User’s Guide ______________________________________________________________________
152 _________________________________________________________________ M211840EN-C
WXT530 Series settings:
0IU,R=11111000&11111000,I=60,A=3.0
0IB,G=100000.0
0IS,M=1,G=1.0
0IP,A=1.0
0IA,M=M,G=0.2
Enabling and Disabling Analog
Input
If the analog input option is selected for WXT536, all analog inputs are
enabled by default.
You can enable and disable analog output with the
aIU,R=
command.
For example, PT1000 temperature enabled, all other disabled:
aIU,R=1000000010000000
You need to reset the transmitter to apply the new setting. When analog
output is in use, the serial port does not work. The service connector
functions.
For aWU setting fields, see
Table 25 aWU Setting Fields [R], on page
Common Sensor Settings (aIU)
Update Interval [I]
The update interval in seconds. This parameter defines the
measurement interval for analog inputs:
-
pt1000
-
solar radiation
-
aux rain
The range: 0.5 ... 3600