![Vaillant ecoTEC plus VUI Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/vaillant/ecotec-plus-vui-series/ecotec-plus-vui-series_installation-and-maintenance-instructions-manual_3063339064.webp)
64
Installation and maintenance instructions 0020308121_04
C
Installer level
Note
Since the code table is used for various products, some codes or some steps may not be visible in the installation
assistant.
Setting level
Values
Unit
Increment, select, explanation
Factory
setting
Min.
Max.
Enter access code
00
99
1 (competent person code 17)
Data overview
Current value
Installation assistant
→
Language:
Languages available for selection
Country-
specific
→
Date:
Current date
→
Time:
Current time
→
Device Specific Number (DSN)
0
250
Setting the Device Specific Number (only dis-
played in a double part replacement scenario for
the display and PCB)
→
Fill the installation with water
Check the filling pressure and, if required, top up
the heating installation.
→
Hydraulic operating mode
0
4
0: Without bypass,
Δ
p-const.
1: W/o bypass,
Δ
p-const.,kick
2: Bypass,
Δ
p-const.
3: Spread
Δ
T
4: Fixed pump stage
*
→
Adjust the available pressure
mbar
This selection depends on the setting
Hydraulic
operating mode
.
→
Spread setting
K
This selection depends on the setting
Hydraulic
operating mode
.
→
Pump stage setting
%
This selection depends on the setting
Hydraulic
operating mode
.
→
Gas type selection
0: Not selected
1: Natural gas
2: Propane 30/37 mbar
3: Special gas FR
4: Special gas GB
5: Special gas IT
6: Propane 50 mbar
7: Ls gas
Only the selection for the product in question is
shown here. If your product can be converted to
liquefied petroleum gas and liquefied petroleum
gas is selected, the corresponding stickers must
be affixed.
→
Single flue installation
Adjustment takes place automatically after the
selection is made.
Product-dependent
→
Weather-comp. control system
0:
Deactivated
1:
Activated
This function must be activated if an outdoor tem-
perature sensor is installed and there is no room
temperature control.
→
Installer contact info
Company
,
Phone number
QR service code
This is where you can use the Service App's QR
code scanner to read important unit data.
Check programmes
→
P.000 - P.008
Current value
You can find more detailed information in the
table of check programmes.
Actuator test
* Select the optimum operating point for the on-site installation.