VSP-V-1134
Issue 7
1
947114
V-1134
ALL CALL ONE-WAY PAGE UNIT
INTRODUCTION
These instructions provide the specifications and
information necessary to install, operate, and maintain
the V-1134, All Call One-Way Page Unit.
SPECIFICATIONS
Purpose
To provide one-way all call page to 34 zones when
used with the V-136RTHF 36 zone page control unit.
Applications
•
V-136RTHF 36 zone handsfree control unit
Features
•
One-way all call amplification to 34 zones
•
Dial 0 for all call
•
Automatic release of all call unit with two
telephones off hook
•
Easy installation - 30" plug ended cable provided
•
Built-in volume control for all call level
NOTE: Unit replaces stations 0 and 39 on 36 zone
control units.
Dimensions/Weight
•
7.13"H x 5.75"W x 2.13"D
(18.11cm H x 14.61cm W x 5.41cm D)
•
4 lbs. (1.8 kg)
Power Requirements
•
-24 Vdc B battery 1 amp maximum
Output
•
400 milliwatts per speaker
DESIGN
General
This unit provides one-way all call page to the
V-136RTHF. The functions and operation of the
intercom unit remain the same as without the all call
unit with exception that dialing "0" energizes the all
call unit and permits a one-way page to all stations of
the intercom.
INSTALLATION
Precautions
All precautions have been taken at the factory to insure
that the equipment functions properly. To insure
proper operation and to prevent equipment damage,
please observe the following:
a)
Unplug the power supply before connecting any
wires or cables to the control unit connecting
block.
b)
Do not locate the control unit more than 5 feet
from the power supply or closer than 18 inches.
c)
Do not use a lamp tester to check signals, use a
voltmeter. A lamp tester when first applied is a
short circuit to electronic circuits.
d)
Do not apply power to the control unit until all
connections have been double-checked.