3.9.1 Verification
The status indicator LED is located on the component board under the junction box cover.
• The LED flashes green, if the self-diagnostics are completed without errors.
• The LED flashes red, if there is an error.
An error can be caused by a sensor malfunction, an erroneous installation or configuration, or
a combination of these. To diagnose the problem, use the service command
ERRS
over the
service connection.
If WAC155 signal cable is connected to a data collection system and the system is switched on,
make sure that the wind readings react correctly:
• To test the anemometer, rotate the cups manually.
• To test the wind vane, hold the vane at a few fixed angles and verify the data.
Chapter 3 – Installation