background image

 

 

 

   Issue 

 

 
  
 
 

 

V-2904 

 

UNIVERSAL FOUR DOOR ANSWERING SYSTEM

 

 

 
 

 

 

 

INTRODUCTION 

The V-2904, Universal Four Door Answering 
System, when used with Valcom Door Plate 
Speakers, provides voice paging with handsfree reply 
to up to four doors from any telephone location.  The 
V-2904 initiates ring-in on the telephone system and 
sends a confirmation tone to the door speaker.  The 
individual at the phone responding to the signal will 
determine if access should be allowed.  Pressing a 
programmed code on the telephone dialpad or 
pressing the remote button will unlock the door to 
allow admission.  The V-2904 also provides an alarm 
control output to alert an unauthorized entry. 

 

• 

Reorient the receiving antenna 

 

• 

Relocate the equipment with respect to the radio 
or television 

These instructions contain the specifications and 
information necessary to install, operate and maintain 
the Universal Four Door Answering System. 

• 

Move the equipment further away from the radio 
or television 

 

• 

Plug the equipment into a different branch circuit 

FCC Notice

 

 

This equipment generates and uses radio frequency 
energy and if not installed and used properly, that is, 
in strict accordance with the instructions listed in this 
User's Manual, may cause interference to radio and 
television reception. 

NOTE:  The manufacturer is not responsible for 
any radio or TV interference caused by 
unauthorized modifications to this equipment.  
Such modifications could void the user's authority 
to operate the equipment. 

 

 

It has been tested and found to comply with the limits 
for a Class B Computing Device in accordance with 
the specifications in Subpart B of Part 15 of the FCC 
rules, which are designed to provide reasonable 
protection against such interference in a residential 
installation.  If this equipment does cause interference 
to radio or television reception, which can be 
determined by turning off the equipment and seeing if 
the interference stops, the user is encouraged to try 
and correct the interference by one or more of the 
following measures: 

SPECIFICATIONS 

Access 

• 

Electronic Key Systems 

• 

PABXs 

• 

1A2 Key Systems 

• 

Stand Alone Systems 

 
Refer to Figure 1 for a simplified block diagram of a 
typical installation. 
 

 

 
 

 1 

947304

 

Содержание V-2904

Страница 1: ...rent branch circuit FCC Notice This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the instructions listed in this User s...

Страница 2: ...alert tone Input for manual door unlock push button Built in 30Hz ring voltage generator with on off switch Ringback tone to speaker Calls can be placed On Hold Call waiting One way all call with vol...

Страница 3: ...to close Example Station 3 ring ring ring If the phone is off hook any activity the phone is involved in will be terminated and the phone will receive a momentary warble tone a station indication tone...

Страница 4: ...em is to ring when the door button is pressed Refer to Figure 3 for location ___ 6 Connect the 24VDC power supply 24VDC should be connected to pin 25 S V and Ground connected to pin 50 V S The power L...

Страница 5: ...ck Make Door 1 Unlock Stationary Door 1 Unlock Break Station 1 Handsfree Speaker 1 Tip Handsfree Speaker 1 Ring Door Button 1 Remote 1 Door Sensor 1 Ground 1 Door 2 Unlock Make Door 2 Unlock Stationar...

Страница 6: ...eaker with Pushbutton 66 Block V 1072A Handsfree Talkback 45 Ohm Speaker with Pushbutton Door 1 Unlock Make W S P 30 Door 1 Unlock Stationary S W P 5 Door 1 Unlock Break R BL P 31 NO Com Electric Stri...

Страница 7: ...ment Customer Provided Magnetic Door Switch Figure 9 Door Sensor Unauthorized Door Opening GR W P 3 66 Block Equipment Customer Provided Figure 10 Unauthorized Door Opening 24VDC Alarm To Alarm auto d...

Страница 8: ...rformed with a tone dial set The V 2904 is designed to allow the user to program its functions to meet the requirements of the specific application The V 2904 is however shipped from the factory with...

Страница 9: ...until the end of the second burst To change this default setting 1 Lift handset and hear dial tone 2 Press 1 2 3 6 on the dial pad Station Identification 3 Enter station number 1 4 or for all station...

Страница 10: ...contacts are closed when the door is closed and some are open when the door is closed By default the V 2904 uses door alarm contacts that are open when the door is closed Disable Station Alarm On powe...

Страница 11: ...door unlock Call Waiting If the phone is connected to station 1 in a conversation and station 2 attempts by pressing the door button to call in the individual at the phone will receive a call waiting...

Страница 12: ...ities in Roanoke VA Should repairs be necessary attach a tag to the unit clearly stating your company name address phone number contact person and the nature of the problem Send the unit to Valcom Inc...

Страница 13: ...defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that factory sealed units are unopened a ser...

Страница 14: ..._ Sta 2 MAC 82________ Sta 3 MAC 83________ Sta 4 MAC 84________ All Doors MAC 8 _____ 0 999 in seconds Sta 1 Sta 2 Sta 3 Sta 4 Duration of Ringing Sta 1 Sta 2 Sta 3 Sta 4 30 sec 30 sec 30 sec 30 sec...

Отзывы: