Fig. 5.12 Attaching the pipe coupling
• Remove the plugs from the openings.
• Insert the pipe couplings into the opening
up to the stop (
1
).
• Slide the clamp in the rail of the open-
ing (
2
).
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot on the pipe coupler (B).
1
2
1
2
a
A
B
Fig. 5.13 Mounting other collectors
• Place the next collector on the lower
mounting rail.
• Slide the collector on the first collector (
1
)
and fix the hydraulic connectors with the
clamps (
2
).
• Tighten both clamping elements of the first
collector.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot on the pipe coupler (B).
1
2
3
4
Fig. 5.14 Mounting the hydraulic connections (1 - 5 collectors)
• Connect the supply (outlet with opening for
collector sensor) (
1
) on top.
• Insert the collector sensor into the open-
ing.
• Connect the return (inlet) (
2
) at the bot-
tom.
• Mount the plug without vent (
3
) in the
lower part of the collector.
• Mount the plug with vent (
4
) in the highest
position.
• Fix connections and plugs with the clamps.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
Flat roof installation 5