background image

Installation and maintenance instructions

eloSTOR plus,
eloSTOR exclusive

VEN …

AT, DE

Publisher/manufacturer
Vaillant GmbH

Berghauser Str. 40

D-42859 Remscheid

Tel. +49

21

91

18

0

Fax +49

21

91

18

2810

[email protected]

www.vaillant.de

Содержание eloSTOR exclusive

Страница 1: ...and maintenance instructions eloSTOR plus eloSTOR exclusive VEN AT DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Страница 2: ...4 3 Wall mounting the product 7 5 Installation 7 5 1 Establishing the water connection 7 5 2 Filling the product 8 5 3 Electrical installation 8 6 Start up 9 6 1 Setting the hot water temperature 9 6 2 Switching on 9 6 3 Handing the product over to the operator 9 7 Troubleshooting 9 7 1 Contacting your service partner 9 7 2 Procuring spare parts 9 8 Inspection and maintenance 10 8 1 Observing insp...

Страница 3: ... fixed and permanent location known as fixed installation Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 2 General safety information 1 2 1 Risk caused by inadequate qualifications The follow...

Страница 4: ...er connection of the product you must only use pipes that are temperature res istant up to 95 C under a pressure of 1 0 MPa 10 bar 1 2 7 Risk of material damage caused by using an unsuitable tool Use the correct tool to tighten or loosen screw connections 1 2 8 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 2 9 Material damage due to leaks Ensure that ...

Страница 5: ...ctional elements Applicability Installation above the work surface A B 1 2 3 4 1 Heating coil 2 Inner vessel 3 Overheating protection 4 Temperature sensor A Hot water outlet B Cold water inlet Applicability Installation below the work surface A B 1 2 3 4 1 Heating coil 2 Inner vessel 3 Overheating protection 4 Temperature sensor A Hot water outlet B Cold water inlet 3 2 Overview of the operator co...

Страница 6: ... turer s site 4 Set up 4 1 Checking the scope of delivery Check that the scope of delivery is complete and intact Applicability eloSTOR plus Quant ity Description 1 Product 1 Documentation records 1 Low pressure valve depending on the unit variant 1 Wall mounting base Applicability eloSTOR exclusive Quant ity Description 1 Product 1 Documentation records 1 Wall mounting base 4 2 Product dimensions...

Страница 7: ...onditions The load bearing capacity of the wall is not sufficient Ensure that wall mounting apparatus on site has a sufficient load bearing capacity Use individual stands or primary walling for example Do not wall mount the product if you cannot provide wall mounting apparatus with a sufficient load bearing capacity 5 Installation Danger Risk of scalding and or risk of material damage due to incor...

Страница 8: ...fitting Applicability eloSTOR plus When the direct electric domestic hot water cyl inder is heating up hot water may leak out of the tap as a result of thermal expansion 5 3 Electrical installation Danger Risk of death from electric shock Touching live connections may cause serious personal injury Disconnect the product from the power supply by interrupting all power supply sources Ensure that the...

Страница 9: ...water cylin der has been filled 2 Insert the mains plug into the wall socket 3 Set the temperature selector knob to E The indicator light lights up It goes out as soon as the set target temperature is reached 6 3 Handing the product over to the operator Explain to the operator how the safety devices work and where they are located Inform the operator how to handle the product Answer any questions ...

Страница 10: ...duct casing C B A 1 Undo the screw A between the hydraulic connections 2 Remove the temperature selector knob B 3 Remove the front casing C 4 When fitting the casing carry out the steps described above in reverse 8 4 Descaling the direct electric domestic hot water cylinder and electrical immersion heater 1 Check whether the inner vessel in the direct electric domestic hot water cylinder has any d...

Страница 11: ...stria GmbH Clemens Holzmeister Straße 6 1100 Wien Österreich E Mail Kundendienst termin vaillant at Internet Kundendienst http www vaillant at werkskunden dienst Telefon 05 7050 2100 zum Regionaltarif österreichweit bei Anrufen aus dem Mobilfunknetz ggf abweichende Tarife nähere Information erhalten Sie bei Ihrem Mobilnetzbetrei ber Der flächendeckende Kundendienst für ganz Österreich ist täglich ...

Страница 12: ...ominal capacity 5 l 5 l 5 l 5 l Maximum temperature at the out let 80 80 80 80 Energy saving mode 60 60 60 60 Temperature limit possible 40 60 40 60 40 60 40 60 Mixed water volume at 40 C 9 5 l 9 5 l 9 5 l 9 5 l Maximum operating pressure 0 MPa 0 bar 0 MPa 0 bar 0 MPa 0 bar 0 MPa 0 bar Product dimensions width 240 mm 240 mm 240 mm 240 mm Product dimensions depth 232 mm 232 mm 232 mm 232 mm Product...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...Telefon 05 7050 Telefax 05 7050 1199 Telefon 05 7050 2100 zum Regionaltarif österreichweit bei Anrufen aus dem Mobilfunknetz ggf abweichende Tarife nähere Information erhalten Sie bei Ihrem Mobilnetzbetreiber info vaillant at termin vaillant at www vaillant at www vaillant at werkskundendienst These instructions or parts thereof are protected by copyright and may be reproduced or distributed only ...