background image

Notes on the documentation

Operating instructions ecoTEC plus  0020134822_01

3

1

Notes on the documentation

The following instructions are intended to guide you 
throughout the entire documentation. Other documents 
apply in addition to these operating instructions. 
We accept no liability for any damage caused by failure to 
observe these instructions.

Other applicable documents

When operating the ecoTEC plus, you must observe all 
operating instructions that are included with other compo-
nents of your system.
These operating instructions are included with the individ-
ual components of the system.

Further instructions for all accessories and controllers used 
also apply.
The benchmark checklist for starting up gas-fired boilers 
(contained in the installation instructions) must be com-
pleted by the Health and Safety Executive-approved heating 
specialist company and/or the competent person present 
during the commissioning and must be passed on to the 
system operator. After reading through these instructions, if 
you have any questions regarding the operation of the 
boiler, please contact your recognised Health and Safety 
Executive-approved heating specialist company or Vaillant's 
technical department.

In these instructions, the heating specialist company and 
competent person approved by the Health and Safety Exec-
utive will be abbreviated as the heating specialist company 
and competent person.

1.1 Storing 

documents

 

>

Store these operating instructions and all other applica-
ble documents in such a way that they are available 
whenever required.

1.2 

Applicability of the instructions

These operating instructions apply exclusively to boilers 
with the following article numbers:

Unit

Type designation

Article number

ecoTEC plus

VU GB 806/5-5

0010010767

ecoTEC plus

VU GB 1006/5-5

0010010780

ecoTEC plus

VU GB 1206/5-5

0010010791

1.1 Type overview

To find out the article number of your boiler, refer to the 
identification plate.

1.3  

Identification plate

The identification plate of your Vaillant ecoTEC plus boiler 
is attached at the factory to the underside of your boiler.
The seventh to sixteenth digits of the serial number on the 
identification plate represent the article number.

1.4  

CE label

The CE label shows that the units comply with 
the basic requirements of the applicable direc-
tives as stated on the identification plate.

1.5 Benchmark

i

  Vaillant Ltd. supports the Benchmark Initiative. 

A benchmark checklist for commissioning floor-
standing gas-fired boilers is attached to these 
installation instructions. It is very important that 
this document be filled out properly when 
installing, commissioning and handing-over to 
the system operator.

Содержание VU GB 806/5-5

Страница 1: ...Operating instructions For the operator GB IE Operating instructions ecoTEC Gas fired wall hung high efficiency boiler...

Страница 2: ...ions of the boiler 14 4 11 Protecting the heating installation against frost 16 5 Troubleshooting 17 5 1 Reading fault messages 17 5 2 Reading fault codes 18 5 3 Detecting and rectifying faults 18 5 4...

Страница 3: ...the heating specialist company and competent person approved by the Health and Safety Exec utive will be abbreviated as the heating specialist company and competent person 1 1 Storing documents Store...

Страница 4: ...oper use or use for which it is not intended This boiler is not designed to be used by persons including children with limited mental and sensory capabilities or by persons who do not have enough expe...

Страница 5: ...of poisoning If there is a smell of flue gas in the building proceed as follows Open all accessible doors and windows fully and ensure adequate ventilation Switch the boiler off Inform a heating spec...

Страница 6: ...er s environ ment Never shut down the safety devices Do not tamper with any of the safety devices Do not make any changes to the boiler to the gas air water and electricity supply lines to the entire...

Страница 7: ...n Heating mode the boiler heats the hot water and sends it through the radiators or underfloor heating of your home heating circuit The hot water pumped into the heating cir cuit exits the boiler at a...

Страница 8: ...witches off after one minute if you do not press any button 50 F 01 1 2 3 4 8 7 6 5 4 2 DIA system with possible symbol displays 1 Display indicating the current heating flow tempera ture the filling...

Страница 9: ...herefore contributes to prolonging the life of your boiler The symbol also appears if the boiler is in a waiting period F XX Fault in the boiler Appears instead of the basic dis play section 4 4 A pla...

Страница 10: ...relevant activated function is displayed in the display If the display becomes dark the light is switched on by the first press of the button In this case to trigger the button function you must press...

Страница 11: ...e pipe 4 6 2 Switching on the boiler b Caution Material damage caused by frost Frost protection and monitoring devices are only active while the boiler is connected up to the power supply Do not isola...

Страница 12: ...um 3 or maximum water pressure 2 that is to be set appear in the display If the heating installation extends over several storeys a higher filling pressure may be required for the heating installation...

Страница 13: ...ired level or the basic display If you do not press any buttons for more than 15 minutes the display returns to the basic display 4 7 Setting the heating flow temperature 4 7 1 Setting the heating flo...

Страница 14: ...4 11 Setting the hot water temperature Press the on off switch to switch on the boiler Press the left hand selector button The hot water temperature that is set is shown flashing on the display Use th...

Страница 15: ...change by pressing the right hand selector button OK Heating mode is switched off The symbol appears on the display To switch Heating mode on again Use the plus button to set your required heating fl...

Страница 16: ...tected against frost if the heating system remains on and the rooms are sufficiently heated while you are away 4 11 1 Activating the frost protection function Your QQQQVaillant ecoTEC plus boiler is e...

Страница 17: ...0870 6060 777 to complete such work 5 1 Reading fault messages F 75 Fault Pump water shortage 5 1 Fault display Fault messages have priority over all other displays If a fault develops in the boiler...

Страница 18: ...boiler switched off Switch on the mains switch on the boiler section 4 6 2 The heating flow temperature is set too low or in the Heating off position section 4 7 2 and or the hot water temperature is...

Страница 19: ...ting installation extends over several storeys a higher filling pressure may be required for the heating installation Ask your competent person for details about this To fill up and to re fill the hea...

Страница 20: ...will switch itself off The fault message F 32 appears in the display The dis played fault code is additionally explained by a correspond ing plain text message in the display Fault Fan 6 Auxiliary fun...

Страница 21: ...nitor Information Back Select Menu Water pressure Live Monitor Information Back Select Menu Live Monitor Reset burner off time Information Back Select Information Contact data Serial number Back Selec...

Страница 22: ...and their meaning selection 6 3 Setting the display contrast Back Display contrast 20 6 4 Setting the display contrast Menu Information Display contrast Using this function you can set the display co...

Страница 23: ...n must only be operated by your competent person 7 Service a Danger Risk of injury and material damage due to incorrect maintenance and repairs If maintenance is not carried out or it is carried out i...

Страница 24: ...f the guarantee to be valid an annual service must be carried out by a competent person approved at the time by the Health and Safety Executive one year after installation The cost of this annual serv...

Страница 25: ...pumped through your heating installation The temperature of this hot water as it leaves the boiler is referred to as the heating flow tempera ture Hot water generation Your boiler heats the water in...

Страница 26: ...on 16 Draining the heating installation 16 Protecting the heating installation against frost 16 H Heating flow temperature 13 Hot water Drawing hot water 7 Setting the hot water temperature 14 Hot wat...

Страница 27: ...k Right hand selector but ton Button to Heating off Confirm OK 2 Setting the heating temperature switching on Heating mode section 4 7 1 50 50 Target flow temp Back 48 Target flow temp Cancel Ok Right...

Страница 28: ...0020134822_01 GBIE 062012 Subject to change Manufacturer Supplier...

Отзывы: