0020297933_07 Installation and maintenance instructions
67
5.4
Complying with minimum clearances
▶
To guarantee sufficient air flow and to facilitate mainten-
ance work, observe the minimum clearances that are
specified.
▶
Ensure that there is sufficient room to install the hydraulic
lines.
Validity:
Floor installation OR Flat roof installation
A
D
B
E
C
Minimum clear-
ance
Heating mode
Heating and cooling
mode
A
100 mm
100 mm
B
1000 mm
1000 mm
C
200 mm
250 mm
D
500 mm
500 mm
E
600 mm
600 mm
Validity:
Wall-mounting
F
A
D
B
E
C
Minimum clear-
ance
Heating mode
Heating and cooling
mode
A
100 mm
100 mm
B
1000 mm
1000 mm
C
200 mm
250 mm
D
500 mm
500 mm
E
600 mm
600 mm
F
300 mm
300 mm
5.5
Conditions for the installation type
The product is suitable for the following installation types:
Ground installation, wall installation and flat-roof installation.
The pitched-roof installation is not permitted.
5.6
Selecting the installation site
Danger!
Risk of injury due to ice formation.
The air temperature at the air outlet is below
the outdoor temperature. This can lead to ice
formation.
▶
Select a site and an orientation at which
the air outlet is at least 3 m away from
walkways, plastered surfaces and down-
pipes.
▶
Note that installation in sinks or areas that do not allow
free outflow of air is not permitted.
▶
If the installation site is in the immediate vicinity of the
coastline, ensure that the product is protected against
spraying water by an additional protection device.
▶
Keep away from flammable substances or flammable
gases.
▶
Keep away from heat sources.
▶
Do not expose the outdoor unit to dirty, dusty or corrosive
air.
▶
Keep away from ventilation openings or ventilation ducts.
▶
Keep away from deciduous trees and shrubs.
▶
Please note that the installation site must be below
2000 m above sea level.
▶
Select an installation site that is as far away from your
own bedroom as possible.
▶
Please note the noise emissions. Select an installation
site that is as far away from the windows of adjacent
building as possible.
▶
Select an installation site that is easily accessible so that
maintenance and service work can be carried out.
▶
If the installation site is adjacent to a vehicle shunting
area, protect the product using ram protection.
Validity:
Floor installation
▶
Avoid choosing an installation site that is in the corner of
a room, between walls or between fences.
▶
Prevent the return intake of air from the air outlet.
▶
Ensure that water cannot collect on the subsoil.
▶
Ensure that the subsoil can absorb water well.
▶
Plan a bed of gravel and rubble for the condensate dis-
charge.