Problem
Possible Cause
Possible Solution
Glue Pattern
1.
At low speed, the
pattern length is too
short or too long.
1a. Either the “flap” or the “glue”
value is incorrect.
1b. Ratio compensation is incorrect.
1a. Ensure that the “flap” and “glue”
values have been correctly
entered.
1b. Ensure that ratio compensation
has been correctly entered.
2.
At low speed, the delay
is too short or too long
before the pattern starts.
2a. “Flap” value is incorrect.
2b. Ratio compensation is incorrect.
2c. Cell-to-gun value is incorrect.
2a. Ensure that the “flap” value has
been correctly entered.
2b. Ensure that the ratio
compensation has been correctly
entered.
2c. Ensure that the cell-to-gun value
has been correctly entered.
3.
At high speed, the
pattern length is too
short or too long.
3a. Either the “flap” or the “glue”
value is incorrect.
3b. Pattern length is incorrect at low
speed.
3c. Either the on or off compensation
is incorrect.
3a. Ensure that the “flap” and “glue”
values have been correctly
entered.
3b. Ensure that the pattern length is
correct at low speed.
3c. Ensure that the on and off
compensations have been adjusted
properly.
4.
At high speed, the delay
is too short or too long
before the pattern
begins.
4a. “Flap” value is incorrect.
4b. “Flap” position is incorrect at low
speed.
4c. “On” compensation is incorrect.
4a. Ensure that the “flap” value has
been correctly entered.
4b. Ensure that the “flap” position is
correct at low speed.
4c. Ensure that the “on”
compensation has been correctly
entered.
5.
There is a drop of glue
at the end of the product
5a. Air in glue line
5b. Glue viscosity too low
5c. Defective O-ring
5d. Too much guide-spring tension
(too much product movement at the
glue station)
5a. Purge air from glue line.
5b. Increase glue viscosity to 1500-
2000 cps.
5c. Replace O-ring.
5d. Decrease guide-spring tension.
Содержание VC350A
Страница 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Страница 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Страница 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Страница 79: ...Section 10 Troubleshooting VC350A Flexoseal System Valco Cincinnati 10 9 Figure 10 2 No Glue Flowchart ...
Страница 95: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 6 Shaft Encoder Assembly 155xx001 ...
Страница 105: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 16 Mounting Bracket Assembly 578xx530 ...
Страница 107: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 18 Scanner Mounting Bracket Assembly 581xx157 ...
Страница 113: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 24 Glue Station Top Down Tab Side 578xx644 ...
Страница 115: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 26 Glue Station Bottom Up Tab Side 578xx649 ...
Страница 117: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 28 Conversion Kit Assembly 723xx003 ...
Страница 119: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 30 3 Way valve 12VDC 411xx751 ...
Страница 127: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 38 LP366WGT Low Pressure Glue Valve 705xx112 ...
Страница 129: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 40 0 40 mm 0 016 Zoll 08 Glue Valve 703xx907 ...
Страница 131: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 42 366 Glue Valve Assembly 706xx051 ...
Страница 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Страница 135: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 46 Scanner Assembly 280xx201 3 4 1 5 6 ...
Страница 139: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 50 Glue Filter 529 Small 593xx024 ...
Страница 143: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 54 DD 1 Pump 66 47 5 5 11 ...
Страница 147: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 58 Glue Regulator Option ...
Страница 159: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 70 Air Filter Regulator Assembly 594xx031 ...
Страница 161: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 72 Electrical Connectors ...
Страница 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...
Страница 182: ...Appendix A Wiring Diagrams VC350A Flexoseal System Valco Cincinnati A 3 Figure A 2 Interface Board Schematic ...
Страница 211: ...VC350AG VC350AG VC350AG VC350AG VC350AG AutoGlue Control Operations Manual Manual Number MC060 Release Date August 2005 ...