GENERAL
These instructions provide identification, installation,
operation, connection and maintenance information
for the V-119RT intercom unit.
The V-119RT is a single-path dial select
microprocessor controlled intercom unit to be used
with 1A2 Key Telephone Systems.
This paging unit has received an FCC type KX
registration and is designed to be used with FCC
registered key telephone systems. Installations may
be made by Valcom, Inc., telephone equipment
manufacturers, telephone companies, registered
telephone refurbishers, and those qualified for
installation of FCC registered systems under FCC
Rules Section 68.215.
In accordance with FCC rules with applicable tariffs,
this intercom unit may only be installed with the
authorization of the owner of the host system.
The FCC Registration Number
BAF9I7-69366-KX-N, will be listed in the affidavits
filed with the telephone company; it will also be
recorded in the system log kept by installation and
maintenance personnel. The local telephone
company is to be notified of the FCC Registration
Number when this intercom unit is installed.
This equipment generates and uses radio frequency
energy and if not installed and used properly, that is,
in strict accordance with the manufacturer's
instructions, may cause interference to radio and
television reception. It has been tested and found to
comply with the limits for a Class B computing
device, in accordance with the specifications in
Subpart J of Part 15 of the FCC Rules, which are
designed to provide reasonable protection against
such interference. If this unit does cause interference
to radio and television reception, which can be
determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient the receiving antenna.
•
Relocate the equipment with respect to the
receiver.
•
Plug the equipment into a different branch
circuit.
•
Move the equipment away from the receiver.
SPECIFICATIONS
Purpose
•
To provide 19 stations of intercom signaling to
1A2 key systems.
Applications
•
1A2 key systems
Features
•
19 stations or zones
•
Dial tone
•
Ringback tone
•
Last number dialed re-ring (tone only)
•
Conference calling on tone dial systems
•
Personal signaling (tone only)
•
Combined rotary and tone dialing
Capacity
•
The capacity of the V-119RT is 19 stations.
•
One talkpath.