V-2003A - THREE ZONE PAGE CONTROL UNIT

V-2003AHF - THREE ZONE HANDSFREE

TALKBACK PAGE CONTROL UNIT

INTRODUCTION

The 

V-2003A

 provides telephone system access

to multiple zones (Up to 3) of one way paging
plus all call.

The 

V-2003AHF

 provides telephone system

access to multiple zones (Up to 3) of handsfree
talkback and/or one-way paging with a one-way
all call.

“WARNING:  To reduce the risk of fire or
electric shock, do not expose this equipment
to rain or moisture.”

“WARNING:  Shock Hazard - Do Not Open.”

“AVIS:  Risque de Choc Electrique ne pas
Ouvrir.”

“PELIGRO:  Corriente Electrica - No Abra.”

“CAUTION:  To reduce the risk of fire replace
only with same type 1A, 125V fuse.  1A, 125V
may be replaced by a 0.5A, 250V provided
voltage selector is set for 230V.”

“DANGER:  Afin de réduire le risque de feu,
remplacez le fusible par le même type de
fusible à 1A, 125V.  On peut utiliser un
fusible à 0.5A, 250V pourvu que le sélecteur

ď

alimentation soit fixé sur 230V.  Ne pas

ouvrir.”

“VORSICHT:  Zur verringerung von
feuergefahr die sicherung nur mit derselben
type 1A, 125V ersetzen.  Statt 1A, 125V Kann
0.5A, 250V Benutzt werden, vorausgesetzt,
die spannung ist auf 230V eingestellt.  Nicht
öffnen.”

“PELIGRO:  Para reducir el peligro de
incendio remplazarlo unicamente con un
fusible del mismo tipo 1A, 125V.  El fusible
de 1A, 125V podra ser remplazado por uno
de 0.5A, 250V si el selector de voltaje esta
puesto en 230V.  No abres.”

SPECIFICATIONS

Access Method

  Electronic Key System (C. O. Line Position)

  PABX (Loop or Ground Start Trunk)

  1A2 Key systems (400 Type Line Card

required)

  600 Ohm Page Port equipped with contact

closure and DTMF dialing capability; Page
Port must be bi-directional if using V-
2003AHF.

  Dedicated single line telephone(s)

Features of the V-2003A

  3 zones of one-way paging

  One-way all call

  Integrated power supply

  Supplies 20 Valcom power units (-24VDC, 1

Amp) for powering speaker amplifier
assemblies

  Volume Controls supplied for:

 Background 

music

 Tones

Night ring/warble tone
(Closure or 90VAC ring activated)
Time clock/single tone (Closure

activated)

  Options are dip switch programmable per

zone (Music and tones)

  Dial tone (Optional)

  (#) Button returns dial tone

  Provides audio for up to 150 Valcom

one-way speaker amplifier assemblies per
zone

Содержание V-2003A

Страница 1: ...die sicherung nur mit derselben type 1A 125V ersetzen Statt 1A 125V Kann 0 5A 250V Benutzt werden vorausgesetzt die spannung ist auf 230V eingestellt Nicht ffnen PELIGRO Para reducir el peligro de inc...

Страница 2: ...1 way 45 Ohms Talkback Output level 10dBm 1 way 1 Watt Talkback DC Output 24VDC at 1 Amp V 2003A 24VDC at 0 5 Amp V 2003AHF Nominal Power Requirements Voltage Current 115VAC 1 Amp 230VAC 0 5 Amp Batte...

Страница 3: ...onferencing in order to prevent indirect connection to the public network Electronic Key 1A2 PABX or Single Line Access When using the V 2003A V 2003AHF with an electronic key system 1A2 key system PA...

Страница 4: ...position SW1 should be in the UP position for loop start operation or in the DOWN position for ground start operation GROUND START NOTE When using ground start access a ground strap must be connected...

Страница 5: ...rated fuse is installed Connect cord set to unit via IEC 320 female connector located on one end of cord set to IEC 320 male appliance couple located on the V 2003A V 2003AHF For 115VAC use verify fu...

Страница 6: ...the 5 1K resistor placed in series and the resistor terminates on inhibit BR W Inhibit is not a feature of override tip and ring access Calls currently engaged in a meet me answer are not disturbed du...

Страница 7: ...s the validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that facto...

Страница 8: ...olt Out GNDOut Zone3 LowLevel Output Ring Zone3 LowLevel Output Tip GNDOut 24Volt Out Zone1 HandsfreeOutput Ring Zone2 HandsfreeOutput Ring Zone2 HandsfreeOutput Tip Zone3 HandsfreeOutput Tip Zone3 Ha...

Страница 9: ...ack No System Dial Tone No System Alrt Rngbk Tone No System Repeated Alert R34 R6 TONES MUSIC Switch Down is ON Position and selects option as listed J2 Male Amphenol Connector Spkr Phone Phone Spkr V...

Отзывы: