Appendix

30

Installation and maintenance instructions atmoMAG 0020271929_00

MAG 114/1 G(P-CH)

MAG 144/1 G(E-BE)

MAG 144/1 G(H-AT)

MAG 144/1 G(H-
DE/CH)

CO

content at min. heat output

2.70 %

2.60 %

2.60 %

2.60 %

Max. flue gas mass flow rate

6.40 g/s

10.53 g/s

10.53 g/s

10.53 g/s

Min. flue gas mass flow rate

1.78 g/s

2.99 g/s

2.99 g/s

2.99 g/s

MAG 144/1 G(LL-
DE)

MAG 144/1 G(P-BE)

MAG 144/1 G(P-CH)

Gas flow rate at max. heat output

2.92 m

³

/h

2.92 m

³

/h

2.92 m

³

/h

Gas connection pressure

1.7 … 2.5 kPa
(17.0 … 25.0 mbar)

1.7 … 2.5 kPa
(17.0 … 25.0 mbar)

1.7 … 2.5 kPa
(17.0 … 25.0 mbar)

Number of burner jets

28

28

28

Burner jet

0.85 mm

0.85 mm

0.85 mm

Burner pressure

1.38 kPa
(13.80 mbar)

1.38 kPa
(13.80 mbar)

1.38 kPa
(13.80 mbar)

Air requirement for combustion at
max. heat input

50.24 m

³

/h

50.24 m

³

/h

50.24 m

³

/h

Air requirement for combustion at
min. heat input

40.55 m

³

/h

40.55 m

³

/h

40.55 m

³

/h

CO

content at max. heat output

6.20 %

6.20 %

6.20 %

CO

content at min. heat output

2.60 %

2.60 %

2.60 %

Max. flue gas mass flow rate

10.53 g/s

10.53 g/s

10.53 g/s

Min. flue gas mass flow rate

2.99 g/s

2.99 g/s

2.99 g/s

Technical data

Natural gas G25

Applicability:

Germany

MAG 114/1 G(H-
DACH)

MAG 114/1 G(LL-
DE)

MAG 144/1 G(H-
DE/CH)

MAG 144/1 G(LL-
DE)

Gas flow rate at max. heat output

2.67 m

³

/h

2.67 m

³

/h

3.36 m

³

/h

3.36 m

³

/h

Gas connection pressure

1.8 … 2.5 kPa
(18.0 … 25.0 mbar)

1.8 … 2.5 kPa
(18.0 … 25.0 mbar)

1.8 … 2.5 kPa
(18.0 … 25.0 mbar)

1.8 … 2.5 kPa
(18.0 … 25.0 mbar)

Burner jet

1.00 mm

1.00 mm

1.02 mm

1.02 mm

Burner pressure

0.97 kPa

0.97 kPa

1.05 kPa

1.05 kPa

Air requirement for combustion at
max. heat input

36.95 m

³

/h

36.95 m

³

/h

50.06 m

³

/h

50.06 m

³

/h

Air requirement for combustion at
min. heat input

30.00 m

³

/h

30.00 m

³

/h

39.73 m

³

/h

39.73 m

³

/h

CO

content at max. heat output

6.50 %

6.50 %

6.10 %

6.10 %

CO

content at min. heat output

2.70 %

2.70 %

2.60 %

2.60 %

Max. flue gas mass flow rate

7.46 g/s

7.46 g/s

12.83 g/s

12.83 g/s

Min. flue gas mass flow rate

2.13 g/s

2.13 g/s

3.58 g/s

3.58 g/s

Technical data

Natural gas G25

Applicability:

Belgium

MAG 114/1 G(E-
BE/FR)

MAG 114/1 G(P-
BE/FR)

MAG 144/1 G(E-BE)

MAG 144/1 G(P-BE)

Gas flow rate at max. heat output

2.50 m

³

/h

2.50 m

³

/h

3.17 m

³

/h

3.17 m

³

/h

Gas connection pressure

2.0 … 3.0 kPa
(20.0 … 30.0 mbar)

2.0 … 3.0 kPa
(20.0 … 30.0 mbar)

2.0 … 3.0 kPa
(20.0 … 30.0 mbar)

2.0 … 3.0 kPa
(20.0 … 30.0 mbar)

Number of burner jets

24

24

28

28

Burner jet

0.85 mm

0.85 mm

0.85 mm

0.85 mm

Burner pressure

14.8 mbar

14.8 mbar

18.5 mbar

18.5 mbar

Air requirement for combustion at
max. heat input

39.9 m

³

/h

39.9 m

³

/h

52.5 m

³

/h

52.5 m

³

/h

Air requirement for combustion at
min. heat input

31.1 m

³

/h

31.1 m

³

/h

41.6 m

³

/h

41.6 m

³

/h

Содержание armoMAG 4/1 G Series

Страница 1: ...n and maintenance instructions atmoMAG MAG 4 1 G AT BE de CH de DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www...

Страница 2: ...setting the water flow rate 13 6 3 Gas conversion 13 6 4 Checking that the flue gas sensor works correctly 13 6 5 Checking the gas flow pressure 14 6 6 Checking leak tightness 15 6 7 Handing the prod...

Страница 3: ...other system compon ents installing and fitting the product in accord ance with the product and system approval compliance with all inspection and main tenance conditions listed in the instruc tions...

Страница 4: ...combustion and room air Sprays solvents chlorinated cleaning agents paint adhesives ammonia com pounds dust or similar substances may lead to corrosion on the product and in the flue system Ensure tha...

Страница 5: ...ing regulations and or OIB Austrian Institute of Construc tion Engineering directives Applicability Switzerland The gas fired instantaneous water heater must only be installed by a competent per son w...

Страница 6: ...e data plate The data plate is mounted at the front of the down draught diverter under the product casing at the factory Applicability Germany OR Austria OR Belgium OR Switzerland Information on the d...

Страница 7: ...applicable directives as stated on the identification plate The declaration of conformity can be viewed at the manufac turer s site 4 Set up 4 1 Checking the scope of delivery 1 Remove the product fr...

Страница 8: ...0 mm B 180 mm optimum approx 250 mm C 20 mm optimum approx 50 mm D 500 mm in front of the heat generator to enable easy access for maintenance work may be provided by an opening door It is not necessa...

Страница 9: ...270 172 5 50 26 259 115 113 61 4 min 20 120 min 20 110 224 617 48 A 557 579 680 616 Height dimension A Germany Austria Belgium Switzerland MAG 114 1 G E BE FR 658 mm MAG 114 1 G H DACH 658 mm 658 mm...

Страница 10: ...270 172 5 50 26 259 124 141 61 4 min 20 120 min 20 133 5 224 617 48 A 493 679 680 616 Height dimension A Germany Austria Belgium Switzerland MAG 114 1 G E BE FR 658 mm MAG 114 1 G H DACH 658 mm 658 m...

Страница 11: ...ring capacity of the wall 2 Note the total weight of the product 3 Only use fixing material that is permitted for the wall 4 If required ensure that mounting apparatus on site has sufficient load bear...

Страница 12: ...e liquid gas tank has been purged properly before installing the product If required contact the filler or the liquid gas supplier 5 3 Using the correct gas type Using the incorrect gas type may cause...

Страница 13: ...e with the value specified in the technical data At initial start up After replacing the micro switch 1 2 If the measured value exceeds the value specified in the technical data set the flow rate at t...

Страница 14: ...by opening the hot wa ter tap again and switch the product on and off again by pressing the main switch 1 a second time If resetting does not work or the product is repeatedly blocked by a safety devi...

Страница 15: ...ly displayed by the LED indicator light Use the table that is included in the appendix to eliminate the fault After each time you eliminate a fault check that the flue gas sensor is working without an...

Страница 16: ...uct C A B D 5 Disconnect the plug connection in the cable for the gen erator 6 Unscrew the union nuts from the water valve Remove the clip from the cold water connection on the burner 7 Remove the pip...

Страница 17: ...e dirty components using a soft brush leaving the installation room to do so and replace any dam aged components if required 3 Check whether the burner jets are blocked If a jet is blocked carefully r...

Страница 18: ...ing cleaning agent to a container of hot water 4 Use a commercial descaler to remove any limescale while taking into consideration the corresponding docu mentation 5 Rinse the heat exchanger under run...

Страница 19: ...s flow value at nominal heat input in the tables of gas settings in the appendix Note Deviations of 5 are permitted Conditions The deviation is greater than 5 Check whether the correct burner jets hav...

Страница 20: ...w the sealing screw from the test nipple 1 for the burner pressure 4 Connect a U tube manometer resolution at least 0 1 bar Caution Risk of a gas leak The adjusting screw seals the gas valve as sembly...

Страница 21: ...s 11 Customer service Applicability Austria Vaillant Group Austria GmbH Clemens Holzmeister Stra e 6 1100 Wien sterreich E Mail Kundendienst termin vaillant at Internet Kundendienst http www vaillant...

Страница 22: ...ck on again 11 Setting the domestic hot water function 12 Handing over the operating instructions to the customer B Troubleshooting Symptom Possible cause Measure The product does not work The LED doe...

Страница 23: ...el on the data plate DE 2E AT CH 2H G20 2 kPa 20 mbar DE 2LL G25 2 kPa 20 mbar DE AT CH 3P DE AT G31 5 kPa 50 mbar CH G31 3 7 kPa 37 mbar Factory setting G20 G25 G31 Burner jets label 11 4 1 14 4 1 11...

Страница 24: ...14 4 1 Natural gas 2E G20 38 3 48 7 Natural gas 2E G25 41 7 52 8 Liquid gas 3P G31 14 8 18 8 Burner pressure Gas family Burner pressure for nominal heat input 11 4 1 14 4 1 Natural gas 2E G20 1 12 kPa...

Страница 25: ...1 G LL DE OR MAG 144 1 G P BE OR MAG 144 1 G P CH 3 2 1 4 5 6 7 8 9 10 11 12 13 14 15 18 16 17 1 Gas valve assembly 2 Micro switch 3 Monitoring electrode 4 Ignition electrode 5 Burner 6 Transparent c...

Страница 26: ...the product incl domestic hot water gener ation Annually 11 Checking leak tightness Annually 15 12 Checking the heat input Annually 19 13 Check the flame pattern Flames must not touch the heat exchang...

Страница 27: ...est symbol registration no 1008CS3137 1008CS3137 1008CS3137 1008CS3137 MAG 144 1 G LL DE MAG 144 1 G P BE MAG 144 1 G P CH Designated country designation in accordance with ISO 3166 EN BE CH Approved...

Страница 28: ...0 l min 6 5 14 0 l min 6 5 14 0 l min Max heat input in relation to the net calorific value Hi 21 7 kW 21 7 kW 27 7 kW 27 7 kW Min heat input Qmin 7 6 kW 7 6 kW 9 7 kW 9 7 kW Max heat output Pmax 18...

Страница 29: ...n pressure 1 7 2 5 kPa 17 0 25 0 mbar 1 7 2 5 kPa 17 0 25 0 mbar 1 7 2 5 kPa 17 0 25 0 mbar 1 7 2 5 kPa 17 0 25 0 mbar Number of burner jets 24 24 24 24 Burner jet 0 85 mm 0 85 mm 0 85 mm 0 85 mm Burn...

Страница 30: ...CH MAG 144 1 G LL DE Gas flow rate at max heat output 2 67 m h 2 67 m h 3 36 m h 3 36 m h Gas connection pressure 1 8 2 5 kPa 18 0 25 0 mbar 1 8 2 5 kPa 18 0 25 0 mbar 1 8 2 5 kPa 18 0 25 0 mbar 1 8 2...

Страница 31: ...ent for combustion at max heat input 38 3 m h 38 3 m h 38 3 m h 49 84 m h Air requirement for combustion at min heat input 28 9 m h 28 9 m h 28 9 m h 38 04 m h CO content at max heat output 7 30 7 30...

Страница 32: ...45 0 mbar 2 5 4 5 kPa 25 0 45 0 mbar Number of burner jets 24 24 28 28 Burner jet 0 5 mm 0 5 mm 0 51 mm 0 51 mm Burner pressure 31 7 mbar 31 7 mbar 34 5 mbar 34 5 mbar Air requirement for combustion a...

Страница 33: ...ue gas monitoring device 4 Flue gas pipe installed 5 Flue gas route 4 Front casing closed 5 Frost 4 G Gas connection 12 Gas type 12 H Handing the product over to the operator 15 Heat exchanger 18 I If...

Страница 34: ......

Страница 35: ......

Страница 36: ...ienst Service apr s vente Klantendienst 2 3349352 info vaillant be www vaillant be Vaillant GmbH Schweiz Suisse Svizzera Riedstrasse 12 CH 8953 Dietikon Tel 044 74429 29 Fax 044 74429 28 Kundendienst...

Отзывы: