background image

Operating and installation instructions

GB, IE

Room thermostat

VR 51

Publisher/manufacturer

Vaillant GmbH

Berghauser Str. 40   D-42859 Remscheid
Tel. +49 21 91 18-0   Fax +49 21 91 18-2810
[email protected]   www.vaillant.de

Содержание VR 51

Страница 1: ...ing and installation instructions GB IE Room thermostat VR 51 Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Страница 2: ...9 3 System and product description 10 3 1 Component of the ambiSENSE system 10 3 2 Design of the product 11 3 3 Display 12 3 4 Radio operation 14 3 5 Flashing sequence of the signal LED 15 3 6 Duty c...

Страница 3: ...k 32 7 Troubleshooting 32 7 1 Detecting and rectifying faults 32 7 2 Command not confirmed 33 7 3 Resetting to factory setting 34 8 Care and maintenance 37 8 1 Caring for the product 37 8 2 Changing b...

Страница 4: ...arnings The action related warnings are classified in accordance with the severity of the pos sible danger using the following warning signs and signal words Warning symbols and signal words a Danger...

Страница 5: ...y arise You can use the room thermostat for the time controlled regulation of individual rooms Intended use includes the following observance of accompanying operating installation and servicing instr...

Страница 6: ...ment shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Danger c...

Страница 7: ...are provided in these oper ating instructions 1 3 2 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 3 3 Danger caused by a malfunction Install the product...

Страница 8: ...electronics may be damaged if you install the product in an unsuitable envi ronment Only install the product in dry dust free rooms Ensure that the product is not exposed to constant solar or heat ir...

Страница 9: ...g other applicable documents You must observe all the operating and installation instructions included with the system components 2 2 Storing documents Keep this manual and all other applica ble docum...

Страница 10: ...e solution can be configured via the VRC 700 app using a smartphone You can use the room thermostat with air humidity sensor for the time controlled regulation of the room temperature via the VRC 700...

Страница 11: ...n cycles meaning that the room temperature can be regulated even more precisely The installation takes place by screwing in or sticking the mounting plate and fasten ing in the clip on frame that is s...

Страница 12: ...ions 0020248975_01 3 1 Mounting plate 2 Clip on frame 3 Setting wheel 4 System button 5 Display 6 Room thermostat 3 3 Display i Note The background lighting for the display is switched off in standby...

Страница 13: ...020248975_01 13 3 SET MANU BOOST 9 8 7 6 1 2 3 5 4 1 Operation lock active 2 Unit for the numeric display 3 Automatic decrease active 4 Radio data transmission 5 Low battery charge 6 Boost mode active...

Страница 14: ...fore not be ruled out Interfer ences may for example be caused by switching operations electric motors or defective electrical units The range inside buildings may differ con siderably from the range...

Страница 15: ...vity Brief period of flashing orange Radio trans mission transmission attempt or configuration data is trans ferred Wait until the transmission has ended 1 x long period of lighting up green Process c...

Страница 16: ...nter the dig its of the unit number to confirm Brief period of lighting up orange after a green or red reception notification Batteries flat Replace the batteries 3 x long period of flashing red Produ...

Страница 17: ...red Dura tion Up to 12 hours This does not affect how the product works during this time 3 6 Duty cycle limit The duty cycle limit describes a legally regulated limit on the transmission time of units...

Страница 18: ...ases e g during start up or the new installation of a system increased and radio intensive pair ing processes may mean that this limit is not reached If the duty cycle limit is exceeded the signal LED...

Страница 19: ...the data plate The manufacturer hereby declares that the type of radio equipment that is described in these instructions complies with Direc tive 2014 53 EU The complete text for the EU Declaration of...

Страница 20: ...3 Micro AAA batteries 2 5 mm rawl plug 3 x 30 mm cross head screws 2 Double sided adhesive strips 1 Unit number sticker 1 Operating and installation instructions 4 Integration into the ambiSENSE syste...

Страница 21: ...t via the VRC 700 app as follows Open the VRC 700 app on the smart phone Select Settings on the bottom right Select ambiSENSE Select Add individual room compo nent Follow the installation assistant Wh...

Страница 22: ...e app to confirm or use the smart phone to scan the QR code i Note You can find the unit number and the QR code on the enclosed sticker and in the product s battery com partment Wait until the pairing...

Страница 23: ...t free room Do not install the room thermostat Close to heat sources such as radiators chimney walls television sets direct sunlight Above a cooker from which vapours and grease are released On cold w...

Страница 24: ...t into an existing switch series To install it in the clip on frame you can use either the supplied double sided adhesive strips or the supplied screws to secure the room thermostat to the wall Instal...

Страница 25: ...rating and installation instructions 0020248975_01 25 5 B A 1 2 Secure the adhesive strips 1 to the rear of the mounting plate 2 in the markings provided for that purpose Ensure that you can read the...

Страница 26: ...248975_01 5 the rear and that the clips for the mounting plate can click into the open ings on the room thermostat Remove the plastic film from the adhe sive strips Press the assembled room thermostat...

Страница 27: ...Set up Operating and installation instructions 0020248975_01 27 5 Screw mounting 2 1 3 B A Select a suitable installation site in the room...

Страница 28: ...site to each other i Note Ensure that the arrow on the front of the mounting plate is pointing upwards If required use the holes 2 for the installation on a flush mounted box Drill the pre marked hol...

Страница 29: ...cturers or you can integrate it into a multiframe The room thermostat fits into frames from the following manufacturers Berker S 1 B 1 B 3 B 7 glass ELSO Joy GIRA System 55 Standard 55 E2 E22 Event Es...

Страница 30: ...p is active Manual mode You can set the temperature on the product or by using the VRC 700 app The temperature setting is retained until the next time a manual change is implemented Press and hold the...

Страница 31: ...re should apply can be individually defined here In manual mode the temperature is retained until the next time a manual change is implemented Turn the setting wheel clockwise or anti clockwise to man...

Страница 32: ...acti vate the product s operation lock 7 Troubleshooting 7 1 Detecting and rectifying faults Conditions The room temperature does not reach the set temperature Check whether the radiator thermostats o...

Страница 33: ...ng wheel briefly once Check whether the Low battery sym bol is shown in the display Check that the batteries for the room thermostat have been correctly inserted in the battery compartment 7 2 Command...

Страница 34: ...allation instructions 0020248975_01 7 Transceiver cannot implement the com mand load failure mechanical block age etc Defective transceiver 7 3 Resetting to factory setting i Note All settings will be...

Страница 35: ...Troubleshooting Operating and installation instructions 0020248975_01 35 7 B 2 Re insert the batteries in accordance with the polarity markings and at the same time press and hold the system...

Страница 36: ...ur seconds until the signal LED starts to rapidly flash in orange 3 Release the system button 4 Press the system button again for four seconds until the signal LED lights up green 5 Release the system...

Страница 37: ...Care and maintenance 8 1 Caring for the product b Caution Risk of material damage caused by unsuitable cleaning agents Do not use sprays scouring agents detergents solvents or cleaning agents that co...

Страница 38: ...8975_01 8 8 2 Changing batteries 1 1 Remove the product from the mounting plate 2 Always change all the batteries 1 at the same time Battery type LR03 Micro AAA 3 Do not use rechargeable batteries 4 I...

Страница 39: ...ce 5 After inserting the batteries observe the flashing sequence of the signal LED Self test successful Signal LED lights up orange first and then green 6 Push the product in the clip on frame back on...

Страница 40: ...battery type when replacing batteries Dispose of used batteries in accordance with the instruc tions in this manual 8 2 2 Leaking batteries a Danger Risk of chemical burns caused by leaking batteries...

Страница 41: ...cal burns e g wear protective gloves 8 2 3 Batteries Note the battery type as described in these instructions see section Data plate Remove and insert batteries as described in these instructions see...

Страница 42: ...batteries from the product and dispose of them correctly Remove the batteries if you intend to store the product and not use it for an extended period and or to scrap it Do not short circuit the conne...

Страница 43: ...d hand in the product to a collec tion centre for old electrical or elec tronic appliances If the product contains batteries that are labelled with this mark these bat teries may contain substances th...

Страница 44: ...e 2x 1 5 V LR03 Micro AAA Current consumption 50 mA Battery life 2 years IP rating IP 20 Degree of contamina tion 2 Maximum permitted environmental temperature 0 35 C Height 86 mm 3 39 in Width 86 mm...

Страница 45: ...ing and installation instructions 0020248975_01 45 11 Parameter Value Maximum transmission power 25 mW Receiver category SRD category 2 Range outdoors 250 m 820 ft 3 in Duty cycle 1 per h 10 per h Mod...

Страница 46: ......

Страница 47: ......

Страница 48: ...opyright and may be reproduced or distributed only with the manufacturer s written consent We reserve the right to make technical changes Supplier Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1...