8
Installation Instructions
for Control Center VR 65
5.2
Installing the VR 65 with two 2-port valves
• Wire up the Control Center as shown in fig. 5.3.
• Connect the eBUS terminals of the VR 65 to the eBUS
terminals of the heating appliance using a two-core
cable. The polarity of the eBUS cable can be mixed.
The eBUS can be branched at any part of the system.
The Control Center VR 65 requires its own 230 V mains
supply via a switched fused spur.
The boiler also requires a 230 V supply.
Note!
The VR 65 has a mains switch (see fig. 4.2) to
isolate the internal electronics as well as all
connected zone valves for the purposes of tests
and maintenance. When the housing cover has
been removed, a green LED indicates if the
VR 65 is still connected to the mains voltage.
CYL.
USE
DO NOT
230 V~
N L
CH
DHW
M
M
EAR
TH
BL
UE
BR
O
W
N
BL
UE
BR
O
W
N
2-
P
o
rt
DHW
on
N
CH
DHW
N on
on
off
BUS
+
-
2
1
NTC
EAR
T
H
* NTC (for use with
Vaillant uniSTOR only)
* Cylinder
thermostat
* Note: With Vaillant uniSTOR - use either the cylinder thermostat or the NTC
optional
(VRT 360 or
VRC 400)
VR 65
Vaillant
ecoTEC
230 V wires
eBUS (24 V)
optional (24 V)
230 V~
230 V~
Connection of Control Center
Fig. 5.3 Connection with two 2-port valves
5 Electrical installation