parts Orders 

Call Everflo Product Support 1-800-864-1649

ITEM NUMBER:   
EFHP1011-QA 

1.0GPM 

EFHP1015  

1.5GPM 

EFHP1015-QA 

1.5GPM 

EFHP1515  

1.5GPM 

EFHP1515-QA 

1.5GPM 

(Includes Boxed Models) 

 

SERIAL NUMBER: __________

 

Содержание EVERFLO EFHP1011-QA

Страница 1: ...als could result in serious injury or illness to the operator or nearby persons animals or could cause damage to the environment This pump is recommended for use in spraying non flammable liquids such...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...our Check and test completed assembly 11 Operation Important Safety Information Operation 12 General Chemical Safety Chemical Applicator Safety Chemical Accident Procedures Preparing the Pump for Each...

Страница 4: ...pump is NOT intended for use in spraying pesticides in dry or aerosolized form or for use with fumigants SPRAYING OTHER LIQUIDS In addition to spraying pesticides this pump may be used to spray other...

Страница 5: ...al label WEAR protective clothing eye protection and chemical resistant gloves when operating the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label EX...

Страница 6: ...rson 1 Immediately follow First Aid instructions on chemical label General procedures can include a Eyes immediately flush with water b Skin wash all contaminated skin surfaces with soap and water c C...

Страница 7: ...oduct Support at 1 800 864 1649 Part Description Model 798358 EFHP SERIES 1011 QA EFHP1011 QA 797056 EFHP SERIES 1015 EFHP1015 797008 EFHP SERIES 1015 QA EFHP1015 QA 797402 EFHP SERIES 1515 EFHP1515 7...

Страница 8: ...9 5mm Inside diameter 3 8 9 5mm Inside diameter EFHP1515 QA 3 4 Quick Connect 3 8 9 5mm Inside diameter 3 8 9 5mm Inside diameter NOTE Everflo does not recommend the use of metal fittings or rigid pi...

Страница 9: ...or with any non insulated tools If battery acid contacts skin or clothing flush immediately with water and neutralize with baking soda 2 Electrical requirements The pump should be on a dedicated indiv...

Страница 10: ...connect the pump s black wire from the negative terminal of the battery c Disconnect the pump s red wire from the positive terminal of the battery d Reconnect the vehicle battery ground wire Note Skip...

Страница 11: ...Never modify the pump design 1 Check assembly Check assembly to assure the pump is properly assembled and in safe working condition 2 Test with water Test the system for leaks with water a Fill the ta...

Страница 12: ...ng or coming into contact with the chemical Personal protective equipment ALWAYS wear protective clothing eye protection and chemical resistant gloves when operating and cleaning the pump Wear additio...

Страница 13: ...mical manufacturer Excess pesticide can be dangerous to humans damage desirable plants and contaminate soil and water sources Children pets ALWAYS exercise extra caution when spraying near areas acces...

Страница 14: ...emical label c Clothing remove contaminated clothing immediately Dispose of heavily contaminated clothing per the instructions on the chemical label for safe chemical container disposal 2 Seek medical...

Страница 15: ...materials like ground corncobs or pet litter should be spread on the spill area to soak up the pesticide The contaminated material should then shoveled into a leak proof container Do not flush the sp...

Страница 16: ...a safety hazard or poor operation of the sprayer 1 Ensure clean system Ensure the pump has been thoroughly flushed and drained of all residual chemicals from prior uses 2 Inspect repair Inspect and te...

Страница 17: ...area Clear the work area of all bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the pump WARNING ALWAYS wear personal protective equipm...

Страница 18: ...nded If the pump must be left unattended at any time a Disconnect power to the pump b Relieve system pressure 6 Discontinue use if clogged or inoperative If the pump becomes clogged or inoperative dur...

Страница 19: ...ticide is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to...

Страница 20: ...our RV antifreeze into the pump system Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze 2 Spray briefly Turn on the pump and run the...

Страница 21: ...icing your pump 2 Review troubleshoot ing table Review the Troubleshooting Table below for the type of problem you are experiencing However DO NOT attempt to repair until the steps listed below are fo...

Страница 22: ...fittings Replace cracked fittings Worn diaphragm Replace diaphragm assembly Worn valves Replace valve plate assembly Inlet Outlet tube restriction Remove restriction Incorrect voltage Check voltage 10...

Страница 23: ...previously sold Any Questions Comments Problems or Parts Orders Call Everflo Product Support 1 800 864 1649 Model Number Electrical connection Maximum amp draw Maximum flow Maximum pressure Ports Ove...

Страница 24: ...ption EF QC A12 Quick Connect x 1 2 Hose barb EF QC A34 Quick Connect x 3 4 Hose barb EF QC EL34 Quick Connect x 3 4 Hose barb elbow EF QC EL38 Quick Connect x 3 8 Hose barb elbow EF QC EL12 Quick Con...

Страница 25: ...1 798160 Motor assembly 1 2 798373 Base plate assembly 1 3 798163 Diaphragm assembly 1 4 798797 Valve plate assembly 1 5 798204 Upper housing assembly 1 6 797011 Pressure switch assembly 1 7 792140 Q...

Страница 26: ...Qty 1 791824 Motor assembly 1 2 786945 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797104 Upper housing assembly 1 6 797889 Pressure switch 26815151 1 797086...

Страница 27: ...on Qty 1 791824 Motor assembly 1 2 786945 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797105 Upper housing assembly 1 6 797889 Pressure switch 26815152 1 7970...

Страница 28: ...arranty This warranty covers parts only It will not provide for replacement of complete products due to defective parts Components not manufactured by Everflo are guaranteed by their manufacturer and...

Страница 29: ...29 This page left intentionally blank...

Страница 30: ...30 Everflo A Brand of Valley Industries 180 Lake Ave N Paynesville MN 56362 www everflopump com Made in China 798835_Rev A...

Отзывы: