TECHNICAL ASSISTANCE

When trouble is reported, verify there are no broken connections.  Assistance in troubleshooting is available from the
factory.  Call (540) 427-3900 and ask for Technical Support. or call (540) 427-6000 for Valcom 24-hour Automated
Support or visit our website at 

http://www.valcom.com

.

Valcom equipment is not field repairable.  Valcom, Inc. maintains service facilities in Roanoke, VA.  Should
repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person,
and nature of the problem.  Send the unit to:

Valcom, Inc.

Repair & Return Dept.

5614 Hollins Road

Roanoke, VA  24019-5056

Содержание V-2924

Страница 1: ...d all call pages Each station can be programmed for one way or two way communication The stations may be grouped into one way page groups The system also provides the ability for a remote speaker loca...

Страница 2: ...attern Ring contact closure follows ring cycle Inhibit input Caller identification RS 232 serial printer port Control unit is internally powered battery backup compatible 1 VPB 260 per unit Override p...

Страница 3: ...and the key is pressed twice Remote Signaling Closure follows ring pattern 250 mA max 24 VDC PAGE PRIORITY It is possible for multiple inputs to request an audio connection to a speaker at the same t...

Страница 4: ...these tones Power Connections Use a cord set consisting of a minimum 18 AWG cord and grounding type attachment plug rated a minimum of 15A 250V The cord set should have the appropriate safety approval...

Страница 5: ...1 R16 R79 R80 R81 R82 R115 Handsfree Speaker to Phone Level Handsfree Phone to Speaker Level Background M usic Level External Tone Source Level All Call A djust Volum e Attendant Level Override P ort...

Страница 6: ...Emergency Enable C C Override Page Port Tip Override Page Port Ring Dry Priority Activate Dry Priority Activate Inhibit Inhibit Group 2 38 13 39 14 40 15 41 16 42 17 43 18 BK G G BK BK BR BR BK BK S S...

Страница 7: ...28 3 W GR GR W BACKGROUND MUSIC CONNECTION P7 Connecting Block P7 Connecting Block Low Level Music Source 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 INA 21 INB 21 INA 22...

Страница 8: ...32 7 34 9 Signal Out V 9927A 1 8 Com EXTERNAL TONE SOURCE USING A V 9927A NOTE External tone source requires dip switch settings to enable feature See Table 1 SW3 8 W SL SL W R O O R R BR BR R 947211...

Страница 9: ...K BL BL BK T R NOTE Global all call page requires dip switches SW 3 4 SW 3 5 be set on each V 2924 control unit to enable feature Y O O Y Y BR BR Y Y O O Y Y BR BR Y Y O O Y Y BR BR Y 947211_3 DRW P7...

Страница 10: ...1092 26 1 27 2 28 3 To Enable Feature strap must remain across pair when unit is powered CLOCK SYNC INPUT 45 20 Master Clock Y SL SL Y P7 Connecting Block Master Clock must make contact closure at 02...

Страница 11: ...F or group page Ringback tone to Attendant HF and group page SW3 3 No 15 second privacy tone to HF speaker 15 second privacy tone to HF speaker SW3 4 Priority phone controls local V 2924 only Priority...

Страница 12: ...essful Inhibit Allows the use of a single line phone A lead modified When the phone goes offhook all handsfree group and or all call pages are cancelled and the phone is connected to the attendant Ove...

Страница 13: ...it Zone Access to Individual Stations Dial Code Function 101 124 Handsfree speakers Main board during hf to zone 121 122 123 or 124 Operate relay for longer of 2 5 seconds or duration of second press...

Страница 14: ...defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the origin...

Страница 15: ...427 6000 for Valcom 24 hour Automated Support or visit our website at http www valcom com Valcom equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs...

Страница 16: ...h multiple V 2924 systems that require all call and or priority pages to be broadcast to all interconnected systems Global Priority Activate 42 17 Control pair for use with multiple V 2924 systems tha...

Отзывы: