background image

4

947305

Connections

___ 1.

Mount two 66B type punchdown blocks on
the backboard near the Control Unit
(V-2920) and Ring Down Device (V-2990)
and label the blocks per Figure 2. 

___ 2.

Connect the control unit  Tip and Ring (J1 -
W/BL, BL/W) to screw terminals 3 and 4 of
the ring down device.

___ 3.

Connect the control unit Ring contact
closure pair (J1 - W/GN, GN/W) to screw
terminals 5 and 6 of the ring down device.

___ 4.

Connect screw terminals 1 and 2 of the ring
down device to the appropriate C. O. port of
the telephone system.

___ 5.

Connect screw terminals 7 and 8 of the ring
unit to the VP-324 power supply "-" and "+"
terminals respectively.

Refer to Figure 3 for Wiring Designations.

Door Plate Connections

The following connections are for zone 10 of the
system.  Other zones will connect in the same manner
to their appropriate terminals.

__ 1.

Connect Tip of the door plate speaker to
W/BL of block J2.

__ 2.

Connect Ring of the door plate speaker to
BL/W of block J2.

__ 3.

Connect one side of the door plate switch to
R/BL of block J1.

__ 4.

Connect the other side of the door plate
switch to BL/R of block J1.

NOTE:  Two pair twisted station cable is
recommended for connections between the control
unit and the door plate speakers.  (Refer to Figure 4).

Music Connections

The output of a low level music source connects to
W/OR,OR/W on block J1 of the control unit.
NOTE:  Do not connect the output of a high
power amplifier to this input.

AC Power

Connect AC power cord after all required
connections have been accomplished.

Page and Music Level Set-Up

The control unit has volume controls for the
following functions:

 

Speaker to Phone

 

Phone to Speaker

 

All Call

 

Music One - Zones 10-19

 

Music Two - Zones 20-29

Refer to Figure 5 for user control locations.

Control Set-Up:
1.  Set up Talkback Controls
    (a)

The phone to speaker should be at a normal
listening level.

    (b)

Speaker to Phone Level:           
This is the most critical level; set the volume
at the lowest practical level.  (It is better to
set it too low than too high).

    (c)

Individual volume controls of any one-way
amplified speakers can then be adjusted for
normal listening level.

2.  All Call Level

The all call level should be set to produce
the same audio level as the phone to speaker
control.

3.  Background Music Levels

There are two volume controls provided for
background music adjustments:  Zones
10-19 and 20-29.

It is important that these two background music
controls be used to adjust music levels in the system.
Adjust these controls after all other volume controls
have been set.

Auxiliary Contacts

Refer to Table 1 for description of the various contact
closures.

Setting of Program Dip Switches

Refer to Table 2 for dip switch functions.

Содержание V-2920

Страница 1: ...on equipped with a call button to call the attendant location Components The V 2920 system consists of three components A V 2920 Control a V 2990 Ring Down Device and a VP 324 Power Supply Access PABX...

Страница 2: ...ery Unfiltered Signal Battery Numbering Plan The dialing codes are 10 to 29 and 0 for all call Auxiliary Contacts The V 2920 is equipped with 6 sets of auxiliary contact closures They are Lamp Contact...

Страница 3: ...the key on the telephone key pad after the zone has been called These contacts can be used to operate electric strike plates on doors The V 2920 provides a background music input and is designed to au...

Страница 4: ...re 4 Music Connections The output of a low level music source connects to W OR OR W on block J1 of the control unit NOTE Do not connect the output of a high power amplifier to this input AC Power Conn...

Страница 5: ...et Zone 22 Spk 36 11 37 12 38 BK BL BL BK BK O O BK BK G Sta 17 Gnd Sta 18 SW Sta 18 Gnd Sta 19 SW Sta 19 Gnd 13 39 14 40 15 G BK BK BR BR BK BK S S BK Zone 22 Ret Zone 23 Spk Zone 23 Ret Zone 24 Spk...

Страница 6: ...ty mode the zones can be used for door locations or other areas not requiring immediate response from the attendant These zones will be bumped from their place in queue and put at the end of the line...

Страница 7: ...e 29 Contact Operates when zone 29 is dialed and the key is pressed TABLE 2 DIPSWITCH FUNCTIONS SWITCH OFF POSITION ON POSITION 1 2 3 4 5 6 7 8 Normal queue sequence on zone 26 Normal queue sequence o...