1 947461
ISSUE 1
VIP-812A
DUAL NETWORKED STATION PORT
INTRODUCTION
The VIP-812A Dual Networked Station Port
allows most loop start terminal devices to be
connected to a managed IP-based LAN/WAN.
SPECIFICATIONS
Access Methods
PBX, FXO Port
POTS telephone set
Features
RJ-45 for network connection
2 RJ-11 telephone connections
4 Relays with Form C contacts
Front panel activity LED
Network activity LEDs
2
RENS
2.5mm jack for external power
Power over Ethernet (PoE) 802.3af
compatible
Dimensions/Weight
1.75 H x 6.75" W x 9.5" D
(4.45cm H x 17.15cm W x 24.13cm D)
Weight: 1.75 lbs. (0.80 kg)
Nominal Specifications
Input Impedance:
600 Ohms
Input Level:
-10dBm
Output Impedance:
600 Ohms
Output Level:
- 10dBm nominal
Relay Current:
1 AMP @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage:
24VDC
Current:
325mA
Via 802.3af (PoE) Ethernet Switch:
802.3af: Class
3
Environment
Temperature: 0 to +40° C
Humidity:
0 to 85% non-precipitating
Packing List
Qty
Item
1 VIP-812A
1 VSP
Document
2
Mounting Brackets W/ Hardware
4 Rubber
Pads
INSTALLATION
NOTE: The telephone system referred to in
this manual is the customer premise
equipment such as an electronic key system,
a PBX or a dedicated single line telephone
sets. The VIP-812A is not intended for direct
or indirect connection to the public telephone
network. When used with a customer premise
telephone system such as a key system or
PBX system, these units are interfaced to the
system via a fully protected system central
office port, which is a fully protected interface
device. Also, the host system must be
configured to disallow central office trunk
conferencing in order to prevent indirect
connection to the public network.