1 Safety
4
Installation and maintenance instructions ecoFIT sustain 0020230529_04
▶
Leave
the
building
immediately
and
ensure
that
others
do
not
enter
the
building.
▶
Notify
the
gas
supply
company
or
the
Emergency
Service
P
rovider
+44
(0)
800
111999
by
telephone
once
you
are
outside
of
the
building.
1.3.3 Risk of death from escaping flue gas
If you operate the product with an empty con-
densate trap / siphon, then flue gas may es-
cape into the room air.
▶
In order to operate the product, ensure that
the condensate trap / siphon is always full.
1.3.4 Risk of death due to blocked or
leaking flue gas routes
Installation errors, damage, tampering, imper-
missible installation sites or similar can cause
flue gas to escape and result in a risk of pois-
oning.
What to do if you smell flue gas in the prop-
erty:
▶
Open all accessible doors and windows
fully to provide ventilation.
▶
Switch off the product.
▶
Check the flue gas routes in the product
and the flue gas diversions.
1.3.5 Risk of death due to explosive and
flammable materials
▶
Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).
1.3.6 Risk of death from electric shock
There is a risk of death from electric shock if
you touch live components.
Before commencing work on the product:
▶
Disconnect the product from the power
supply by switching off all power supplies
at all poles (electrical partition with a con-
tact gap of at least 3 mm, e.g. fuse or cir-
cuit breaker).
▶
Secure against being switched back on
again.
▶
Check that there is no voltage.
1.3.7 Risk of death due to lack of safety
devices
The basic diagrams included in this docu-
ment do not show all safety devices required
for correct installation.
▶
Install the necessary safety devices in the
installation.
▶
Observe the applicable national and inter-
national laws, standards and directives.
1.3.8 Risk of poisoning and burns caused
by escaping hot flue gases
▶
Only operate the product if the air/flue pipe
has been completely installed.
▶
With the exception of short periods for
testing purposes, only operate the product
when the front casing is installed and
closed.
1.3.9 Risk of being burned or scalded by
hot components
▶
Only carry out work on these components
once they have cooled down.
1.3.10 Risk of injury due to the heavy weight
of the product
▶
Make sure that the product is transported
by at least two people.
1.3.11 Risk of poisoning due to missing flue
gas monitoring device
Flue gases may escape into the installa-
tion room under unfavourable conditions. If
this happens, the flue gas monitoring device
switches the heat generator off. If a flue gas
monitoring device has not been installed, the
heat generator will continue to run.
▶
Never decommission the flue gas monitor-
ing device.
1.3.12 Risk of poisoning caused by
insufficient combustion air supply
Condition
: Open-flued operation
▶
Ensure that the air supply to the product's
installation room is permanently unobstruc-
ted and sufficient in accordance with the
relevant ventilation requirements.