The optional WMT700 zero wind verifier (WMT70Verifier) is a small echo-free chamber for
testing the mechanical integrity of WMT700 and performing one-point calibration. The
verifier ensures that the array is undamaged and that the transducers are parallel to each
other. You can perform the verifier test also in the field.
2.4.3 Cables
Select the cables according to your operating environment.
Table 17 Cables
Order Code
Description
Purpose
WMT70Conn
Cable connector
Cable
227567SP
Cable 2 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
227568SP
Cable 10 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
237890SP
Cable 15 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
237889SP
Cable 26 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
228259SP
RS-485 cable 2 m, cable connector,
open leads on one end
Used for serial communication with RS-485
interface.
228260SP
RS-485 Cable 10 m, cable connector,
open leads on one end
Used for serial communication with RS-485
interface.
227565SP
MAWS cable 10 m
Used for connecting WMT700 to Vaisala Automatic
Weather Station MAWS.
229807SP
AWS520 cable 10 m, shield connected
to PE pin
Used for connecting WMT700 to Vaisala Fixed Site
Observation System AWS520.
227566SP
AWS520 cable 10 m, shield not
connected to PE pin
Used for connecting WMT700 to Vaisala Fixed Site
Observation System AWS520.
231425SP
ROSA analog cable 10 m, cable
connector, open leads on one end
Used for connecting WMT700 to Vaisala Road
Weather System ROSA.
227569SP
Adapter cable for WS425 serial
Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
227570SP
Adapter cable for WS425 analog
frequency output
Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
227571SP
Adapter cable for WS425 analog
voltage output
Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
ASM210719SP Junction Box with Cable 2 meters
Used when a cable longer than 10 meters is needed.
Junction Box contains terminal blocks that extend
the 2-meter cable to a needed length.
WMT700 User Guide
M211095EN-H
28
Содержание WINDCAP WMT700 Series
Страница 1: ...M211095EN H User Guide Vaisala WINDCAP Ultrasonic Wind Sensor Series WMT700 ...
Страница 17: ...Figure 4 WS425FIX60 POM 1 Clamp 2 Label Figure 5 WMT700FIX60 POM 1 Clamp 2 Label Chapter 2 Product Overview 15 ...
Страница 32: ...WMT700 User Guide M211095EN H 30 ...
Страница 100: ...WMT700 User Guide M211095EN H 98 ...
Страница 168: ...4 Remove the verifier WMT700 User Guide M211095EN H 166 ...
Страница 174: ...WMT700 User Guide M211095EN H 172 ...
Страница 182: ...WMT700 User Guide M211095EN H 180 ...
Страница 194: ...WMT700 User Guide M211095EN H 192 ...
Страница 198: ...WMT700 User Guide M211095EN H 196 ...
Страница 199: ...Appendix F WMT700 Accessories Figure 53 Complete Set of WMT700 Accessories Appendix F WMT700 Accessories 197 ...
Страница 201: ...Appendix G Certificate Appendix G Certificate 199 ...
Страница 202: ...WMT700 User Guide M211095EN H 200 ...
Страница 208: ...WMT700 User Guide M211095EN H 206 ...
Страница 209: ......
Страница 210: ...www vaisala com ...