0020308120_02 Air/flue pipe installation manual
19
▶
Slide the deflector onto the opening piece until you hear
the deflector click into place.
5.6.3.3 Adjusting the deflector
45°
45°
▶
Set the terminal to the required position.
–
The flue gas stream is directed upwards at an angle
of approx. 45° when the deflector is set in the centre
position.
–
If necessary, the deflector terminal can be rotated 45°
anti-clockwise or clockwise. These setting options
mean that the flue system can be further optimised.
5.6.4
Installing the variable terminal set (VTK)
5.6.4.1 Scope of delivery
1
2
3
4
1
87° elbow (2 x)
2
Pipe clamps (3 x)
3
Extension (1 m) without
sleeve
4
Extension (1 m) with
sleeve
–
Variable terminal set, black, article number 0020219529
–
Variable terminal set, white, article number 0020219530
5.6.4.2 Installing the variable terminal set (VTK)
A
B
1.
Release the catch between the opening piece and the
end pipe.
2.
Pull the end pipe from the opening piece.
0°
3.
Slide the first 87° elbow onto the opening piece until
you hear the 87° elbow click into place.
5.6.4.3 Installing extensions
1.
Install the flue system from the 87° elbow to the flue
outlet.
–
Begin with the extension with the sleeve. To be
able to install the second 87° elbow with the end
pipe, you must install the extension without a
sleeve last.
–
Allow expansion space of 1 cm in each sleeve.
–
Ensure that all pipe joints are absolutely leak-tight.