0 1 2
3
4 5
6
7
8
9
5
1
2
3
4
6
Figure 2 GMW80 series component board parts
1
Pins connecting the transmitter cover to the screw terminals when the transmitter cover is
in place
2
Vaisala INTERCAP
â
humidity sensor (on models with the letter R)
3
Pt1000 temperature sensor for passive temperature measurement (on models with the
letter P)
4
Active temperature sensor
5
GM10 carbon dioxide measurement module
6
Rotary switch for relay setpoint (on models with the letter S)
2.1.2 GMW87 and GMW88 transmitter parts
The enclosure of the IP64-rated GMW87 and GMW88 transmitter models differs from the
other GMW80 transmitter models. In GMW87 and GMW88, the screw terminal block is located
on the cover of the enclosure instead of the mounting base. Wires are led into the enclosure
either through a cable gland on the bottom of the mounting base or a sealed lead-through at
the back. The enclosure is opened and closed with 4 screws instead of the opening tab used in
other models.