General Parameters
Parameter
Factory
Range
Info
Command
Supervisor
settings
Order
option
defined*
1 = Th Heating temperature
1 = Vh Heating voltage
1 = Vs Supply voltage
1 = Vr 3.5 V reference voltage
1 = Id Information field
0 = Reserved
0 = Reserved
0 = Reserved [& = Delimiter]
1 = Th Heating temperature
1 = Vh Heating voltage
0 = Vs Supply voltage
0 = Vr 3.5 V reference voltage
0 = Id Information field
0 = Reserved
0 = Reserved
0 = Reserved
Format:
1111000011000000
First 8 are for combined
message and last 8 for
composite message.
1 = Data is on
0 = Data is off
Note that you write the
parameter format
1111000011000000
but the unit answers:
11110000&11000000
* For the heated unit factory
the setting is
1111000011000000
and for the non-heated
0000000000000000
SU,R
Device
address
0
0 ... 9, A. ... Z, a ... z
Address identifier
XU,A
Protocol
selection
Order
option
defined
A = ASCII, automatic
a = ASCII, automatic w. crc
P = ASCII, polled
p = ASCII, polled w. crc
N = NMEA, automatic
Q = NMEA, query
S = SDI-12, R
R = SDI, continuous meas
XU,M